GB/T 20320-2023Wind energy generation systems - Electrical characteristics measurement and assessment of wind turbines (English PDF)
风能发电系统 风力发电机组电气特性测量和评估方法
This is a limited preview
Buy now to download the full PDF (108 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20320-2023 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Recommended
Issue date
May 23, 2023
Implementation date
December 1, 2023
Scope
GB/T 20320-2023 is the English-translated version of 风能发电系统 风力发电机组电气特性测量和评估方法.
GB/T 20320-2023 — This document specifies the definitions, measurement procedures and evaluation methods of the electrical characteristic parameters of wind turbines: content include: ---Definition and quantitative description of electrical characteristic parameters of grid-connected wind turbines; --- Measurement procedures for quantifying electrical characteristic parameters; --- Grid-connected standard compliance assessment procedures, such as evaluating the power quality of a certain type of wind turbine installed in a specific site: The measurement procedures in this document apply to a single wind turbine connected to the grid in three phases: This document only requires grid-connected wind power the wind turbines are tested and evaluated, but the measurement procedure is applicable to wind turbines of any capacity: The measured characteristic parameters are only valid for the evaluated wind turbine product platform with specific configuration and operation mode: If an item is tested the characteristics are determined by the control parameters and can affect the operating status of the wind turbine, and should be marked in the test report: For example: disconnection of power grid protection the grid level is related to the parameters of the unit, and the test results are only used to verify whether the grid protection function is normal, and there is no need to measure the specific protection value: The designed measurement procedure has nothing to do with the measurement site as far as possible, so as to ensure that the conclusions of the electrical characteristic parameters measured in a certain test site are consistent: Subject to venue restrictions: This document applies to wind turbines that are connected to a frequency-stabilized grid through a point of common connection: Note: In this document, the system voltage level uses the following terms: ---Low voltage (LV), Un<=1kV; ---Medium voltage (MV), 1kV220kV:
Found what you need?
Document preview — GB/T 20320-2023
National Standard of the People's Republic of China
- ICS
- 27.180
- Classification
- F 11
- Replacing
- GB/T 20320-2013
Issued by: State Administration for Market Regulation
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Symbols and units
- 5 Abbreviations
- 6 Wind Turbine Specifications
- 7 Test conditions and test system
- 7.1 General
- 7.2 Overview of test levels
- 7.3 Test validity
- 7.4 Test conditions
- 7.5 Test equipment
- 8 Electrical characteristic measurement and test procedure
- 8.1 General
- 8.2 Power quality test
- 8.3 Steady state operation
- 8.4 Control characteristics
- 8.5 Dynamic performance
- 8.6 Off-grid test
- Appendix A (Informative) Report Format Sample
- A:1 Overview
- A:2 Basic information of test items
- A:3 Power Quality Test
- A:4 Steady-state operation
- A:5 Dynamic performance (see 8.5)
- A:6 Off-grid protection (see 8.6)
- Appendix B (Informative) Voltage Fluctuation and Flicker
- B:1 Continuous operation
- B:2 Switch operation
- B:3 Confirmatory tests for flicker measurement procedures
- B:4 Detailed definition
- Appendix C (Normative) Active Power, Reactive Power and Voltage Measurements
- C:1 General
- C:2 Reference direction according to Generator Practice
- C:3 Calculation of positive, negative and zero sequence components
- Appendix D (Informative) Harmonic Evaluation
- D:1 General principles
- D:2 General analytical methods
- D:3 Determination of harmonic amplitudes affected by space harmonics in DFAG systems
- Appendix E (informative) Wind turbines and wind farm power quality assessment
- E:1 General
- E:2 Voltage fluctuations
- E:3 Current harmonics, interharmonics and high-frequency components
- Appendix F (Informative) Guidelines for Citing Test Results of Different Wind Turbine Generating Sets on the Same Product Platform
- References
- Fig:3 Schematic diagram of virtual grid used for virtual voltage simulation
- Fig:7 Example of PQ curves of wind turbines at different voltage levels
- Fig:16 Positive sequence voltage error band of low voltage disturbance when wind turbine is unloaded
- Figure A:1 Voltage short-term flicker value changes with active power Figure
- Figure A:2 Flicker coefficient changes with active power when the grid impedance phase angle is 30° Figure
- Figure A:3 Flicker coefficient changes with active power when the grid impedance phase angle is 50° Figure
- Figure A:4 Flicker coefficient changes with active power when the grid impedance phase angle is 70° Figure
- Figure A:5 Flicker coefficient changes with active power when the grid impedance phase angle is 85° Figure
- Figure A:9 Time series of starting three-phase voltage effective value at rated active power Figure
- Figure A:10 Time series of starting three-phase current effective value at rated active power Figure
- Figure A:11 Start active power and reactive power time series at rated active power Figure
- Figure A:12 Time series of three-phase voltage effective value when generator 1 is switched to 2 Figure
- Figure A:13 Time series of three-phase current RMS value when generator 1 is switched to 2 Figure
- Figure A:14 Time series of active power and reactive power when generator 1 is switched to 2 Figure
- Figure A:15 Three-phase voltage time series when generator 2 is switched to 1 Figure
- Figure A:16 Three-phase current time series when generator 2 is switched to 1 Figure
- Figure A:17 Time series of active power and reactive power when generator 2 is switched to 1 Figure
- Figure A:18 The maximum value of the 95% quantile of each harmonic current
- Figure A:19 The maximum value of the 95% quantile of harmonic currents between frequencies
- Figure A:20 The maximum value of the 95% quantile of the current high-frequency component at each frequency
- Figure A:21 Power curve
- Figure A:22 Reactive power and active power
- Figure A:23 PQ curve
- Figure A:24 PQ curve at maximum voltage
- Figure A:25 PQ curve at minimum voltage
- Figure A:26 1min average current unbalance degree changes with active power Figure
- Figure A:27 Active power reference value, available power and measured power time during static error evaluation test in active power control mode
- Sequence
- Figure A:28 In the active power control mode, the wind speed time series during the static error evaluation test
- Figure A:29 Active power reference value, available power and measured power time during the settling time test in active power control mode
- Sequence
- Figure A:30 Active power ramp rate limiting test period, available active power and measured active power time series
- Figure A:31 During the active ramp rate limit test, the wind speed time series
- Figure A:32 Time series of available active power and measured active power during the ramp rate limit test
- Figure A:33 During the ramp rate limit test, the wind speed time series
- Figure A:34 Time series of available active power and measured active power during the ramp rate limit test
- Figure A:35 During the ramp rate limit test, the wind speed time series
- Figure A:36 Time series of available active power and measured active power during ramp rate limiting test
- Figure A:37 During the ramp rate limit test, the wind speed time series
- Figure A:38 During grid frequency change, available active power, measured active power and reference active power time series
- Figure A:39 Wind speed time series
- Figure A:40 Measured value of active power changing with frequency
- Figure A:41 During the grid frequency change, available active power, measured active power and reference active power time series
- Figure A:42 Wind speed time series
- Figure A:43 Measured value of active power changing with frequency
- Figure A:44 Test 1: When 0:25Pn 0:8Pn, time series of available active power, measured active power and grid frequency reference value
- Figure A:49 Test 3: When P >0:8Pn, wind speed time series
- Figure A:50 Test 4: When P > 0:8Pn, time series of available active power, measured active power and grid frequency reference value
- Figure A:51 Test 4: When P >0:8Pn, wind speed time series
- Figure A:52 Test 5: when v > vn, time series of available active power, measured active power, grid frequency reference value
- Figure A:53 Test 5: When v > vn, wind speed time series
- Figure A:54 Test 6: When v > vn, time series of available active power, measured active power and grid frequency reference value
- Figure A:55 Test 6: when v > vn, wind speed time series
- Figure A:56 During the reactive power control test, the time series of reactive power reference values and measured values is shown in Figure
- Figure A:57 During reactive power control test, active power time series Figure
- Figure A:58 During the reactive power dynamic response test, the time series of reactive power reference values and measured values Figure
- Figure A:59 During reactive power dynamic response test, active power time series Figure
- Figure A:60 Three-phase voltage waveform during voltage drop/rise when the wind turbine under test is not connected to the grid
- Figure A:61 Three-phase voltage waveform during the recovery period after the voltage drop/rise when the wind turbine under test is not connected to the grid
- Figure A:62 When the wind turbine under test is not connected to the grid, the effective value of the three-phase voltage during the test (one cycle)
- Figure A:63 When the wind turbine under test is not connected to the grid, the positive sequence component of the voltage during the test is
- Figure A:64 Three-phase voltage waveform during voltage drop/rise period when the wind turbine unit under test is connected to the grid
- Figure A:65 Three-phase voltage waveform during the recovery period after the voltage drop/rise when the measured wind turbine is connected to the grid
- Figure A:66 When the tested wind turbine is connected to the grid, the effective value of the three-phase voltage during the test (one cycle)
- Figure A:67 When the wind turbine under test is connected to the grid, the fundamental positive-sequence and negative-sequence voltages during the test period
- Figure A:68 When the tested wind turbine is connected to the grid, the effective value of the three-phase current during the test (one cycle)
- Figure A:69 When the wind turbine under test is connected to the grid, the fundamental positive sequence and negative sequence currents during the test period
- Figure A:70 When the wind turbine under test is connected to the grid, the fundamental positive sequence active power during the test period is
- Figure A:71 When the wind turbine under test is connected to the grid, the fundamental positive sequence reactive power during the test period is
- Figure A:72 When the wind turbine under test is connected to the grid, the fundamental positive-sequence active current during the test period is
- Figure A:73 When the wind turbine under test is connected to the grid, the fundamental positive sequence reactive current during the test period is
- Figure A:74 When the wind turbine under test is connected to the grid, the wind speed or available power during the test
- Figure A:75 Voltage time series during 10s fault reconnection test
- Figure A:76 Time series of active power during 10s fault reconnection test (including recovery phase)
- Figure A:77 Wind speed time series during 10s fault reconnection test
- Figure A:78 Voltage time series during 60s fault reconnection test
- Figure A:79 Active power time series during 60s fault re-connection test (including recovery phase)
- Figure A:80 Wind speed time series during 60s fault reconnection test period
- Figure A:81 Voltage time series during 600s fault reconnection test
- Figure A:82 600s fault reconnection test period (including recovery phase) active power time series
- Figure A:83 Wind speed time series during 600s fault reconnection test period
- Figure B:1 Measurement procedure for wind turbine flicker during continuous operation
- Figure B:2 Measurement procedure for wind turbine voltage variation and flicker during switching operation
- Figure C:1 When the generator convention is adopted, the positive direction of the instantaneous phase current of active power, reactive power and instantaneous phase voltage
- Figure C:2 Example of power phasors in each quadrant corresponding to instantaneous phase voltage and current when the generator convention is adopted
- Figure D:1 Definition of spectral line phase angle under the generator convention (taking the fifth harmonic alphaI5= 120° and alphaU5= 170° as an example, so the fifth
- The harmonic phase angle is phi5= 170°-120°= 50°)
- Figure D:2 Aggregated harmonic amplitude (dotted line) in the 10s interval and the amplitude calculated directly from the DFT10 period window without aggregation (dotted line) compare
- Figure D:3 Comparison of dominant phase angle ratio (PAR)
- Figure F:1 Block diagram of a general-purpose wind turbine (source IEC 61400-27-1)
- Table A:1 Report Basic Information
- Table A:2 main data
- Table A:3 Rated parameters
- Table A:4 Test conditions
- Table A:5 Flicker coefficient of each power range (95% percentile)
- Table A:6 Start 50 when cutting into the wind speed
- Table A:7 Starting at rated active power
- Table A:8 Start-up under the worst working condition when the generator is switched
- Table A:9 Basic test information
- Table A:10 10min harmonic components (95% percentile) in each power range
- Table A:11 Harmonic components (95% percentile) between 10 min in each power range
- Table A:12 10min high-frequency components (95% percentile) in each power range
- Table A:13 Variation of active power with wind speed
- Table A:14 Test data power interval distribution
- Table A:15 Maximum active power
- Table A:16 Reactive power characteristics
- Table A:17 PQ curve
- Table A:18 PQ curve at maximum voltage
- Table A:19 PQ curve at minimum voltage
- Table A:20 P-IUFi
- Table A:21 Basic test information
- Table A:22 static error
- Table A:23 Dynamic response
- Table A:24 Basic test information
- Table A:25 Calculated value of active power ramp rate at startup
- Table A:26 Basic test information
- Table A:27 Start-up, active power ramp rate limit
- Table A:28 Basic test information
- Table A:29 During normal shutdown, active power ramp rate limit
- Table A:30 Basic test information
- Table A:31 During normal operation, active power ramp rate limit
- Table A:32 Basic test information
- Table A:33 When 0:25Pn0:8Pn, test
- Table A:35 Comprehensive inertia test results
- Table A:36 Basic test information
- Table A:37 Static error
- Table A:38 Dynamic response
- Table A:39 Test results when the wind turbine is not connected to the grid
- Table A:40 Test results when wind turbines are connected to the grid
- Table A:41 Voltage protection test results
- Table A:42 Frequency protection test results
- Table A:43 Complete protection circuit test results
- Table A:44 Rate of Change of Frequency (RoCoF) Test Results
- Table A:45 Rate of Change of Frequency (RoCoF) test information
- Table A:46 Re-connection test results
- Table B:1 The rated value of the wind turbine during the confirmatory test
- Table B:2 Relative current fluctuation input value corresponding to flicker coefficient c(psik)=200×(1±5%) when Sk,fic=20Sn
- Table B:3 When Sk,fic=50Sn, relative current change input value corresponding to flicker coefficient c(psik)=200×(1±5%)
- Table B:4 Test specifications for distorted voltages with multiple zero crossings
- Table D:1 Example of measurement results
- Table E:1 Index parameters (IEC TR61000-3-6)
- Table F:1 Main components affecting the electrical performance of wind turbines
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting:
This document replaces GB/T 20320-2013 "Wind Turbine Power Quality Measurement and Evaluation Method", and GB/T 20320-Compared with:2013, in addition to structural adjustments and editorial changes, the main technical changes are as follows:
a) Added "off-grid time", "rated active power", "reactive power capability", "short-circuit ratio", "voltage drop", "voltage increase", "fault wear-through "Over", "Low Voltage Ride Through", "High Voltage Ride Through", "Phasor", "Fundamental Positive Sequence Component", "Fundamental Negative Sequence Component", "Fundamental Zero Sequence Balance", "Control Interface", "Wind Farm", "Assessor", "Time Series", "Short Circuit Capacity", "Percentile", "Comprehensive Inertia", "Static Error", "Response Time", "Stable Time", "Rise Time", "Overshoot", "Reaction Time", "Fall Time", "Recovery Time", "Steady State" "Error Band" "Event Start Time" "Wind Turbine Product Platform" "Component Test" "Subsystem" "Subsystem Test" "Available Active power", "Power factor", "Ramp rate", "Reference value", "Active power range", "Virtual grid", "On-site measurement", "On-site measurement "Test" and "wind speed range" terms and definitions (see 3.3, 3:15, 3:16, 3:20, 3:26, 3:27, 3:28, 3:29, 3:30, 3:31, 3:32, 3:33, 3:34, 3:35, 3:36, 3:37, 3:38, 3:39, 3:40, 3:41, 3:42, 3:43, 3:44, 3:45, 3:46, 3:47, 3:48, 3:49, 3:50, 3:51, 3:52, 3:53, 3:54, 3:55, 3:56, 3:57, 3:58, 3:59, 3:60, 3:61, 3:62, 3:63, 3:64, 3:65, 3:66);
b) The terms and definitions of "common connection point", "power collection system", "rated current", "rated wind speed" and "switching operation" have been changed (see 3.11, 3:12, 3:14, 3:17, 3:21, 3:10, 3:11, 3:13, 3:15, 3:18 of the:2013 edition);
c) Delete the term "rated power" (see 3.14 of the:2013 edition);
d) Added "finertia,recovery" "finertia,trigger" "fsim" "HW" "IUF" "PF" "SW" "Umin" "Umax" "UUVRC" "UOVRC" "Upre" symbol (see Chapter 4);
e) The symbols "fm,i" "fy,i" "Nbin" "Nm,i" "Nm,i,cIntroduction this document provides a unified approach to ensure consistency and accuracy in the reporting, testing and evaluation of electrical characteristics of grid-connected wind turbines:
accuracy: This document will apply to the following parties in the wind power industry:
---Wind turbine manufacturers, providing wind turbines that meet the requirements of electrical characteristics;
--- Wind turbine owners, specify the requirements for the electrical characteristics of wind turbines;
--- The operator of the wind turbine, confirming the compliance of the specification or electrical characteristics of the wind turbine;
---Wind turbine planning supervision department, accurately and fairly judges that the installation process of wind turbines meets the design requirements, voltage quality meet deadline;
---Wind turbine certification testing agency, to evaluate the electrical characteristics of this type of wind turbine;
---The power grid planning and dispatching department has the right to decide whether the wind turbines can be connected to the grid:
This document provides measurement and evaluation methods for the electrical characteristics of grid-connected wind turbines, which will be beneficial to the production and installation of wind turbines Planning, licensing, operation, use, testing and commissioning: All parties involved in the wind power industry should use the measurement and analysis techniques described in this document, to ensure consistency and accuracy in the continued development and operation of wind turbines:
The measurement and analysis procedures in this document ensure consistency of test results: Any part of the test content can be carried out independently and issued Report:
Electrical Characteristics of Wind Turbines in Wind Power Generation System Measurement and Evaluation Methods
1 Scope
This document specifies the definitions, measurement procedures and evaluation methods of the electrical characteristic parameters of wind turbines: content include:
---Definition and quantitative description of electrical characteristic parameters of grid-connected wind turbines;
--- Measurement procedures for quantifying electrical characteristic parameters;
--- Grid-connected standard compliance assessment procedures, such as evaluating the power quality of a certain type of wind turbine installed in a specific site:
The measurement procedures in this document apply to a single wind turbine connected to the grid in three phases: This document only requires grid-connected wind power the wind turbines are tested and evaluated, but the measurement procedure is applicable to wind turbines of any capacity:
The measured characteristic parameters are only valid for the evaluated wind turbine product platform with specific configuration and operation mode: If an item is tested the characteristics are determined by the control parameters and can affect the operating status of the wind turbine, and should be marked in the test report: For example: disconnection of power grid protection the grid level is related to the parameters of the unit, and the test results are only used to verify whether the grid protection function is normal, and there is no need to measure the specific protection value:
The designed measurement procedure has nothing to do with the measurement site as far as possible, so as to ensure that the conclusions of the electrical characteristic parameters measured in a certain test site are consistent:
Subject to venue restrictions:
This document applies to wind turbines that are connected to a frequency-stabilized grid through a point of common connection:
Note: In this document, the system voltage level uses the following terms:
---Low voltage (LV), Un<=1kV;
---Medium voltage (MV), 1kV220kV:
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text: Among them, dated references for documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document:
IEC TR61000-3-7 Electromagnetic Compatibility (EMC) Part 3-7: Limits for installation in medium-voltage, high-voltage and extra-high voltage power systems IEC 61000-4-7:2002/AMD1.2008 Electromagnetic Compatibility (EMC) Part 4-7: Testing and Measurement Techniques for Power Supply Systems Note: GB/T 17626.7-2017 Electromagnetic Compatibility Test and Measurement Technology Power Supply System and Connected Equipment Harmonic and Interharmonic Measurement and Measuring Instrument Guide Then (IEC 61000-4-7:2009, IDT) IEC 61000-4-15:2010 Electromagnetic Compatibility (EMC) Part 4-15: Test and Measurement Techniques Flicker Meter Function and Design
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 108 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 61000
Cited by
- GB/T 43904-2024Wind energy generation systems - Operation evaluation index system for wind turbines
- GB/Z 44528-2024Wind energy generation systems - Measurement and assessment of electrical characteristics - Wind turbine harmonic model and its application
- GB/T 18451.1-2022Wind energy generation systems—Design requirements
- GB/T 41512-2022Distributed wind energy generation systems
- GB/T 25386.2-2021Wind turbines—Control system—Part 2: Test method
- GB/T 37819-2019Bi-circulation power generation unit for low-temperature waste heat recovery
How to Download GB/T 20320-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17626.7-2017 — Electromagnetic compatibility -- Testing and measurement techniques -- General guide on harmonics and inter-harmonics measurements and instrumentation, for power supply systems and equipment connected thereto
GB/T 18088-2026 — Sampling for entry and exit animal quarantine
GB/T 47983-2026 — Technical requirements for on-board energy consumption monitoring of passenger cars
Secure payment via Stripe
Payments accepted
GB/T 20320-2023
$1,475.00