Scope

GB/T 29161-2012 is the English-translated version of 中子活化型煤炭在线分析仪.

GB/T 29161-2012 is the Chinese standard "Specifications of on-line analyzer for coal based on neutron activation analysis".

Its scope clause reads: This standard specifies the neutron-activated coal-line analyzers composition, classification, technical requirements, test methods, inspection rules and signs, including Equipment, accompanying documents, transport and storage.

This standard applies to neutron-activated coal-line analyzer. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 29161-2012

National Standard of the People's Republic of China

ICS
73.040
Classification
D 21

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Prompt gamma-ray neutron activation analysis promptgammaneutronactivationanalysis (PGNAA)
  • 3.2 Pulsed fast neutron activation analysis pulsefastandthermalneutronactivationanalysis (PFTNA)
  • 3.3 Neutron activation type coal line analyzer

1 Scope

This standard specifies the neutron-activated coal-line analyzers composition, classification, technical requirements, test methods, inspection rules and signs, including

Equipment, accompanying documents, transport and storage.

This standard applies to neutron-activated coal-line analyzer.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 191 Packaging - Pictorial signs

GB 474 coal sample preparation

GB 4793.1-2007 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements

GB 5172 particle accelerator radiation protection

GB 5226.1-2002 Safety of machinery - Electrical machinery and electrical equipment - Part 1. General requirements

GB/T 6543 transportation corrugated packaging single and double corrugated boxes

GB 11806-2004 safe transport of radioactive materials regulations

GB/T 12464 ordinary wooden box

Radiation safety isotope instrumentation installed on the device GB 14052 requirements

GB 15479 Industrial Automation Instrumentation Isolation resistance strength technical requirements and test methods

GB 18871-2002 ionizing radiation protection and safety of radiation sources basic standards

GB part/T 19494.2 coal mechanization sampling 2. Preparation of coal sample

GB/T 19952-2005 online coal analyzers to measure performance evaluation method

3 Terms and Definitions

GB/T 19952-2005 define the following terms and definitions apply to this document.

3.1 Prompt gamma-ray neutron activation analysis promptgammaneutronactivationanalysis (PGNAA)

By thermal neutron bombardment of target nuclei of various elements in the sample, so that after the capture of thermal neutrons generated excited excited compound nucleus, in

< In the 10-14s time release characteristics deexcitation gamma rays. According to the position of characteristic gamma-ray peaks (energy) and intensity (peak area) elements into

Line qualitative and quantitative analysis, coal measure all major elements other than carbon, oxygen.

3.2 Pulsed fast neutron activation analysis pulsefastandthermalneutronactivationanalysis (PFTNA)

Pulsed fast neutron hit the target material, thermal neutron and target nucleus thermal neutron capture reaction by prompt gamma-ray and fast feature

Prompt feature neutron and target nucleus inelastic scattering reaction to the release of gamma-rays. According to the position of characteristic gamma-ray peaks (energy) and intensity (Peak area) on the qualitative and quantitative analysis of the elements, the main elements of all measurable coal include carbon, including oxygen.

3.3 Neutron activation type coal line analyzer

Using PGNAA and PFTNA technology, using neutron activation analysis principle, processing and transportation of coal in the process of a plurality of indicators […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 29161-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29161-2012

$255.00