GB/T 20975.4-2020Methods for chemical analysis of aluminium and aluminium alloys—Part 4:Determination of iron content (English PDF)

铝及铝合金化学分析方法 第4部分:铁含量的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 20975.4-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 2, 2020

Implementation date

May 1, 2021

Scope

GB/T 20975.4-2020 is the English-translated version of 铝及铝合金化学分析方法 第4部分:铁含量的测定.

GB/T 20975.4-2020 is the part of the Chinese series on the chemical analysis of aluminium and aluminium alloys that determines the iron content. It gives two methods, phenanthroline spectrophotometry for 0.0010 % to 3.50 % iron and potassium dichromate titration for more than 3.50 % to 65.00 %.

It applies to the arbitration determination of iron in aluminium and aluminium alloys. Aluminium producers and analytical laboratories use it. Issued on 2 June 2020, it has applied since 1 May 2021, replacing GB/T 20975.4-2008.

Found what you need?

Document preview — GB/T 20975.4-2020

National Standard of the People's Republic of China

ICS
77.120.10
Classification
H 12
Replacing
GB/T 20975.4-2008

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Phenanthroline spectrophotometry
  • 5 Potassium dichromate titration method
  • 6 Test report

Foreword

GB/T 20975 "Methods for Chemical Analysis of Aluminum and Aluminum Alloys" is divided into 37 parts.

---Part 1: Determination of mercury content;

---Part 2: Determination of arsenic content;

---Part 3: Determination of copper content;

---Part 4: Determination of iron content;

---Part 5: Determination of silicon content;

---Part 6: Determination of cadmium content;

---Part 7: Determination of manganese content;

---Part 8: Determination of zinc content;

---Part 9: Determination of lithium content by flame atomic absorption spectrometry;

---Part 10: Determination of tin content;

---Part 11: Determination of lead content;

---Part 12: Determination of titanium content;

---Part 13: Determination of vanadium content;

---Part 14: Determination of nickel content;

---Part 15: Determination of boron content;

---Part 16: Determination of magnesium content;

---Part 17: Determination of strontium content;

---Part 18: Determination of chromium content;

---Part 19: Determination of Zirconium Content;

---Part 20: Determination of Gallium Content Butyl Rhodamine B Spectrophotometry;

---Part 21: Determination of calcium content;

---Part 22: Determination of beryllium content;

---Part 23: Determination of antimony content;

---Part 24: Determination of total rare earth content;

---Part 25: Determination of element content by inductively coupled plasma atomic emission spectrometry;

---Part 26: Determination of carbon content by infrared absorption method;

---Part 27: Determination of cerium, lanthanum and scandium content by inductively coupled plasma atomic emission spectrometry;

---Part 28: Determination of cobalt content by flame atomic absorption spectrometry;

---Part 29: Determination of molybdenum content thiocyanate spectrophotometric method;

---Part 30: Determination of hydrogen content by heating extraction thermal conductivity method;

---Part 31: Determination of phosphorus content molybdenum blue spectrophotometric method;

---Part 32: Determination of Bismuth Content;

---Part 33: Determination of potassium content by flame atomic absorption spectrometry;

---Part 34: Determination of sodium content by flame atomic absorption spectrometry;

---Part 35: Determination of Tungsten Content Thiocyanate Spectrophotometric Method;

---Part 36: Determination of silver content by flame atomic absorption spectrometry;

--- Part 37: Determination of Niobium Content.

This part is Part 4 of GB/T 20975.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

This part replaces GB/T 20975.4-2008 "Methods for Chemical Analysis of Aluminum and Aluminum Alloys Part 4: Determination of Iron Content) Philippine Spectrophotometry. Compared with GB/T 20975.4-2008, the main technical changes in this part are as follows except for editorial changes.

--- Added standard use safety warnings;

--- Modify the "range" and increase the measurement range >3.50%~65.00% (see Chapter 1, Chapter 1 of the 2008 edition);

--- Added "Normative Reference Documents" (see Chapter 2);

--- Added "Terms and Definitions" (see Chapter 3);

---Modified the operation of different iron content in "Phenanthroline Spectrophotometry" and Table 1 (see 4.5.4.2, 2008 edition of 6.4.2);

---Modified the working curve of "Phenanthroline Spectrophotometry" (see 4.5.5.1, 6.5.1 in 2008 edition);

---Modified the precision of "Phenanthroline Spectrophotometry" (see Chapter 4.7, Chapter 8 of the 2008 edition);

--- Added the "potassium dichromate titration method" (see Chapter 5);

--- Deleted "Quality Assurance and Control" (see Chapter 9 of the 2008 edition);

--- Added "Test Report" (see Chapter 6).

1 Scope

This part of GB/T 20975 specifies the phenanthroline spectrophotometric method and potassium dichromate titration method for the determination of iron in aluminum and aluminum alloys. content.

This section applies to the arbitration determination of iron content in aluminum and aluminum alloys. Phenanthroline spectrophotometric determination range. 0.0010%~ 3.50%; determination range of potassium dichromate titration method. >3.50%~65.00%.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.

GB/T 8005.2 Terminology of Aluminum and Aluminum Alloy Part 2: Chemical Analysis

GB/T 8170-2008 Numerical rounding rules and the expression and determination of limit values

3 Terms and definitions

The terms and definitions defined in GB/T 8005.2 apply to this document.

4 Phenanthroline spectrophotometry

4.1 Method summary

The sample is dissolved in hydrochloric acid and hydrogen peroxide, and the iron is reduced with hydroxylamine hydrochloride. The pH of the test solution is controlled to be 3.5-4.5, so that the divalent iron ions and the adjacent Phenanthroline forms a stable orange-red complex, and its absorbance is measured at a wavelength of 510.0nm with a spectrophotometer to determine the iron content.

4.2 Reagents

Unless otherwise stated, only reagents and laboratory secondary water confirmed to be analytically pure are used in the analysis.

4.2.1 Hydrogen peroxide (rho=1.10g/mL).

4.2.2 Hydrochloric acid (5 1).

4.2.3 Hydrochloric acid (1 1).

4.2.4 Sodium hydroxide solution (200g/L), stored in plastic bottles.

4.2.5 Hydroxylamine hydrochloride solution (10g/L).

4.2.6 Phenanthroline solution (2.5g/L). Weigh 2.5g of phenanthroline (C12H8N2·H2O) or 3g of phenanthroline hydrochloride (C12H8N2·HCl·H2O) dissolved in warm water and cooled. Dilute to 1000mL with water and mix well.

4.2.7 Nickel chloride (NiCl2·6H2O) solution (1g/L).

4.2.8 Buffer solution. Weigh 272g of sodium acetate (CH3COONa·3H2O) and dissolve it with 500mL of water. After filtering, add 240mL of ice. Acetic acid (rho=1.05g/mL), dilute to 1000mL with water, and mix well.

4.2.9 Mixed solution. Combine hydroxylamine hydrochloride solution (4.2.5), o-phenanthroline solution (4.2.6) and buffer solution (4.2.8) to (1 1 3) The product is mixed with each other and stored in a brown bottle. The storage period does not exceed four weeks.

4.2.10 Iron standard storage solution. Use a certified standard solution for preparation first. Or weigh 0.2860g of Ozone which has been burnt at 600°C in advance Ferric fluoride [w(Fe2O3)>=99.99%], put in a.200mL beaker, add 30mL hydrochloric acid (4.2.3), heat to completely dissolve, cool, Transfer to a 1000mL volumetric flask, dilute to the mark with water, and mix. 1mL of this solution contains 0.2mg iron.

4.2.11 Iron standard solution A. Pipette 25.00mL iron standard stock solution (4.2.10) into a 100mL volumetric flask and dilute to the mark with water. Mix well (prepared when used). 1mL of this solution contains 0.05mg iron.

4.2.12 Iron standard solution B. Pipette 25.00mL iron standard stock solution (4.2.10) into a 500mL volumetric flask and dilute to the mark with water. Mix well (prepared when used). This solution 1mL contains 0.01mg iron.

4.3 Apparatus

Spectrophotometer.

4.4 Sample

Process the sample into chips not larger than 1mm.

4.5 Analysis steps

4.5.1 Sample

According to Table 1, weigh the sample (4.4) of the corresponding mass (m0) to the nearest 0.0001g.

4.5.2 Parallel experiment

Do two tests in parallel and take the average value.

4.5.3 Blank test

Do a blank test with the sample (4.5.1).

4.5.4 Determination

4.5.4.1 Place the test material (4.5.1) in a 250mL beaker, cover with a watch glass, add 25mL of hydrochloric acid (4.2.3) in batches, and wait vigorously. After the reaction, add 7 to 8 drops of hydrogen peroxide (4.2.1), if it is a pure aluminum sample, add a nickel chloride solution (4.2.7), and slowly heat until the sample is complete Dissolve completely, boil for 5 minutes, and cool. Aluminum alloys that are not easily dissolved by hydrochloric acid or have high silicon content can be dissolved in alkali. Place the sample (4.5.1) in In a 100mL silver beaker (or polytetrafluoroethylene beaker), carefully add 20mL of sodium hydroxide solution (4.2.4), and cover with a silver watch (or polytetrafluoroethylene cover), heat until the sample is completely dissolved, if the mass fraction of silicon in the sample is >=4.00%, keep the test solution at a temperature slightly lower than the boiling point 20min, carefully add the amount of water lost due to evaporation, boil for 2min~3min, wash the cup wall and watch dish with water, and dilute the test solution to about 25mL, add 20mL hydrochloric acid (4.2.2), boil slightly until the solution is clear, and cool.

4.5.4.2 When the iron mass fraction is 0.0010%~0.050%, transfer the sample solution (4.5.4.1) into a 100mL volumetric flask, if not The soluble matter is filtered with medium-speed quantitative filter paper, and the precipitate is washed with hot water. When the iron mass fraction >0.050%~3.50%, the sample solution (4.5.4.1) Transfer to the corresponding volumetric flask (V0), if there is insoluble matter, filter with medium-speed quantitative filter paper, wash the precipitate with hot water, and dilute with water to Mark, mix, and then pipette the corresponding volume (V1) of the solution in a 100mL volumetric flask.

4.5.4.3 In a 100mL volumetric flask, add 25mL mixed solution (4.2.9), dilute to the mark with water, and mix. Leave it for 30 minutes. If When the mass fraction of copper in the sample is >=5.0% or the mass fraction of zinc is >=4.0% or the mass fraction of nickel is >=2.0%, or the combined mass fraction of copper, zinc, and nickel >=5%, add 25mL mixed solution (4.2.9), then add 20mL o-phenanthroline solution (4.2.6) (when drawing the working curve, also Correspondingly add 20mL o-phenanthroline solution), dilute to the mark with water, and mix. Leave it for 30 minutes.

4.5.4.4 Move part of the sample solution (4.5.4.3) into the absorption tank, and take the blank test (4.5.3) as a reference. At spectrophotometer wavelength The absorbance was measured at 510.0nm. Find the corresponding iron mass (m1) from the working curve.

4.5.5 Drawing of working curve

4.5.5.1 According to the mass fraction of iron in the sample, the preparation of the series of standard solutions is divided into the following two types.

a) When the iron mass fraction is 0.0010%~0.010%. pipette 0mL, 1.00mL, 2.00mL, 5.00mL, 8.00mL, 10.00mL iron standard solution B (4.2.12), put them in a set of 100mL volumetric flasks, dilute to about 50mL, add 25mL mixed solution (4.2.9), dilute to the mark with water, and mix. Leave for 30min;

b) When the iron mass fraction is >0.010%~3.50%. pipette 0mL, 1.00mL, 2.00mL, 4.00mL, 6.00mL, 8.00mL iron standard solution A (4.2.11), put them in a set of 100mL volumetric flasks, dilute to about 50mL, add 25mL mixed solution (4.2.9), dilute to the mark with water, and mix. Leave it for 30 minutes.

4.5.5.2 Move part of the series of standard solutions (4.5.5.1) into the absorption tank, and use the reagent blank solution (without iron standard solution) as the reference, and The absorbance was measured at a wavelength of 510.0nm with a spectrophotometer. Use iron mass as the abscissa and absorbance as the ordinate to draw the working curve.

4.6 Processing of test data

The iron content is calculated as the mass fraction of iron wFe, calculated according to formula (1).

When the iron mass fraction is less than 1.00%, the calculation result retains two significant digits; when the iron mass fraction is >=1.00%, the calculation result is expressed as small Count the last two digits. Numerical rounding is implemented in 3.2 and 3.3 of GB/T 8170-2008.

4.7 Precision

4.7.1 Repeatability

The measured value of two independent test results obtained under repeatability conditions, within the average range given below, the two test results The absolute difference does not exceed the repeatability limit r, and the case of exceeding the repeatability limit r does not exceed 5%. Repeatability limit r uses linear interpolation according to the data in Table 2 Method or extension method.

4.7.2 Reproducibility

The measured values of two independent test results obtained under reproducibility conditions, within the average range given below, the two test results The absolute difference does not exceed the reproducibility limit R, and the case of exceeding the reproducibility limit R does not exceed 5%. Reproducibility limit R According to the data in Table 3, the linear internal Obtained by interpolation or extension method.

5 Potassium dichromate titration method

5.1 Method summary

In an acidic solution, use potassium dichromate standard titration solution to directly titrate ferrous ions, and excess potassium dichromate will refer to sodium diphenylamine sulfonate. The indicator is oxidized to purple, which is the end point, and the iron content is determined by this.

5.2 Reagents

Unless otherwise stated, only reagents and laboratory tertiary water confirmed to be analytically pure are used in the analysis.

5.2.1 Ammonium fluoride solution (100g/L).

5.2.2 Sulfuric acid-phosphoric acid mixed acid. In 300mL sulfuric acid (13), slowly add 10mL phosphoric acid (rho=1.69g/mL), and mix well.

5.2.3 Potassium dichromate standard titration solution (c=0.015mol/L). Weigh 4.4130g and dry it in an electric oven at 120°C ± 2°C Constant amount of working standard reagent potassium dichromate (relative molecular weight 294.186), placed in a 300mL beaker, dissolved in water, and transferred to 1000mL In a volumetric flask, dilute to the mark with water and mix well.

5.2.4 Sodium diphenylamine sulfonate indicator solution (4g/L).

5.3 Specimen

Process the sample into chips not larger than 1mm.

5.4 Analysis steps

5.4.1 Sample

Weigh the mass (m) as 0.50g sample (5.3), accurate to 0.0001g.

5.4.2 Parallel test

Do two tests in parallel and take the average value.

5.4.3 Determination

5.4.3.1 Place the sample (5.4.1) in a 400mL beaker, add 15mL ammonium fluoride solution (5.2.1), 30mL sulfuric acid-phosphoric acid mixed acid (5.2.2), heat until the sample is completely dissolved, and cool.

5.4.3.2 When the iron mass fraction is 3.50% ~ 40.00%, filter the sample solution (5.4.3.1) with filter paper (or absorbent cotton) in 500 mL In the conical beaker, wash the precipitate 6 to 7 times, and dilute the sample solution to about 150 mL. When the mass fraction of iron is >40.00%~65.00% At the time, filter the sample solution (5.4.3.1) with filter paper (or absorbent cotton) in a 250mL volumetric flask (V2), wash the precipitate 6 to 7 times, dilute with water Release to the mark and mix well. The aliquot volume (V3) is 50.00mL sample solution in a 500mL conical beaker, add 15mL sulfuric acid-phosphoric acid mixture Synthetic acid (5.2.2), diluted to about 150mL.

5.4.3.3 Add 2 to 4 drops of sodium diphenylamine sulfonate indicator solution (5.2.4), and titrate to the solution with potassium dichromate standard titration solution (5.2.3) A steady purple color is the end point. Record the volume (V) of the potassium dichromate standard titration solution (5.2.3) consumed.

5.5 Processing of test data

The iron content is calculated as the mass fraction of iron wFe, calculated according to formula (2).

The calculation result is expressed to two decimal places. The rounding of values shall be implemented in 3.2 and 3.3 of GB/T 8170-2008.

5.6 Precision

5.6.1 Repeatability

The measured value of two independent test results obtained under repeatability conditions, within the average range given below, the two test results The absolute difference does not exceed the repeatability limit r, and the case of exceeding the repeatability limit r does not exceed 5%. Repeatability limit r uses linear interpolation according to the data in Table 4 Method or extension method.

5.6.2 Reproducibility

The measured values of two independent test results obtained under reproducibility conditions, within the average range given below, the two test results The absolute difference does not exceed the reproducibility limit R, and the case of exceeding the reproducibility limit R does not exceed 5%. Reproducibility limit R is linear within Obtained by interpolation or extension method.

6 Test report

The test report should give at least the following aspects.

a) The number, name and method used in this section;

b) All necessary information about identification of samples, laboratory, analysis date, report date, etc.;

c) Express the test results in an appropriate form;

d) Abnormal phenomena during the test;

e) Signatures of review and approval personnel.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 20975.4

EditionTitleRevisionStatus
GB/T 20975.4-2020Methods for chemical analysis of aluminium and aluminium alloys—Part 4:Determination of iron contentcurrent editionCurrent
GB/T 20975.4-2008Methods for chemical analysis of aluminium and aluminium alloys—Part 4:Determination of iron contentprevious editionSuperseded

This page sells the current edition, GB/T 20975.4-2020. Earlier editions are listed for reference only.

How to Download GB/T 20975.4-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 20975.4-2020

$150.00