GB/T 19882.223-2017Automatic meter reading system—Part 223: Data link layer (MAC sub-layer)—Wireless communication meter reading system (English PDF)
自动抄表系统 第223部分:无线通信抄表系统 数据链路层(MAC子层)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 19882.223-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 29, 2017
Implementation date
July 1, 2018
Scope
GB/T 19882.223-2017 is the English-translated version of 自动抄表系统 第223部分:无线通信抄表系统 数据链路层(MAC子层).
GB/T 19882.223-2017 defines the data link layer, specifically the MAC sub-layer, used by wireless communication automatic meter reading systems. It specifies the MAC frame format, the basic channel access model, the services the MAC sub-layer provides and their primitives, and the security certification scheme.
The protocol follows IEEE 802.15.4e, keeping its beacon mechanism, PAN establishment process and CSMA-CA channel access, while leaving out the dormancy mode and GTS.
The document also covers information elements, MAC commands, superframe configuration, beacon generation, MAC data services, constants and PIB attributes, plus a protocol implementation conformance statement.
It applies to mains-powered micro-power wireless data acquisition systems and not to battery-powered devices. It was issued on 29 December 2017 and has applied since 1 July 2018.
Found what you need?
Document preview — GB/T 19882.223-2017
National Standard of the People's Republic of China
- ICS
- 17.220.20
- Classification
- N 22
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Definitions and terms, acronyms
- 3.1 Terms and definitions
- 3.2 Abbreviations
- 4 General Description
- 5 MAC protocol
- 5.1 Overview
- 5.2 MAC Function Description
- 5.3 MAC frame format
- 5.4 Information Element
- 5.5 MAC Command
- 6 MAC Services
- 6.1 Overview
- 6.2 Communication Notification Primitives
- 6.3 Channel Scanning primitives
- 6.4 Update primitives for super-frame configuration
- 6.5 Beacon Generation Primitives
- 6.6 MAC Data Services
- 6.7 MAC Constants and PIB Attributes
- 7 Security
- 8 Protocol Implementation Declaration of Conformity (PICS)
Foreword
GB/T 19882 "automatic meter reading system" is divided into the following 11 parts.
--- General
--- Part 3-1. Application Layer Data Exchange Protocol object identification system;
--- Part 3-2. Application layer data exchange protocol interface class;
--- Part 3-3. Application layer data exchange protocol COSEM application layer;
--- Part 211. System requirements for low-voltage power line carrier meter reading system;
--- Part 212. Low-voltage power line carrier meter reading system carrier concentrator;
--- Part 213. Low-voltage power line carrier meter reading system carrier acquisition;
--- Part 214. Low voltage power line carrier meter reading system Static carrier energy meter special requirements;
--- Part 221. Wireless communication meter reading system system requirements;
--- Part 222. Physical layer specification of wireless communication meter reading system;
--- Part 223. Wireless communication meter reading system data link layer (MAC sublayer).
This section GB/T 19882.223 Part 223.
This section drafted in accordance with GB/T 1.1-2009 given rules.
Introduction
The MAC sub-layer defined in this part of ISO 9001 shall be IEEE802.15.4e compliant with beacon mechanism and PAN establishment process that IEEE802.15.4e agreement stipulates, but does not support dormancy mode. At the same time this part supports IEEE802.15.4e agreement The defined channel accesses CSMA-CA mechanisms and enhanced LEs but does not support GTS mode.
1 Scope
This section GB/T 19882 specifies the MAC layer protocol frame format, the basic model of channel access, MAC sub-layer to provide the basic Service and MAC sub-layer of the service primitives and security certification system.
This section applies to power-based micro-power wireless information acquisition system. This section supports only the power supply equipment, does not apply to Battery powered device.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 19882.222-2017 Automatic meter reading system - Part 222: Physical layer specification of wireless communication meter reading system
IEEE802.15.4-2011TM IEEE Standard for Local and Metro Networks Part 15.4. Low Speed Wireless Personal Area Networks (LR- WPAN) [IEEE ExTA for Portland Metropolitan Networks Network Part 15.4. Low-Rate Wireless Per-sionalAreaNetWorks (LR-WPANs)]
IEEE802.15.4e-2012TM IEEE Standard for Local and Metro Networks Part 15.4. Low-Speed Wireless Personal Area Networks (LR-WPAN) Amendment 1. MAC sublayer [IEEE Extensions for Local and Metropolitan Networks Network Part 15.4. Low-Rate Wireless Regional Area Network (LR-WPANs) Amendment 1. MACsublayer]
3 Definitions and terms, acronyms
3.1 Terms and definitions
IEEE 802.15.4-2011 (TM), IEEE 802.15.4e-2012 (TM), and the following terms and definitions apply to this document. for For ease of use, the following list repeatedly lists some of the terms and definitions in IEEE 802.15.4-2011 (TM), IEEE 802.15.4e-2012 (TM).
3.1.1 Association
A service used to establish membership in a network for devices. [IEEE Std 802.15.4-2011, Definition 3.1]
3.1.2 Authentication tag
Acknowledge message reliability verification information. [IEEE Std 802.15.4-2011, Definition 3.1]
3.1.3 Beacon-enabled personal area network
All coordinators periodically send a beacon of PAN. [IEEE Std 802.15.4-2011, Definition 3.1]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 19882.223-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19882.222-2017 — Automatic meter reading system—Part 222: Physical layer(PHY) specifications—Wireless communication meter reading system
GB/T 19882.211-2010 — Automatic meter reading system - Part 211: Distribution line carrier meter reading system - System requirements
GB/T 19882.212-2012 — Automatic meter reading system - Part 212: Distribution line carrier meter reading system - DLC Concentrator
Secure payment via Stripe
Payments accepted
GB/T 19882.223-2017
$235.00