Scope
GB/T 27603-2011 is the English-translated version of 工业电雷管射频阻抗测定.
GB/T 27603-2011 is the Chinese standard "Measurement of radiofrequency impedance for industrial electric detonator". Its scope clause reads: This standard specifies the principles of industrial electric detonators RF impedance measurement, instruments, equipment and devices, test conditions, and test sample preparation program.
This standard applies to the determination of industrial electric detonators to 1MHz ~ 1300MHz frequency impedance.
Principle 2 RF impedance analyzer, through the extension of the cable, a short-circuit (0ohm), breaking (0S) and three standard 50ohm terminal 1MHz ~ 1300MHz frequency range automatic calibration, and then on the calibration frequencies of industrial electric detonator RF impedance measurements, according to public Formula (1) shows the direct RF impedance of the resistance component and reactance component values.
Measurement system block diagram shown in Figure 1. Z = R jX (1) Where.
Numerical Z --- RF impedance in ohms (ohm); Numerical R --- RF impedance of the resistance component in ohms (ohm); j --- -1; X --- RF impedance reactance component value in ohms (ohm). figure 1 3 apparatus, equipment and apparatus RF Impedance Analyzer. standard terminal should be equipped with extension cable and short-circuit (0ohm), breaking (0S) and 50ohm of three calibration; the instrument Operating frequency of 1MHz ~ 1300MHz, the measured current is not greater than 500µalpha, extending the length of the cable should be suitable for industrial electric detonator RF resistance Security measure antibody; the extension cable terminal should be adapted to connect with the industrial electric detonator. Its clauses include test conditions.
Found what you need?
Document preview — GB/T 27603-2011
National Standard of the People's Republic of China
- ICS
- 71.100.30
- Classification
- G 89
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
1 Scope
This standard specifies the principles of industrial electric detonators RF impedance measurement, instruments, equipment and devices, test conditions, and test sample preparation program.
This standard applies to the determination of industrial electric detonators to 1MHz ~ 1300MHz frequency impedance.
Principle 2
RF impedance analyzer, through the extension of the cable, a short-circuit (0ohm), breaking (0S) and three standard 50ohm terminal 1MHz ~
1300MHz frequency range automatic calibration, and then on the calibration frequencies of industrial electric detonator RF impedance measurements, according to public
Formula (1) shows the direct RF impedance of the resistance component and reactance component values. Measurement system block diagram shown in Figure 1.
Z = R jX (1)
Where.
Numerical Z --- RF impedance in ohms (ohm);
Numerical R --- RF impedance of the resistance component in ohms (ohm);
j --- -1;
X --- RF impedance reactance component value in ohms (ohm).
figure 1
3 apparatus, equipment and apparatus
RF Impedance Analyzer. standard terminal should be equipped with extension cable and short-circuit (0ohm), breaking (0S) and 50ohm of three calibration; the instrument
Operating frequency of 1MHz ~ 1300MHz, the measured current is not greater than 500µalpha, extending the length of the cable should be suitable for industrial electric detonator RF resistance
Security measure antibody; the extension cable terminal should be adapted to connect with the industrial electric detonator.
4 Test conditions
4.1 Environmental conditions
Determination of industrial electric detonators RF impedance of the ambient temperature should be 16 °C ~ 32 °C, relative humidity should not exceed 75%. During the measurements,
Record the actual environmental conditions.
GB/T 34710.2-2018 | GB/T 34544-2017 | GB/T 27602-2011 | GB 24284-2026 | GB/T 27601-2011 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 27603-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 27603-2011
$85.00