GB/T 21319-2007Method for the determination of avermectins residues in food of animal origin food - Enzyme linked immunosorbent assay (English PDF)
动物源食品中阿维菌素类药物残留的测定 酶联免疫吸附法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 21319-2007 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 29, 2007
Implementation date
April 1, 2008
Scope
GB/T 21319-2007 is the English-translated version of 动物源食品中阿维菌素类药物残留的测定 酶联免疫吸附法.
GB/T 21319-2007 is the Chinese standard "Method for the determination of avermectins residues in food of animal origin food - Enzyme linked immunosorbent assay".
Its scope clause reads: This standard specifies the food of animal origin avermectin residues in the enzyme-linked immunosorbent assay. This standard applies to the determination of avermectin, ivermectin and Eprinomectin residues in beef and beef liver.
The standard method detection limit. avermectin in beef and bovine liver tissue tissue detection limits were 2µg/kg. Its clauses include reagents and materials.
Found what you need?
Document preview — GB/T 21319-2007
National Standard of the People's Republic of China
- ICS
- 67.120
- Classification
- X 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 4 Reagents and materials
- 4.1 avermectin kit
- 4.4 Water
- 4.5 Buffer working solution
- 4.6 washing liquid working solution
1 Scope
This standard specifies the food of animal origin avermectin residues in the enzyme-linked immunosorbent assay.
This standard applies to the determination of avermectin, ivermectin and Eprinomectin residues in beef and beef liver.
The standard method detection limit. avermectin in beef and bovine liver tissue tissue detection limits were 2µg/kg.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-1992, neq ISO 3696. 1987)
Principle 3
By indirect competitive ELISA method, on the strips coated with coupling antigen, the sample remaining avermectin and microtiter plates
The antibody conjugate antigens competition avermectin after adding enzyme-labeled antibody reagent color, stop solution to stop the reaction. In using a microplate reader
Absorbance was measured at 450nm, and the absorbance of avermectin residues in negative correlation with the standard curve can be derived avermectin
Residues content of the drug.
4 Reagents and materials
4.1 avermectin kit
4.1.1
96 (12 × 8 wells) coated with antigen coupled avermectin.
4.1.2
avermectin standard solution (at least five times higher than the level of dilution, plus a blank).
4.1.3
avermectin antibody solution.
4.1.4
peroxidase label.
4.1.5 chromogenic substrate solution A solution
carbamide peroxide.
4.1.6 chromogenic substrate solution B solution
tetramethylbenzidine.
4.1.7 stop solution
1mol/L sulfuric acid.
4.1.8
buffer (2-fold concentrated solution).
4.1.9
washing liquid (20 times concentrate).
4.2
acetonitrile, n-hexane, dried over anhydrous sodium sulfate (AR).
4.3
basic alumina column Sep-PakVac12cc (2g).
4.4 Water
GB/T 6682 provided a water.
4.5 Buffer working solution
water to 2-fold concentrated buffer, press the volume ratio 1.1 dilution (1 + 1 part 2 fold concentrated buffer
Water) for dissolving the dry residue, the buffer can be stored for a month at the working fluid 4 °C.
4.6 washing liquid working solution
the water washings were concentrated 20 times by volume ratio of 1.19 dilution (1 part 20x concentrated washing liquid +19
Parts of water), washed ELISA plate wash solution can be saved for one month at 4 °C.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 21319-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 21319-2007
$105.00