Scope

GB/T 30925-2014 is the English-translated version of 塑料 乙烯-乙酸乙烯酯共聚物(EVAC)热塑性塑料 乙酸乙烯酯含量的测定.

GB/T 30925-2014 — This standard specifies the determination of ethylene - Test methods vinyl acetate content of the vinyl acetate copolymer (EVAC). This standard specifies test methods, including reference methods and test methods.

Wherein the reference method for ethylene - vinyl acetate copolymer Calibration vinyl acetate content of the test method. After the test methods specified in this standard with the reference method for calibration, such as acceptable reproducibility of test results, you can use the test method Determination of vinyl acetate content.

This standard specifies the test methods in infrared spectroscopy applied to vinyl acetate content of not less than 3% of EVAC samples. NOTE. ethylene - vinyl acetate copolymer is abbreviated EVAC often use EVA.

Found what you need?

Document preview — GB/T 30925-2014

National Standard of the People's Republic of China

ICS
83.080.20
Classification
G 31

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Baseline methodology
  • 3.1 Reference Method 1. Hydrolysis - back titration

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

This standard uses redrafted law revision using ISO 8985:1998 "Plastics ethylene - vinyl acetate copolymer (EVAC) thermoplastics Determination of plastic vinyl acetate ester content. " this standard and ISO 8985:1998 technical differences are as follows.

--- Modify the test range infrared spectroscopy vinyl acetate content by not less than 10% to not less than 3% (see Chapter 1);

--- Increased infrared spectroscopy for ethylene content calculated absorption 720cm-1,2020cm-1 (see 4.1.1);

--- Modified infrared spectroscopy test equipment, infrared spectrometer to Fourier transform infrared spectrometer (see 4.1.2.1);

--- Modified infrared spectroscopy instrument wave number range from 4000cm-1 ~ 600cm-1 to 4000cm-1 ~ 400cm-1 (See 4.1.2.1);

--- Infrared spectroscopy modified test procedure, the test procedure according to a Fourier transform infrared spectrometer operation (see 4.1.3.2);

--- Modified infrared spectroscopy and infrared spectra of the example in Figure absorbance is calculated (see 4.1.3.2.5);

--- Modified infrared spectroscopy calibration curve example (see 4.1.3.3).

The standard proposed by China Petroleum and Chemical Corporation.

This standard by the National Standardization Technical Committee of plastic resins and petrochemical plastics Technical Committee (SAC/TC15/SC1) technology Centralized.

1 Scope

This standard specifies the determination of ethylene - Test methods vinyl acetate content of the vinyl acetate copolymer (EVAC).

This standard specifies test methods, including reference methods and test methods. Wherein the reference method for ethylene - vinyl acetate copolymer Calibration vinyl acetate content of the test method.

After the test methods specified in this standard with the reference method for calibration, such as acceptable reproducibility of test results, you can use the test method Determination of vinyl acetate content.

This standard specifies the test methods in infrared spectroscopy applied to vinyl acetate content of not less than 3% of EVAC samples.

NOTE. ethylene - vinyl acetate copolymer is abbreviated EVAC often use EVA.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 28212-2011 laboratory glassware condenser

3 Baseline methodology

3.1 Reference Method 1. Hydrolysis - back titration

3.1.1 Principle

The sample was dissolved in xylene, was added potassium hydroxide - ethanol solution so that the hydrolysis of the acetate group. Then adding excess sulfuric acid or hydrochloric acid, to Phenolphthalein as an indicator, with sodium hydroxide standard solution titrate the excess acid.

3.1.2 Reagents

Analysis using analytical reagent.

3.1.2.1 xylene.

3.1.2.2 sulfuric acid concentration of about 5g/L, or hydrochloric acid, a concentration of about 3.7g/L.

3.1.2.3 KOH - ethanol, a concentration of about 5.6g/L.

The solid was 5.6g of potassium hydroxide was dissolved in 500mL of ethanol, and then diluted to 1000mL. After standing for 24h, supernatant.

3.1.2.4 standard sodium hydroxide solution, c (NaOH) = 0.1mol/L.

3.1.2.5 phenolphthalein indicator. 0.7g of phenolphthalein was dissolved in 100mL of ethanol.

3.1.3 Instruments

Usual laboratory equipment and the following.

3.1.3.1 Buret capacity 50mL.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 30925-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 30925-2014

$235.00