Scope

GB/T 27639-2011 is the English-translated version of 结核病病原菌实时荧光PCR检测方法.

GB/T 27639-2011 is the Chinese standard "Real-time PCR method for the detection of Tuberculosis pathogenic organisms". Its scope clause reads: This standard specifies the technical to Mycobacterium tuberculosis complex, M. tuberculosis, M. bovis real-time PCR detection method Summing practices.

This standard applies to the rapid detection of bacterial cultures, blood, milk samples, sputum, tissue and organ, stool samples and other clinical Mycobacterium tuberculosis Composite group, M. tuberculosis, M. bovis. Its clauses include abbreviations.

Found what you need?

Document preview — GB/T 27639-2011

National Standard of the People's Republic of China

ICS
11.220
Classification
B 41

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Abbreviations

1 Scope

This standard specifies the technical to Mycobacterium tuberculosis complex, M. tuberculosis, M. bovis real-time PCR detection method

Summing practices.

This standard applies to the rapid detection of bacterial cultures, blood, milk samples, sputum, tissue and organ, stool samples and other clinical Mycobacterium tuberculosis

Composite group, M. tuberculosis, M. bovis.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

Laboratory use specifications and test methods GB/T 6682-2008 Analysis

GB 19489-2008 General requirements for laboratory biosafety

3 Abbreviations

The following abbreviations apply to this document.

Fluorescent signal cycle number reaches a set threshold when experienced. Ct value.

dNTP. deoxyribonucleosidetriphosphate, deoxynucleoside triphosphates.

DMSO. dimethylsulfoxide, dimethyl sulfoxide.

EDTA. ethylenediaminetetraaceticacid, ethylenediaminetetraacetic acid.

PBS. phosphatebuffersolution, phosphate buffer.

PCR. polymerasechainreaction, polymerase chain reaction.

Taq enzyme. TaqDNA polymerase.

UDG enzyme. uracilDNAglycosylase, uracil DNA glycosylase.

Principle 4

This method uses a standard probe TaqMan real-time PCR technology principle. The reaction system includes one pair for the amplification of DNA Primer, and a PCR product hybridized specifically with the fluorescently labeled probe. Probe 5 'end labeled with a fluorescent reporter group is called

Su, 3 'end labeled quencher. When performing PCR extension reaction, Taq polymerase 5 'exonuclease activity of the 5' fluorophore from the probe

Cutting down to the quencher group separate, so the instrument can detect the fluorescence signal 5 'fluorophore issued, part of PCR amplification

Generating part of the fluorescent signal generated increase was accompanied. With the accumulation of amplification cycles increase, the instrument detects the fluorescent signal

The reaction changes the amount of amplification product.

This standard provides specific detection of Mycobacterium tuberculosis complex, M. tuberculosis and M. bovis total of four sets of real-time PCR detection

The method (see Table 1). Wherein the Mycobacterium tuberculosis complex-specific real-time PCR method, respectively IS6110, IS1081 inserted gene

Sequence template design specific amplification primers and probes; M. tuberculosis, M. bovis-specific real-time PCR method, respectively bacteria

Species-specific genomic sequence as a template design specific amplification primers and probes.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 27639-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 27639-2011

$205.00