Valid

GB/T 29851-2013Test method for measuring Boron and Aulminium in silicon materials used for photovoltaic applications by secondary ion mass spectrometry (English PDF)

光伏电池用硅材料中B、Al受主杂质含量的二次离子质谱测量方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 29851-2013 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 12, 2013

Implementation date

April 15, 2014

Scope

GB/T 29851-2013 is the English-translated version of 光伏电池用硅材料中B、Al受主杂质含量的二次离子质谱测量方法.

GB/T 29851-2013 is the Chinese standard "Test method for measuring Boron and Aulminium in silicon materials used for photovoltaic applications by secondary ion mass spectrometry".

Its scope clause reads: This standard specifies the method for the determination of photovoltaic cells with secondary ion mass spectrometry (SIMS) with boron silicon and aluminum content.

This standard applies to solar cell silicon material quantitative impurity boron and aluminum content by analysis, in which boron and aluminum concentrations were greater than 1 × 1013atoms/cm3.

Other measuring acceptor impurity may also refer to this standard. Its clauses include principle of the method; disturbances; instruments and equipment.

Found what you need?

Document preview — GB/T 29851-2013

National Standard of the People's Republic of China

ICS
29.045
Classification
H 82

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 principle of the method
  • 3 disturbances
  • 4 instruments and equipment

1 Scope

This standard specifies the method for the determination of photovoltaic cells with secondary ion mass spectrometry (SIMS) with boron silicon and aluminum content.

This standard applies to solar cell silicon material quantitative impurity boron and aluminum content by analysis, in which boron and aluminum concentrations were greater than

1 × 1013atoms/cm3. Other measuring acceptor impurity may also refer to this standard.

2 principle of the method

Under high vacuum, the oxygen ions produced by a primary ion source, the accelerated, purified and focused, bombarding the sample surface, a variety of sputtered particle

Son, in which ions (ie, secondary ion) leads, by a different charge to mass ratio mass spectrometer to separate ions, record and calculate the sample of boron, aluminum sub

And other secondary ion intensity ratio of silicon (B)/(Si), (Al)/(Si), and the use of the relative sensitivity factors quantified.

3 disturbances

3.1

sample surface adsorption of boron and aluminum can interfere with the measurement sample of boron and aluminum.

3.2

from SIMS instrument sample chamber adsorbed onto the sample surface boron and aluminum can interfere with the measurement sample of boron and aluminum.

3.3

in the sample holder window range of the sample surface should be flat, in order to ensure that each sample is moved to the analysis position, its surface with an ion collector

The inclination of the optical system unchanged, otherwise the measurement accuracy and precision will be reduced.

3.4

Measuring accuracy and precision with the sample surface roughness increases significantly reduced, the surface of the sample by chemical mechanical polishing

Light be eliminated.

3.5

Standard samples of boron and aluminum uneven distribution will affect the measurement accuracy.

3.6

Standard deviation boron and aluminum sample nominal concentrations may cause measurement deviations.

3.7

due to different instruments or different instruments in the same state, the detection limit may be different.

3.8

Because the secondary ion mass spectrometry is a destructive test, it should be sampled and the samples taken shall be representative of the nature of the batch of silicon materials.

This standard does not establish uniform methods of sampling, as most appropriate sampling plan based on different samples circumstances are different. In order to achieve secondary

Conference purpose, the sampling plan should be tested before the test to get the two sides recognized.

4 instruments and equipment

4.1 magnetic sector SIMS

Instruments and equipment required oxygen primary ion source, the electron multiplier can detect positive secondary ions and Faraday cup detector, excellent mass resolution should

In 1500.

4.2 cryogenic liquid nitrogen or liquid helium cooling plates

If the vacuum analysis chamber is greater than 1.3 × 10-6Pa, application of liquid nitrogen or liquid helium cryogenic cooling plate surround analysis chamber sample holder.

If the vacuum analysis chamber is less than 1.3 × 10-6Pa, the cooling is not required.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 29851-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29851-2013

$105.00