GB/T 30192-2025Water evaporative cooling air handling units (English PDF)
水蒸发冷却空调机组
Open the GB/T 30192-2025 preview as PDF
This is a limited preview
Buy now to download the full PDF (20 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 31, 2025
Implementation date
May 1, 2026
Scope
GB/T 30192-2025 is the English-translated version of 水蒸发冷却空调机组.
GB/T 30192-2025 is the Chinese national standard covering cooling air by evaporating water rather than by a refrigeration cycle - the direct and indirect stages, the cooling capacity against the wet bulb rather than the dry bulb, the water consumption, and the hygiene of a wet surface in an air stream. In the dry northwest this replaces mechanical cooling almost entirely. Issued on 31 October 2025, it has been in force since 1 May 2026, replacing GB/T 30192-2013.
Document preview — GB/T 30192-2025
National Standard of the People's Republic of China
- ICS
- 91.140.30
- Classification
- P 48
- Replacing
- GB/T 30192-2013
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1.Scope1
- 2 Normative References1
- 3.Terms and Definitions1
- 4.Classification and Labeling3
- 5 General Requirements4
- 6 Requirements5
- 8.Inspection Rule11
- 14 Appendix B (Normative) Test Methods for Cooling Performance of Units16
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part
1.Structure and Drafting Rules of Standardization Documents". Drafting. This document replaces GB/T 30192-2013 "Water Evaporative Cooling Air Conditioning Units". Compared with GB/T 30192-2013, the only changes are structural adjustments. Aside from editorial changes, the main technical changes are as follows:
a) The scope of application has been changed (see Chapter 1, Chapter 1 of the.2013 edition);
b) The terms "evaporative cooling air conditioning unit", "direct evaporative cooler", "indirect evaporative cooler", "rated water consumption", and "customized water supply" have been changed. Definitions of cooling capacity, rated cooling water consumption ratio, and rated energy efficiency ratio (see 3.1~3.3, 3.8~3.10, 3.12, and 3.1~ in the.2013 edition). 3.3, 3.9, 3.14, 3.16, and 3.15);
c) The terms multi-stage evaporative cooler, standard air condition, rated air volume, external static pressure, rated power, and direct evaporative cooling have been removed. Efficiency, indirect evaporative cooling efficiency, isenthalpic cooling capacity, isohumid cooling capacity, and their definitions (see section
3.4 of the.2013 edition). 3.8, 3.10~3.13);
d) Added the terms output air, working air, supply air volume, external static pressure, and seasonal energy efficiency ratio (ESR) and their definitions (see 3.4~3.7, 3.13);
e) The classification and labeling have been changed (see Chapter 4, Chapter 4 of the.2013 edition);
f) General requirements have been changed (see Chapter 5,
5.1 of the.2013 edition);
g) Improved appearance, leak-proof performance, enclosure deformation rate, outlet air temperature, chilled water flow rate, chilled water pump head, and rated water consumption. The requirements for seasonal energy efficiency ratio (ESR) for cooling are specified in sections 6.1, 6.2.3, 6.2.5, 6.2.8, 6.2.10~6.2.12, and 6.2.15, and direct evaporation has been removed. Rated cooling capacity of the cooling section, rated cooling capacity of the indirect evaporative cooling section, and ventilation and drying requirements (see sections
5.2.5 of the.2013 edition). 5.2.12);
h) The test conditions have been changed (see 7.2.2,
6.2.2 in the.2013 version);
1 Scope
GB/T 30192-2025 is the Chinese national standard covering cooling air by evaporating water rather than by a refrigeration cycle - the direct and indirect stages, the cooling capacity against the wet bulb rather than the dry bulb, the water consumption, and the hygiene of a wet surface in an air stream. In the dry northwest this replaces mechanical cooling almost entirely. Issued on 31 October 2025, it has been in force since 1 May 2026, replacing GB/T 30192-2013.
This document specifies the classification and marking of water evaporative cooling air conditioning units (hereinafter referred to as "units"), general requirements, testing methods, and inspection procedures. Inspection rules and marking, packaging, transportation and storage. This document applies to air-cooled heat exchangers that primarily use direct or indirect water evaporation cooling heat exchangers, with other cold sources providing cooling capacity. The heat exchanger can be used as an auxiliary heat exchanger to provide cold air or simultaneously provide cold air and chilled water in an air conditioning unit.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.
GB/T 1236-2017 Performance Test of Standardized Air Ducts for Industrial Ventilation Fans
GB/T 1727 General methods for preparing paint films
GB/T 4208 Degrees of protection provided by enclosures (IP code)
GB/T 4706.1 Safety of household and similar electrical appliances - Part
3 Terms and Definitions
The terms and definitions defined in GB/T 16803 and the following terms and definitions apply to this document.
3.1 The driving force is the water vapor transfer potential energy possessed by the difference between the partial pressure of water vapor in the air and the corresponding saturated water vapor pressure (hereinafter). (abbreviated as "dry air energy") is an air conditioning unit that drives water in the evaporative cooler to evaporate and exchange heat, providing cold air or simultaneously providing cold air and chilled water.
3.2 An air-cooling heat exchanger that uses dry air energy to drive water evaporation to cool the air, and the produced cold air is in direct contact with the water.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1727General methods for preparation of coating films
- GB/T 4208Degrees of protection provided by enclosures (IP code)
- GB/T 9068-1988Determination of sound power levels of refrigeration and air-conditioning equipment - Sound pressure methods
- GB/T 14294-2008Central station air handling units
- GB/T 14295Air filters
- GB/T 16803Equipment of heating ,ventilating, air conditioning and air cleaning terminology
GB/T 1236-2017 · GB/T 4706.1 · GB/T 9237 · GB 50736 · JB/T 10359 · JB/T 11964 · JB/T 14643-2022
Editions of GB/T 30192
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 30192-2025 | Water evaporative cooling air handling unit | current edition | Current |
| GB/T 30192-2013 | Water evaporative cooling air handling unit | previous edition | In force |
This page sells the current edition, GB/T 30192-2025. Earlier editions are listed for reference only.
How to Buy GB/T 30192-2025
- 1Add to cart. Click the "Buy GB/T 30192-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14295-2019 — Air filters
GB/T 16803-2018 — Equipment of heating ,ventilating, air conditioning and air cleaning terminology
GB/T 1727-2021 — General methods for preparation of coating films
Secure payment via Stripe
Payments accepted
GB/T 30192-2025
$500.00