Valid

GB/T 24800.7-2009Determination of brucine and strychnine in cosmetics by high performance liquid chromatography method (English PDF)

化妆品中马钱子碱和士的宁的测定 高效液相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 24800.7-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 30, 2009

Implementation date

May 1, 2010

Scope

GB/T 24800.7-2009 is the English-translated version of 化妆品中马钱子碱和士的宁的测定 高效液相色谱法.

GB/T 24800.7-2009 is the Chinese standard "Determination of brucine and strychnine in cosmetics by high performance liquid chromatography method". Its scope clause reads: This standard specifies a high performance liquid chromatographic method Ning cosmetics brucine and strychnine.

This standard applies to the determination of cosmetics rather brucine and strychnine. The standard detection and quantitation limits. brucine and strychnine detection limit of 2.5mg/kg, the limit of quantification for the 8mg/kg. Its clauses include reagents and materials.

Found what you need?

Document preview — GB/T 24800.7-2009

National Standard of the People's Republic of China

ICS
71.100.70
Classification
Y 42

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 4 Reagents and materials
  • 4.1 Methanol
  • 4.2 tetrahydrofuran
  • 4.4 methanol aqueous solution
  • 4.5 brucine and strychnine standards
  • 4.7 mixed standard stock solution of brucine and strychnine
  • 5.1 High Performance Liquid Chromatography (HPLC) instrument
  • 5.3 Analysis of balance
  • 5.4 centrifuge
  • 5.6 plug cuvette
  • 5.7 plug plastic centrifuge tube

1 Scope

This standard specifies a high performance liquid chromatographic method Ning cosmetics brucine and strychnine.

This standard applies to the determination of cosmetics rather brucine and strychnine.

The standard detection and quantitation limits. brucine and strychnine detection limit of 2.5mg/kg, the limit of quantification for the 8mg/kg.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD)

Principle 3

Sample by solvent extraction and centrifugal filtration, HPLC, external standard, liquid chromatography - mass spectrometry confirmed.

4 Reagents and materials

Unless otherwise indicated, the reagents used were of analytical grade water as a water GB/T 6682 regulations.

4.1 Methanol

chromatographically pure.

4.2 tetrahydrofuran

chromatography.

4.3

ammonium formate solution (0.01mol/L). Weigh accurately 0.6306g ammonium formate in 1L flask, add water to dissolve about 980mL,

PH was adjusted to 3.0 with formic acid, the volume to 1L spare.

4.4 methanol aqueous solution

accurate amount of 64mL of methanol and 36mL water, mix and reserve.

4.5 brucine and strychnine standards

purity of not less than 97%.

Stock standard solution 4.6 brucine and strychnine. Weigh accurately brucine and strychnine standard material each 100mg, were placed

100mL brown volumetric flask, and dissolved in methanol to volume, shake, formulated to concentrations of 1000µg/mL standard stock

Liquid stored in the dark at 4 °C, can be used for three months.

4.7 mixed standard stock solution of brucine and strychnine

accurate Pipette stock standard solution of brucine and strychnine were each 25mL

In 50mL brown volumetric flask with methanol to volume, the concentration of the solution rather brucine and strychnine were 500µg/mL.

5. Apparatus

5.1 High Performance Liquid Chromatography (HPLC) instrument

with a UV detector or diode array detector.

5.2

High performance liquid chromatography - mass spectrometry (LC-MS/MS) instrument. with electrospray ionization (ESI).

5.3 Analysis of balance

a sense of the amount of 0.0001g and 0.001g.

5.4 centrifuge

speed of not less than 5000r/min.

5.5

ultrasonic bath.

5.6 plug cuvette

10mL.

5.7 plug plastic centrifuge tube

10mL.

GB/T 29680-2013 | GB/T 29679-2013 | GB/T 29665-2013 | GB/T 24800.12-2009 | GB/T 24800.1-2009 | GB/T 24800.11-2009 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 24800.7-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 24800.7-2009

$165.00