GB/T 27730-2011Determination of dimethyl fumarate in toys - Gas chromatography-mass spectrometry method (English PDF)
玩具产品中富马酸二甲酯含量的测定 气相色谱-质谱联用(GC-MS)法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 27730-2011 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 30, 2011
Implementation date
July 1, 2012
Scope
GB/T 27730-2011 is the English-translated version of 玩具产品中富马酸二甲酯含量的测定 气相色谱-质谱联用(GC-MS)法.
GB/T 27730-2011 is the Chinese standard "Determination of dimethyl fumarate in toys - Gas chromatography-mass spectrometry method". Its scope clause reads: This standard specifies the toys in dimethyl fumarate content by gas chromatography - mass spectrometry detection methods.
This standard applies to toys, leather products, textiles, wood and other materials in the residue of dimethyl fumarate and dimethyl fumarate desiccant Ester content.
Other materials may refer to. Principle 2 Using ethyl acetate sample of dimethyl fumarate ultrasonic extraction, the extract was filtered and concentrated to volume by gas chromatography - mass spectrometry Spectrometer (GC-MS) was measured using selected ion qualitative and quantitative internal standard. Its clauses include reagents and materials; device.
Found what you need?
Document preview — GB/T 27730-2011
National Standard of the People's Republic of China
- ICS
- 97.200.50
- Classification
- Y 57
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 3 Reagents and materials
- 3.3 Internal standard
- 3.4 DMF standard stock solution
- 3.5 internal standard stock solution
- 3.6 internal standard working solution
- 3.7 standard working solution
- 3.8 neutral alumina SPE
- 4 Device
- 4.1 Gas chromatography - mass spectrometry (GC-MS)
1 Scope
This standard specifies the toys in dimethyl fumarate content by gas chromatography - mass spectrometry detection methods.
This standard applies to toys, leather products, textiles, wood and other materials in the residue of dimethyl fumarate and dimethyl fumarate desiccant
Ester content. Other materials may refer to.
Principle 2
Using ethyl acetate sample of dimethyl fumarate ultrasonic extraction, the extract was filtered and concentrated to volume by gas chromatography - mass spectrometry
Spectrometer (GC-MS) was measured using selected ion qualitative and quantitative internal standard.
3 Reagents and materials
3.1
ethyl acetate, analytical grade.
3.2
Standard substance dimethyl fumarate (dimethylfumarate, referred to as DMF) (CASNo..624-49-7). mass fraction of not less than
99.0%.
3.3 Internal standard
malonate (dimethylmalonate, abbreviated DMM) (CASNo..108-59-8), the mass fraction of not less than
99%; or diethyl malonate (diethylmalonate, abbreviated DEM) (CASNo..105-53-3), mass fraction of not less than 99%.
3.4 DMF standard stock solution
accurately weighed 0.1g (accurate to 0.0001g) in DMF standard (3.2), with ethyl acetate (3.1)
Constant volume to 100mL, formulated at a concentration of 1000mg/L of standard stock solution.
3.5 internal standard stock solution
accurately weighed 0.1g (accurate to 0.0001g) of DMM or DEM (3.3), with ethyl acetate (3.1) constant volume
To 100mL, formulated as standard stock solution at a concentration of 1000mg/L of.
Note 1. This standard selected two internal standard, can be used for quantitative detection in the actual testing, optionally one of the internal standard.
Note 2. The standard and internal standard stock solution should be in the 0 °C ~ 4 °C refrigerator, valid for three months.
3.6 internal standard working solution
the internal standard stock solution (3.5) dilute the concentration of the internal standard preparation work between 0.05mg/L ~ 10.00mg/L of
Solution.
3.7 standard working solution
DMF standard stock solution (3.4) diluted formulation at a concentration between 0.005mg/L ~ 5.00mg/L Rich
Horse dimethyl standard working solution, the solution of the working internal standard working solution (3.6) in the preparation process, and make it to be and the concentration of the internal standard
Test sample internal standard concentration close.
Note. The internal standard working solution and standard solution should be stored at 0 °C ~ 4 °C in the period of one month.
3.8 neutral alumina SPE
1000mg/6mL.
4 Device
4.1 Gas chromatography - mass spectrometry (GC-MS)
with EI source.
GB/T 27689-2025 | GB 28482-2012 | GB 28265-2012 | GB/T 32441-2026 | GB/T 24914-2026 | GB/T 22788-2026 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 27730-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 27730-2011
$135.00