GB/T 24800.5-2009Determination of nitrofurantoin and furazolidone in cosmetics by high performance liquid chromatography method (English PDF)
化妆品中呋喃妥因和呋喃唑酮的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 24800.5-2009 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 30, 2009
Implementation date
May 1, 2010
Scope
GB/T 24800.5-2009 is the English-translated version of 化妆品中呋喃妥因和呋喃唑酮的测定 高效液相色谱法.
GB/T 24800.5-2009 is the Chinese standard "Determination of nitrofurantoin and furazolidone in cosmetics by high performance liquid chromatography method". Its scope clause reads: This standard specifies the nitrofurantoin and HPLC method furazolidone in cosmetics.
This standard applies to cosmetics nitrofurantoin and furazolidone determination. The standard for nitrofurantoin and furazolidone detection limit of 2mg/kg, the limit of quantification for the 8mg/kg.
Principle 2 Acetonitrile - methanol (1 + 1, v/v) mixed solution of the solvent extraction, ultrasonic extraction, centrifugation, dried organic 0.45µm membrane filter, the solution Injected with a diode array detector liquid chromatography detection, external standard. Its clauses include reagents and materials; instrument.
Found what you need?
Document preview — GB/T 24800.5-2009
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 3 Reagents and materials
- 3.1 acetonitrile
- 3.2 Methanol
- 3.3 nitrofurantoin
- 3.4 furazolidone
- 3.6 Extraction solvent
- 3.8 mobile phase
- 3.9 standard stock solution (200µg/mL)
- 3.10 standard solution
- 4 Instrument
1 Scope
This standard specifies the nitrofurantoin and HPLC method furazolidone in cosmetics.
This standard applies to cosmetics nitrofurantoin and furazolidone determination.
The standard for nitrofurantoin and furazolidone detection limit of 2mg/kg, the limit of quantification for the 8mg/kg.
Principle 2
Acetonitrile - methanol (1 + 1, v/v) mixed solution of the solvent extraction, ultrasonic extraction, centrifugation, dried organic 0.45µm membrane filter, the solution
Injected with a diode array detector liquid chromatography detection, external standard.
3 Reagents and materials
Unless otherwise specified, reagents were of analytical grade.
3.1 acetonitrile
chromatography.
3.2 Methanol
chromatographically pure.
3.3 nitrofurantoin
purity of not less than 99%.
3.4 furazolidone
purity of not less than 99%.
3.5
acetic acid.
3.6 Extraction solvent
acetonitrile (3.1). methanol (3.2) the volume ratio of (1 + 1, v/v).
3.8 mobile phase
acetonitrile (3.1). 0.4% acetic acid solution (3.7) by weight (30 + 70, v/v).
3.9 standard stock solution (200µg/mL)
Weigh accurately respectively nitrofurantoin (3.3) and furazolidone (3.4) 0.02g, accurate to 0.0001g,
In 50mL beaker, add appropriate amount of acetonitrile was dissolved moved 100mL brown volumetric flask with acetonitrile to volume, at 4 °C dark, sealed, insurable
Save more than three months.
3.10 standard solution
take a certain amount of stock solution (3.9), phase (3.8) diluted to brown volumetric flask with mobile, preparation of a concentration
0.2µg/mL, 0.5µg/mL, 1.0µg/mL, 5µg/mL, 10µg/mL, a solution of 20µg/mL of.
3.11
pore size of 0.45µm organic filtration membrane.
Note. Due to nitrofurantoin and furazolidone highly sensitive to light, see light easily decomposed metamorphic, and thus preparation of standard solution must use brown volumetric flask, other
Also in need of treatment dark glassware, all the operations should be carried out in the absence of light. Operation should avoid inhalation and exposure to toxic standards
Reagents.
4 Instrument
4.1
liquid chromatograph equipped with a diode array detector.
4.2
micro-injector, 10µL.
4.3
ultrasonic cleaner.
4.4
Centrifuge, speed not less than 5000r/min.
4.5
solvent filter pore size can be placed in the organic filtration membrane 0.45µm.
4.6
plug cuvette 25mL.
GB/T 29680-2013 | GB/T 29679-2013 | GB/T 29665-2013 | GB/T 24800.12-2009 | GB/T 24800.1-2009 | GB/T 24800.11-2009 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 24800.5-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 24800.6-2009 — Determination of 21 sulfonamides in cosmetics by high performance liquid chromatography method
GB/T 24800.4-2009 — Determination of chlortalidone and phenothiazine in cosmetics by high performance liquid chromatography method
GB/T 24800.7-2009 — Determination of brucine and strychnine in cosmetics by high performance liquid chromatography method
GB/T 24800.5-2009