GB/T 20108-2017Low temperature unitary air conditioner (English PDF)
低温单元式空调机
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20108-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 12, 2017
Implementation date
February 1, 2018
Scope
GB/T 20108-2017 is the English-translated version of 低温单元式空调机.
GB/T 20108-2017 covers low temperature unitary air conditioners, the units that treat air for enclosed spaces with an inlet air temperature between 5 °C and 18 °C, typically in process environments.
It applies to units with a nominal cooling capacity of 7 000 W or more. The standard sets out terms and definitions such as cooling capacity, cooling power consumption and cooling energy efficiency ratio, then types, model designation and basic parameters.
It lays down general and safety requirements and performance requirements, the matching test methods and instruments, factory and sampling inspection rules, and marking, packaging, transportation and storage.
Annexes give the model designation method and temperature distribution coefficients for a number of cities. It replaces GB/T 20108-2006, was issued on 12 July 2017 and has applied since 1 February 2018.
Found what you need?
Document preview — GB/T 20108-2017
National Standard of the People's Republic of China
- ICS
- 27.200
- Classification
- J 73
- Replacing
- GB/T 20108-2006
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Terms and definitions
- 4 type, model and basic parameters
- 5 requirements
- 6 Test Method
- 7 Inspection rules
- Marking, packaging, transportation and storage
- Appendix A (informative) Low temperature unit type air conditioner model representation method
- Appendix B (informative) Partial urban temperature distribution coefficient
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 20108-2006 "low temperature unit type air conditioner". Compared with GB/T 20108-2006, the main changes are as follows.
--- increase the cooling capacity, cooling power consumption, the annual energy efficiency ratio (AEER), air volume, standard air volume, cold air ratio definition (see 3.2, 3.3, 3.5, 3.6, 3.7, 3.8);
- the definition of terminology for the removal of cryogenic conditions;
- modified type classification (see 4.1, 4.2);
--- modified the basic parameters (see 4.3.1, 4.3.2);
- Increased air volume, condensate and condensate removal, yearly energy efficiency (AEER) test conditions and test requirements (see 4.3.3, 5.3.7, 5.3.8, 5.3.13, 6.3.11);
- increased water pressure drop, annual energy efficiency ratio, cold wind ratio requirements and limits (see 5.3.12, 5.3.13, 5.3.14);
- modified general requirements and safety requirements (see 5.1, 5.2);
--- increase the instrument type and accuracy, test conditions parameters of the reading tolerance (see 6.1.4,6.1.5,6.1.6,6.1.7);
- modified test requirements (see 6.2);
- the removal of energy efficiency and minimum load conditions and their corresponding test requirements;
- modified factory inspection and sampling inspection requirements (see 7.1, 7.2);
- modified mark, packaging, transport and storage requirements (see 8.1, 8.2, 8.3);
--- modified the low temperature unit type air conditioner model number in Appendix A (see Appendix A);
- increase the urban temperature distribution coefficient (see Appendix B).
1 Scope
This standard specifies the terms and definitions, types, types and basic parameters of low temperature unit air conditioners (hereinafter referred to as "low temperature air conditioners"), Requirements, test methods, inspection rules, marking, packaging, transportation and storage.
This standard applies to the nominal cooling capacity greater than or equal to 7000W, for the process environment, the inlet temperature range of 5 °C ~ 18 °C low Temperature unit air conditioner.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 191 packaging and storage icon
GB/T 2828.1 Sampling inspection procedures Part 1: Batch inspection sampling plan for retrieval by quality limit (AQL)
GB/T 6388 shipping package collection and delivery mark
GB/T 13306 signs
GB/T 17758-2010 Elemental air conditioners
GB 25130 Unit type air conditioner safety requirements
JB/T 7249 refrigeration equipment terminology
3 Terms and definitions
The following terms and definitions are defined in JB/T 7249 and are applicable to this document.
3.1 Low temperature unit type air conditioner
For the air inlet temperature between 5 °C ~ 18 °C to the enclosed space to provide the treatment of air equipment. It mainly includes refrigeration systems as well Air circulation and air filtering devices, and may also include heating and humidifying means.
3.2 Cooling capacity
Under the specified cooling capacity test, the sum of the heat removed from the enclosed space, room or area during the unit time of the low temperature air conditioner.
Note: The unit of cooling capacity is watts (W).
3.3 Cooling power consumption
In the specified cooling capacity test, low-temperature air-conditioning operation of the power consumed.
Note: The unit of cooling power consumption is watts (W).
3.4 Cooling energy efficiency ratio (EER)
In the specified cooling capacity test, the low temperature air conditioning machine cooling capacity and cooling power consumption ratio.
Note: The value of the cooling energy efficiency ratio is expressed in W/W.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 2828.1Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 6388Transport package shipping mark
- GB/T 13306Plates
- GB/T 17758-2010Unitary air conditioners
- GB 25130Safety requirements for unitary air-Conditioners
Similar standards
Editions of GB/T 20108
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 20108-2017 | Low temperature unitary air conditioner | current edition | Current |
| GB/T 20108-2006 | Low temperature unitary air conditioner | previous edition | Superseded |
This page sells the current edition, GB/T 20108-2017. Earlier editions are listed for reference only.
How to Download GB/T 20108-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 25130-2010 — Safety requirements for unitary air-Conditioners
GB/T 13306-2011 — Plates
GB/T 17758-2010 — Unitary air conditioners
Secure payment via Stripe
Payments accepted
GB/T 20108-2017
$235.00