Valid

GB/T 30842-2014Electromagnetic shielding effectiveness specification and measuring method for high voltage testing enclosures (English PDF)

高压试验室电磁屏蔽效能要求与测量方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for GB/T 30842-2014 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 6, 2014

Implementation date

January 22, 2015

Scope

GB/T 30842-2014 is the English-translated version of 高压试验室电磁屏蔽效能要求与测量方法.

GB/T 30842-2014 fixes how well a high voltage test chamber must shield electromagnetically and how that shielding is to be measured.

Clause 1 states that the standard specifies the shielding effectiveness requirements and the measurement methods inside the chamber over the 10 kHz to 3 GHz frequency range, that the frequency can be extended to 10 GHz, and that it applies to the evaluation and measurement of the electromagnetic shielding effectiveness of high voltage laboratories.

Clause 3 takes its terms from GB/T 4365 and adds three: shielding effectiveness, as the measure of a shield's ability to isolate or limit electromagnetic waves, usually expressed as the ratio of the incident to the transmitted wave magnitude in decibels; the high voltage test chamber, as an electromagnetically shielded facility specially designed for testing high-voltage power equipment; and the testing area of that chamber, the region in which the device under test is placed and tested.

Clause 4 divides high voltage test chambers into four categories according to use, described in Annex C, sets the shielding effectiveness requirements in Table 1 and adds requirements on insulation resistance and grounding resistance.

Clause 5 carries the general requirements, covering the measurement environment, the measurement equipment and antennas, the measurement frequencies and the calculation of shielding effectiveness.

Clause 6 gives the measurement itself, with the requirements on the chamber being measured, the shielding effectiveness measurement method, the measurement of high voltage electric field shielding attenuation and the determination of the measurements.

Annex A, the only normative annex, holds the requirements and measurement methods for insulation resistance and grounding resistance, while the informative Annex B covers the high voltage electric field shielding attenuation measurement and Annex C the classification of the chambers.

The draft breaks off early in clause 4, so the shielding effectiveness values of Table 1 and the measurement procedures are not shown. It was issued on 24 June 2014 and has applied since 22 January 2015.

Found what you need?

Document preview — GB/T 30842-2014

National Standard of the People's Republic of China

ICS
33.100
Classification
L 06

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 high voltage test chamber shielding effectiveness in claim
  • 4.1 Category 1 high voltage test chamber
  • 4.2 high-pressure test chamber shielding effectiveness in claim
  • 4.3 high voltage test chamber insulation resistance, grounding resistance requirements
  • 5 General requirements
  • 5.1 Measurement Environmental Requirements
  • 5.2 Measurement equipment and antennas
  • 5.3 Measurement frequency
  • 5.4 Calculation of shielding effectiveness
  • 6.1 measured high voltage test chamber claim
  • 6.2 high-pressure test chamber shielding effectiveness measurement method
  • 6.3 high voltage electric field shielding attenuation measurement laboratory
  • 6.4 measurements determined
  • Annex B (informative) high-voltage electric field shielding attenuation measurement laboratory
  • Annex C (informative) on high voltage test chamber 19 Description Classification
  • References

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

1 Scope

This standard specifies the internal 10kHz ~ 3GHz frequency range of high voltage test chamber shielding effectiveness requirements and methods of measurement. Frequency can be expanded Exhibition to 10GHz.

This standard applies to the evaluation and measurement of high voltage laboratory electromagnetic shielding effectiveness.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 4365 Electrotechnical terminology Electromagnetic Compatibility

DL/T 475 grounding device parameter measurement guidelines

3 Terms and Definitions

GB/T 4365 defined by the following terms and definitions apply to this document.

3.1 Shielding effectiveness

To shield electromagnetic wave isolation or limit the ability of the measure. Usually expressed as a ratio of the magnitude of the incident and transmitted wave, expressed in decibels.

3.2 High voltage test chamber

High voltage test chamber is an electromagnetic shield with facilities specially designed for high-voltage power equipment testing.

3.3 High-voltage laboratory test area

High voltage test chamber for placing the device under test and the test region.

4 High voltage test chamber shielding effectiveness requirements

4.1 Classification high voltage test chamber

High voltage test chamber is divided into four categories according to use, classification described in Appendix C.

4.2 High-pressure test chamber shielding effectiveness requirements

High voltage test chamber shielding effectiveness requirements of Table 1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 30842-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 30842-2014

$295.00