GB/T 19212.11-2020Safety of transformers, reactors, power supply units and combinations thereof - Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V (English PDF)

Also coversGBT19212.11-2020

Open the GB/T 19212.11-2020 preview as PDF

Preview — first pages of GB/T 19212.11-2020

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

December 14, 2020

Implementation date

July 1, 2021

Scope

GB/T 19212.11-2020 (Safety of transformers, reactors, power supply units and combinations thereof - Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V) is available as an English-translated PDF.

GB/T 19212.11-2020 — This chapter of GB/T 19212:1-2016 is replaced by the following: This part of GB/T 19212 specifies the safety of separation transformers with high insulation level and separation transformers with an output voltage exceeding 1000V: All requirements: Transformers with electronic circuits are also included in this section: Note 1: Safety requirements include electrical, temperature and mechanical aspects: Unless otherwise specified, the following "transformers" include high insulation level separation transformers and output voltages exceeding AC 1000V or DC 1500V separation transformer: This section applies to standing or mobile, single-phase or multi-phase, air cooling (natural cooling or forced cooling), independent or supporting dry transformer: The winding can be encapsulated or non-encapsulated: This section applies to transformers and power supply devices (linear) whose internal operating frequency does not exceed 500Hz: When this part is used in combination with GB/T 19212:17 switching power supply device, it is also applicable to the internal working frequency of more than 500Hz: Power supply unit: When the requirements of the two standards are inconsistent, the stricter standard is preferred: This section applies to the rated power supply voltage not exceeding 1000V AC, the rated power supply frequency and internal working frequency not exceeding 500Hz: This section applies to the rated output not exceeding: ---For single-phase transformer, it is 25kVA; ---For multi-phase transformers, it is 40kVA: If the purchaser and the manufacturer agree otherwise, this section also applies to transformers that do not limit the rated output: This section applies to no-load output voltage or rated output voltage: ---For high insulation level separation transformer, no more than AC 1000V or DC 1500V; ---For the separation transformer with output voltage exceeding 1000V, it exceeds AC 1000V or DC 1500V and does not exceed AC or DC 15000V: This section does not apply to: --- Transformer included in GB/T 1094:11; ---GB/T 19149 neon lamp transformer; ---IEC 61347-2-10 related or supporting power supply and converter: This section does not apply to external circuits and their components that are scheduled to be connected to the input terminals and output terminals of the transformer: When installation regulations or final product standards do not require double insulation or reinforced insulation between circuits, the changes included in this section can be used: Depressor: Note 2: Generally, the transformer is scheduled to be used in conjunction with the equipment to provide a voltage different from the power supply voltage to meet the functional requirements of the equipment: Its electric shock protection can It can be provided (or realized) through other parts of the supporting equipment, such as the housing: Parts of the output circuit can be connected to the input circuit or protection Ground: This section applies to transformers supporting special equipment, and its scope is determined by relevant standards: Note 3: Note the following:

Document preview — GB/T 19212.11-2020

National Standard of the People's Republic of China

ICS
29.180
Classification
K 41

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • 1 Scope1
  • 2 Normative references2
  • 3 Terms and definitions2
  • 4 General requirements2
  • 5 General description of the test3
  • 6 Rating3
  • 7 Category3
  • 8 Signs and other information3
  • 9 Electric shock protection5
  • 10 Change of input voltage setting value5
  • 11 Load output voltage and output current5
  • 12 No-load output voltage5
  • 13 Short circuit voltage6
  • 14 Fever6
  • 15 Short circuit and overload protection6
  • 16 Mechanical strength6
  • 17 Protection against harmful entry of dust, solid foreign objects and moisture6
  • 18 Insulation resistance, dielectric strength and leakage current6
  • 19 Structure7
  • 20 Components8
  • 21 Internal wiring8
  • 22 Power connection and other external flexible cables or cords8
  • 23 External wire terminal8
  • 24 Protective earthing device8
  • 25 Screws and connections8
  • 26 Creepage distance, electrical clearance and penetration distance8
  • 27 Heat resistance, flame resistance and tracking resistance10
  • 28 Rust prevention10
  • Appendix11
  • Reference12
  • Table 101 Output voltage difference6
  • Table 102 Dielectric strength test voltage value and its voltage applied part7
  • Table 103 Uniform electric field or non-uniform electric field clearance9
  • Table 104 Creepage distance of basic insulation or supplementary insulation for material group IIIa, II and I (CTI >175)9

Foreword

GB/T 19212 "Safety of Transformers, Reactors, Power Supply Devices and Their Combinations" 1) consists of the following parts:

1) In this series of standards, some parts are under the heading "Safety of power transformers, power supplies, reactors and similar products", and some parts are

Under the heading of 1100V and below the safety of transformers, reactors, power supply units and similar products, some parts are

Under the heading of "Safety of Source Device and Its Combination", the title of this series of standards may be revised in the future:

---Part 1: General requirements and tests;

---Part 2: Special requirements and tests for general purpose separating transformers and power supplies with built-in separating transformers;

---Part 3: Special requirements and tests for control transformers and power supplies with built-in control transformers;

---Part 4: Special requirements and tests for ignition transformers for gas and oil burners;

---Part 5: Special requirements and tests for isolation transformers and power supply devices with built-in isolation transformers;

---Part 6: Special requirements and tests for transformers for shavers, power supply devices for shavers, and power supply devices for shavers;

---Part 7: Special requirements and tests for safety isolating transformers and power supply devices with built-in safety isolating transformers;

---Part 8: Special requirements and tests for transformers and power supplies for toys;

---Part 9: Special requirements and tests for transformers and power supply devices for electric bells and electric clocks;

---Part 10: Special requirements and tests for transformers and power supply devices for class III portable tungsten filament lamps;

---Part 11: Special requirements and tests for separating transformers with high insulation level and separating transformers with an output voltage exceeding 1000V;

---Part 13: Special requirements and tests for constant voltage transformers and power supply devices;

---Part 14: Special requirements and tests for autotransformers and power supply devices with built-in autotransformers;

--- Part 15: Special requirements and tests for voltage regulators and power supply devices with built-in voltage regulators;

---Part 16: Special requirements and tests for isolation transformers for power supply in medical places;

---Part 17: Special requirements and tests for switching power supply devices and transformers for switching power supply devices;

---Part 20: Special requirements for interference attenuation transformers;

---Part 21: Special requirements and tests for small reactors;

---Part 24: Special requirements for transformers used on construction sites;

--- Part 27: Special requirements and tests for transformers and power supply devices for energy saving and other purposes:

This part is Part 11 of GB/T 19212:

This section was drafted in accordance with the rules given in GB/T 1:1-2009:

This part uses the redrafting law to amend and adopt IEC 61558-2-10:2014 "Safety of Transformers, Reactors, Power Supply Units and Their Combinations"

Full Part 2-10: Special requirements and tests for separating transformers with high insulation levels and separating transformers with output voltages exceeding 1000V:

The technical differences between this part and IEC 61558-2-10:2014 and the reasons are as follows:

---Regarding normative reference documents, this section has made adjustments with technical differences to adapt to my country's technical conditions or facilitate the use of

The conditions of application and adjustment are collectively reflected in Chapter 2 "Normative Reference Documents": The specific adjustments are as follows:

* The technical differences between GB/T 19212:1-2016 and IEC 61558-1:2009 in Chapter 2 are retained to facilitate the

GB/T 19212:1-2016 supporting use;

* Replace IEC 61558- with GB/T 19212:1-2016 and GB/T 19212:17 which are modified and adopted international standards:

1:2005 (including its No: 1 amendment) and IEC 61558-2-16;

* Added reference to IEC 60417-DB (see Chapter 8):

--- Amend "creepage distance, electrical clearance and penetration distance" in the original text 26:1 to "electrical clearance"; change the original text 26:1:101

The "creepage distance, electrical clearance and penetration distance" in "Creepage distance" is modified to "creepage distance" to meet the actual situation in my country:

This section also made the following editorial changes:

---In order to meet the uniform numbering of the GB/T 19212 series of standards, the standard name is changed to "transformers, reactors, power supply devices and their

Combined safety Part 11: Characteristics of high-insulation level separation transformers and separation transformers with an output voltage exceeding 1000V

Special requirements and tests";

---Introduction is added in Chapter 2 and Chapter 3;

--- Amend Table 102 in Note 2 of 26:1 to Table 103;

--- Delete the sentence below Note 2 and Note 7 in the original text 26:1, because it is consistent with the content in GB/T 19212:1-2016

repeat;

---Adjust the original table 103 to 26:1;

---Move the "altitude not exceeding:2000m" in Note 3 of the original table 104 to the header, and delete the contents of Note 3 and Note 2;

---Change the IEC 60076-11 and IEC 61050 in the references to the corresponding national standards:

This part was proposed by China Electrical Equipment Industry Association:

This part is organized by the National Standardization Technical Committee (SAC/TC418) for small power transformers, reactors, power supply devices and similar products

Focus:

Drafting organizations of this section: Shenyang Transformer Research Institute Co:, Ltd:, Beijing Tairuite Testing Technology Service Co:, Ltd:, Tongling

Sanjia Transformer Technology Co:, Ltd:, Shanghai Institute of Quality Supervision and Inspection Technology, Zhongshan Baolijin Electronics Co:, Ltd:, Industrial and

Saibao Quality and Safety Testing Center of the Fifth Institute of Electronics, Ministry of Information Technology, Shanghai Entry-Exit Inspection and Quarantine Bureau Mechanical and Electrical Products Testing Technology Center, Tianjin

Optoelectronics Huigao Electronics Co:, Ltd:, Wenzhou Chint Power Electric Co:, Ltd:, Mingzhu Electric Co:, Ltd:

Introduction

This part is formulated on the basis of GB/T 19212:1-2016, and this part needs to be used in conjunction with GB/T 19212:1-2016:

This part is to supplement and modify the corresponding chapters and articles of GB/T 19212:1-2016

The content is transformed into the content of this section:

This section is numbered starting from 101 for the newly added content of GB/T 19212:1-2016:

Safety of transformers, reactors, power supply devices and their combinations

Part 11: High insulation level separation transformer and

Separation transformer with output voltage exceeding 1000V

Special requirements and tests

1 Scope

This chapter of GB/T 19212:1-2016 is replaced by the following:

This part of GB/T 19212 specifies the safety of separation transformers with high insulation level and separation transformers with an output voltage exceeding 1000V:

All requirements: Transformers with electronic circuits are also included in this section:

Note 1: Safety requirements include electrical, temperature and mechanical aspects:

Unless otherwise specified, the following "transformers" include high insulation level separation transformers and output voltages exceeding AC 1000V or DC

1500V separation transformer:

This section applies to standing or mobile, single-phase or multi-phase, air cooling (natural cooling or forced cooling), independent or supporting dry

transformer: The winding can be encapsulated or non-encapsulated:

This section applies to transformers and power supply devices (linear) whose internal operating frequency does not exceed 500Hz:

When this part is used in combination with GB/T 19212:17 switching power supply device, it is also applicable to the internal working frequency of more than 500Hz:

Power supply unit: When the requirements of the two standards are inconsistent, the stricter standard is preferred:

This section applies to the rated power supply voltage not exceeding 1000V AC, the rated power supply frequency and internal working frequency not exceeding 500Hz:

This section applies to the rated output not exceeding:

---For single-phase transformer, it is 25kVA;

---For multi-phase transformers, it is 40kVA:

If the purchaser and the manufacturer agree otherwise, this section also applies to transformers that do not limit the rated output:

This section applies to no-load output voltage or rated output voltage:

---For high insulation level separation transformer, no more than AC 1000V or DC 1500V;

---For the separation transformer with output voltage exceeding 1000V, it exceeds AC 1000V or DC 1500V and does not exceed AC or

DC 15000V:

This section does not apply to:

--- Transformer included in GB/T 1094:11;

---GB/T 19149 neon lamp transformer;

---IEC 61347-2-10 related or supporting power supply and converter:

This section does not apply to external circuits and their components that are scheduled to be connected to the input terminals and output terminals of the transformer:

When installation regulations or final product standards do not require double insulation or reinforced insulation between circuits, the changes included in this section can be used:

Depressor:

Note 2: Generally, the transformer is scheduled to be used in conjunction with the equipment to provide a voltage different from the power supply voltage to meet the functional requirements of the equipment: Its electric shock protection can

It can be provided (or realized) through other parts of the supporting equipment, such as the housing: Parts of the output circuit can be connected to the input circuit or protection

Ground:

This section applies to transformers supporting special equipment, and its scope is determined by relevant standards:

Note 3: Note the following:

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

How to Buy GB/T 19212.11-2020

  1. 1Add to cart. Click the "Buy GB/T 19212.11-2020" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19212.11-2020

$260.00

$220.00for partners