GB/T 27601-2011Test method of resisting stray current for industrial electric detonator (English PDF)
工业电雷管抗杂散电流试验方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 27601-2011 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 5, 2011
Implementation date
May 1, 2012
Scope
GB/T 27601-2011 is the English-translated version of 工业电雷管抗杂散电流试验方法.
GB/T 27601-2011 is the Chinese standard "Test method of resisting stray current for industrial electric detonator". Its scope clause reads: This standard specifies the principles of industrial electric detonators anti-stray current test, apparatus, equipment and installations, environmental conditions and test procedures for test.
This standard applies to the resistance value is not more than the glow wire bridge industrial electric detonators 10ohm anti-stray current test.
Principle 2 The impact of industrial electric detonators may be low frequency stray current interference equivalent to a predetermined duration and magnitude of the direct current pulses The impact of industrial electric detonator bridge.
Test principle is shown in Figure 1. Explanation. 1 --- stray current tester; 2 --- multiplexer blow-out preventer; 3 --- industrial electric detonator; R --- analog resistor; S --- switch. figure 1 3 apparatus, equipment and apparatus.
Found what you need?
Document preview — GB/T 27601-2011
National Standard of the People's Republic of China
- ICS
- 71.100.30
- Classification
- G 89
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
1 Scope
This standard specifies the principles of industrial electric detonators anti-stray current test, apparatus, equipment and installations, environmental conditions and test procedures for test.
This standard applies to the resistance value is not more than the glow wire bridge industrial electric detonators 10ohm anti-stray current test.
Principle 2
The impact of industrial electric detonators may be low frequency stray current interference equivalent to a predetermined duration and magnitude of the direct current pulses
The impact of industrial electric detonator bridge. Test principle is shown in Figure 1.
Explanation.
1 --- stray current tester;
2 --- multiplexer blow-out preventer;
3 --- industrial electric detonator;
R --- analog resistor;
S --- switch.
figure 1
3 apparatus, equipment and apparatus
3.1 Stray Current Tester
Stray current tester shall meet the following requirements.
--- Output pulse amplitude. 100mA ± 5mA;
--- Output pulse width. 300ms ± 5ms;
--- Pulse duration. 500ms ± 10ms;
--- Pulse rise time. less than 2ms;
--- Number of pulses. not less than 2000;
--- Maximum load capacity. 10ohm.
3.2 Resistance measurer
Resistance measuring instrument shall meet the following requirements.
--- Range. 0.1ohm ~ 20ohm;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 27601-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 27601-2011
$95.00