GB/T 23601-2009Method of eddy current testing for titanium and titanium alloy bars and wires (English PDF)
钛及钛合金棒、丝材涡流探伤方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 23601-2009 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
April 15, 2009
Implementation date
February 1, 2010
Scope
GB/T 23601-2009 is the English-translated version of 钛及钛合金棒、丝材涡流探伤方法.
GB/T 23601-2009 is the Chinese standard "Method of eddy current testing for titanium and titanium alloy bars and wires". Its scope clause reads: This standard specifies the titanium and titanium alloy bar, wire eddy current inspection requirements and acceptance regulations.
This standard applies to a diameter of 2mm ~ 16mm of titanium and titanium alloy rod, wire and surface eddy current testing near-surface defects. Its clauses include general requirements; testing system.
Found what you need?
Document preview — GB/T 23601-2009
National Standard of the People's Republic of China
- ICS
- 77.120.50
- Classification
- H 64
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 General requirements
- 2.1 Objective
- 2.2 staff
- 2.3 size and appearance quality
- 3 Testing System
- 3.1 eddy current flaw detector
- 3.2 detection coil
- 3.3 gearing
- 3.4 sorter
1 Scope
This standard specifies the titanium and titanium alloy bar, wire eddy current inspection requirements and acceptance regulations.
This standard applies to a diameter of 2mm ~ 16mm of titanium and titanium alloy rod, wire and surface eddy current testing near-surface defects.
2 General requirements
2.1 Objective
This method is mainly used to detect titanium and titanium alloy bar, wire products of surface and near surface defects, such as dents, cracks, and other exposure or
Exposed to the tissue surface discontinuities on.
2.2 staff
Operators should reach the ministerial or equivalent level and above grade I learn NDT personnel level, the issue of inspection reports and explain people
Members should meet ministerial or equivalent level learn grade II level and staff.
2.3 size and appearance quality
2.3.1
wire rod surface should be clean, can not affect the presence of test dirt, grease, metal shavings and other foreign substances.
Curvature 2.3.2 wire rods, the surface roughness and size tolerances shall comply with relevant product standards.
3 Testing System
3.1 eddy current flaw detector
3.1.1
eddy current flaw detector operating frequency range is generally 10kHz ~ 100kHz.
3.1.2
The instrument should include incentives, receives, amplifies and phase adjustment, filtering unit, and an alarm, display or recording device.
3.2 detection coil
3.2.1
and eddy current flaw detection coil combination can generate the induced current in the rods, wire surface or near-surface, and can detect rods, electrical wire
Changes in magnetic properties.
3.2.2
In ensuring rods, wire passed the detection coil does not scratch the rod, wire surface of the premise, as far as possible the use of encircling coil detector
Choose a high fill factor of the detection coil, usually not less than 0.7.
3.3 gearing
3.3.1
make wire rods evenly and smoothly through the coil, without causing damage to the surface of the wire rod.
3.3.2
have to ensure that the detection coils or scanning center of the track with the test rods, wire center line of the adjustment mechanism.
3.3.3 rods, wire feed speed of 5m/min ~ 80m/min
Change the selected speed should not exceed ± 10%.
3.4 sorter
We can distinguish between the Qualified or unqualified rods, wire, and its sorting.
Comparative Sample 4 4.1 Comparative Sample having artificial groove for adjusting the sensitivity performance testing, calibration and testing equipment as product acceptance criteria
The rod-like.
4.2
should be used in comparative sample was seized rods, wire material, geometry, uniform surface state and heat treatment process, and does not affect manual
Stick standard defect identification signal, wire preparation.
4.3
Comparative Sample optional V-shaped or U-shaped, rectangular groove. The comparative sample shall be at least three weeks to 120 ° spacing of the same size
Person-notch defects and artificial defects longitudinal groove uniform intervals of not less than 100mm.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 23601-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 23601-2009
$105.00