GB/T 30940-2014Determination of tretinoin and isotretinoin in cosmetics - High performance liquid chromatography (English PDF)
化妆品中禁用物质维甲酸、异维甲酸的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 30940-2014 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 8, 2014
Implementation date
November 1, 2014
Scope
GB/T 30940-2014 is the English-translated version of 化妆品中禁用物质维甲酸、异维甲酸的测定 高效液相色谱法.
GB/T 30940-2014 is the Chinese standard "Determination of tretinoin and isotretinoin in cosmetics - High performance liquid chromatography". Its scope clause reads: This standard specifies the method for the determination of retinoic acid and isotretinoin in cosmetics by liquid chromatography.
This standard applies to the determination of retinoic acid and isotretinoin in skin care cosmetics. The detection limit of this standard for retinoic acid and isotretinoin is 1.0 mg/kg, and the limit of quantification is 3.0 mg/kg.
Its clauses include method summary; reagents and materials; apparatus and equipment; analysis steps; result calculation; limit of detection and limit of quantification; recovery rate and precision; allowable difference.
Found what you need?
Document preview — GB/T 30940-2014
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Method summary
- 4 Reagents and materials
- 4.1 Methanol. chromatographically pure.
- 4.2 Glacial acetic acid.
- 4.3 Dichloromethane.
- 5 Apparatus and equipment
- 5.1 Analytical balance. Sensitivity 0.0001g.
1 Scope
This standard specifies the method for the determination of retinoic acid and isotretinoin in cosmetics by liquid chromatography.
This standard applies to the determination of retinoic acid and isotretinoin in skin care cosmetics.
The detection limit of this standard for retinoic acid and isotretinoin is 1.0 mg/kg, and the limit of quantification is 3.0 mg/kg.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
3 Method summary
Using methanol as solvent, ultrasonic extraction, centrifugation, 0.45µm organic filter membrane filtration, liquid chromatography detection, external standard method for quantification.
4 Reagents and materials
Unless otherwise specified, the reagents used are of analytical grade, and the water is the first grade water specified in GB/T 6682.
4.1 Methanol
chromatographically pure.
4.2
Glacial acetic acid.
4.3
Dichloromethane.
4.4 Standard stock solution of retinoic acid
accurately weigh 0.01g of retinoic acid, accurate to 0.0001g, and add an appropriate amount of retinoic acid to a 50mL brown volumetric flask.
The alcohol was dissolved by ultrasonic, and the volume was adjusted to the mark with methanol to obtain a standard stock solution with a concentration of retinoic acid solution of.200 mg/L. Refrigerator protects from light
Save it and use it for 2 months.
4.5 Isotretinoin standard stock solution
accurately weigh 0.01g isotretinoin, accurate to 0.0001g, and place it in a 50mL brown volumetric flask.
Dissolve the volume of methanol ultrasonically, and dilute to volume with methanol to obtain a standard stock solution with a concentration of.200 mg/L of isotretinoin solution. Refrigerator to avoid light and cold
It can be used for 2 months in storage.
4.6 Standard working solution
Pipette the above two standard stock solutions (4.4) and (4.5) respectively, and use methanol to make 0.15mg/L~50.0mg/L
The mixed standard working solution is ready to use.
4.7
The CAS number, molecular formula, relative molecular mass and structural formula of retinoic acid and isotretinoin are shown in Table A.1 of Appendix A.
5 Apparatus and equipment
5.1 Analytical balance
Sensitivity 0.0001g.
5.2
High performance liquid chromatograph with diode array detector.
5.3
Ultrasonic cleaner.
5.4
Centrifuge.
5.5 Graduated centrifuge tube
10mL.
6 Analysis steps
6.1 Sample preparation
Weigh 0.5g of cosmetic sample (accurate to 0.001g) into a 10mL graduated test tube, add methanol and dilute to the mark, vortex and shake
Swing until the sample is evenly dispersed, ultrasonically extract for 10min, 6500r/min, centrifuge for 10min, filter the supernatant through a 0.45µm filter membrane, and filter the filtrate
To be tested.
6.2 Determination
6.2.1 Reference conditions for liquid chromatography
The reference conditions for liquid chromatography determination are as follows.
a) Chromatographic column type. C18 column (250mm×4.6mm particle size. 5µm); or chromatographic column with equivalent performance;
b) Sample injection volume. 10µL;
c) Mobile phase. A. 0.5% glacial acetic acid methanol solution (5mL glacial acetic acid added to 1000mL methanol); B. 0.5% glacial acetic acid aqueous solution (Add 5mL glacial acetic acid to 1000mL water);
d) Mobile phase flow rate. 1.0mL/min;
e) Measurement wavelength. 358nm;
f) See Table 1 for gradient elution conditions.
Table 1 Gradient elution conditions
6.2.2 Determination
Use the prepared standard working solution (4.6) to draw a standard working curve, and use the standard working curve to quantify the sample, which exceeds the linear range
Then it should be diluted and then injected for analysis. Refer to Figure B.1 and Figure B.2 in Appendix B for the chromatogram and spectrum of the reference material.
7 Result calculation
The content of the component to be tested in the sample is calculated according to formula (1).
8 Limit of detection and limit of quantification
The detection limit of this standard for retinoic acid and isotretinoin is 1.0 mg/kg, and the limit of quantification is 3.0 mg/kg.
9 Recovery rate and precision
The additive concentration is in the range of 3mg/kg~1000mg/kg, the recovery rate of addition is between 90%~105%, and the relative standard deviation is small
Less than 10%.
10 allowable difference
The absolute difference between two independent determination results obtained under repeated conditions shall not exceed 10% of the arithmetic mean.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 30940-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 30940-2014
$145.00