Valid

GB/T 28541-2012Insulation co-ordination for equipments of ±800kV high voltage direct current converter stations (English PDF)

±800kV高压直流换流站设备的绝缘配合

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB/T 28541-2012 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 29, 2012

Implementation date

November 1, 2012

Scope

GB/T 28541-2012 is the English-translated version of ±800kV高压直流换流站设备的绝缘配合.

GB/T 28541-2012 is the Chinese standard "Insulation co-ordination for equipments of ±800kV high voltage direct current converter stations".

Its scope clause reads: This standard specifies the equipment insulation level selection principle gives withstand voltage representative, in the development of various equipment standards, should In accordance with the requirements of the standard, to determine equipment insulation level.

This standard applies to ± 800kV DC Converter Station commutation and DC field equipment insulation coordination. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 28541-2012

National Standard of the People's Republic of China

ICS
29.080.01
Classification
K 40

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Abbreviations
  • 5 conditions of use
  • 5.1 normal ambient conditions
  • 5.2 standard reference atmospheric conditions
  • 5.3 Temperature calibration
  • 5.4 Altitude correction
  • 6.1 Insulation coordination for equipment
  • 6.2 effect on the device voltage
  • 6.4 insulation performance test equipment
  • 7 ± 800kV DC Converter Station and overvoltage protection arrester
  • 7.1 ± 800kV HVDC converter station Overvoltage category
  • 7.2 ± 800kV HVDC converter station equipment lightning protection
  • 8.1 Overview
  • 8.2 determine the requirements for withstand voltage (Urw)
  • 8.3 determine the rated withstand voltage
  • 9 ± 800kV HVDC converter station equipment insulation level of
  • 9.2 HVDC converter station equipment insulation level of
  • Appendix A (Informative Appendix) ± 800kV HVDC converter station insulation with 16 examples

1 Scope

This standard specifies the equipment insulation level selection principle gives withstand voltage representative, in the development of various equipment standards, should

In accordance with the requirements of the standard, to determine equipment insulation level.

This standard applies to ± 800kV DC Converter Station commutation and DC field equipment insulation coordination.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB 311.1-1997 insulated high voltage transmission and distribution equipment

GB/T 311.2-2002 Insulation coordination - Part 2. insulated high voltage transmission and distribution equipment use guidelines

GB/T 311.3-2007 insulation coordination - Part 3. HVDC converter station insulation coordination procedures

GB 11032-2010 metal oxide surge arresters without gaps

GB/T 13498-2008 HVDC term

GB/T 22389-2008 HVDC converter station gapless metal oxide surge arresters Guide

IEC 60700-1.2008 HVDC thyristor valves - Part 1. Electrical testing

IEC 60721-2-2 Electrical Engineering Classification of environmental conditions - Part 2 2 precipitation and wind

3 Terms and Definitions

GB/T 311.3-2007, GB 11032-2010, GB/T 13498-2008 and GB/T 22389-2008 defined and the following

The terms and definitions apply to this document. For ease of use, repeat the following list of GB/T 311.3-2007, GB/T 22389-2008

Some terms and definitions.

3.1 DC system voltage

The highest average ground voltage or the average operating voltage, not including harmonics and commutation overshoot.

[GB/T 311.3-2007, Definition 3.1]

3.2 Continuous operating voltage maximum peak (PCOV)

Continuous operating voltage peak value on the DC side of the converter station equipment, including commutation overshoot.

[GB/T 311.3-2007, the definition 3.2]

3.3 Continuous operating voltage amplitude (CCOV)

Continuous operating voltage peak value on the DC side of the converter station equipment, but does not include commutation overshoot.

[GB/T 311.3-2007, the definition 3.3]

3.4 Overvoltage

Single-phase-to-ground or phase conductors - continuous transport system exceeds the maximum operating voltage AC peak or DC-DC converter station side between phase conductors […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Similar standards

How to Download GB/T 28541-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 28541-2012