Valid

GB/T 25918-2010Portable calibration instrument for water meters (English PDF)

便携式水表校验仪

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 25918-2010 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

January 14, 2011

Implementation date

May 1, 2011

Scope

GB/T 25918-2010 is the English-translated version of 便携式水表校验仪.

GB/T 25918-2010 is the Chinese standard "Portable calibration instrument for water meters".

Its scope clause reads: This standard specifies the terminology and definition of portable water meter calibrator (hereinafter referred to as water meter calibrator), general requirements, measurement requirements, technology Requirements, test methods, test rules and signs, packaging, transportation and storage.

This standard applies to portable water meter calibrators with a maximum flow rate of less than 16 m3/h using standard table method. Its clauses include normative reference documents; terms and definitions.

Found what you need?

Document preview — GB/T 25918-2010

National Standard of the People's Republic of China

ICS
17.120.10
Classification
N 12

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions

1 Scope

This standard specifies the terminology and definition of portable water meter calibrator (hereinafter referred to as water meter calibrator), general requirements, measurement requirements, technology

Requirements, test methods, test rules and signs, packaging, transportation and storage.

This standard applies to portable water meter calibrators with a maximum flow rate of less than 16 m3/h using standard table method.

2 normative reference documents

The terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard

Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard.

GB/T 191 Packaging and Storage Icons (GB/T 191-2008, ISO 780..1997, MOD)

GB/T 321-2005 Number of priority and priority (ISO 3. 1973, IDT)

GB/T 778.1-2007 Measurement of water flow in closed pipelines Drinking cold water meters and hot water meters - Part 1. Specifications (ISO 4064-1..2005, IDT)

GB/T 778.3-2007 Measurement of water flow in closed pipelines Drinking cold water meters and hot water meters Part 3. Test methods

Law and test equipment (ISO 4064-3..2005, IDT)

GB/T 2423.2 Environmental testing for electric and electronic products - Part 2. Test methods - Test B. High temperature (GB/T 2423.2-

2001, IEC 60068-2-2. 1974, IDT)

GB/T 2423.4 Environmental testing for electric and electronic products - Part 2. Test methods - Test Db alternating hot and humid (12h 12h

Cycle) (GB/T 2423.4-2008, IEC 60068-2-30..2005, IDT)

GB/T 2423.7 Environmental testing for electric and electronic products - Part 2. Test methods - Tests Ec and guidance. Dumping and overturning (main

For equipment type samples) (GB/T 2423.7-1995, idtIEC 60068-2-31. 1982)

GB 4208-2008 enclosure protection class (IP code) (IEC 60529..2001, IDT)

General technical requirements for packaging of electromechanical products GB/T 13384-2008

GB/T 15479-1995 Industrial automation instrumentation Insulation resistance, dielectric strength Technical requirements and test methods

GB/T 17626.2 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test (GB/T 17626.2-2006,

IEC 61000-4-2..2001, IDT)

GB/T 17626.3 Electromagnetic compatibility test and measurement technology Radio frequency electromagnetic radiation immunity test (GB/T 17626.3-

2006, IEC 61000-4-3..2002, IDT)

GB/T 17626.4 Electromagnetic compatibility test and measurement techniques Electrical fast transient burst immunity test (GB/T 17626.4-

2008, IEC 61000-4-4..2004, IDT)

OIMLD11..2004 General requirements for electronic measuring instruments

3 terms and definitions

GB/T 778.1-2007 and the following terms and definitions apply to this standard.

3.1

A measurement error for checking the on-line water meter, easy to carry the water meter calibration equipment.

GB/T 778.1-2018 | GB/T 778.4-2018 | GB/T 21117-2007 | GB/T 28857-2025 | GB/T 25922-2023 | GB/T 25920-2010 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 25918-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 25918-2010

$225.00