GB/T 18279.2-2015Sterilization of health care products -- Part 2: Guidance on the application of GB 18279.1 (English PDF)
医疗保健产品的灭菌环氧乙烷 第2部分:GB 18279.1应用指南
This is a limited preview
Buy now to download the full PDF (35 pages)
Need quotation for your management?
Get a formal quotation for GB/T 18279.2-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
December 10, 2015
Implementation date
July 1, 2017
Scope
GB/T 18279.2-2015 is the English-translated version of 医疗保健产品的灭菌环氧乙烷 第2部分:GB 18279.1应用指南.
GB/T 18279.2-2015 — This Part of GB 18279 provides guidance for the requirements in GB 18279.1-2015.It does not repeat the requirements and is not intended to be used in isolation. The exclusions in GB 18279.1 apply also to this Part.
Found what you need?
Document preview — GB/T 18279.2-2015
National Standard of the People's Republic of China
- ICS
- 11.080.01
- Classification
- C 47
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...3
- Introduction...5
- 1 Scope...6
- 2 Normative references...6
- 3 Terms and definitions...7
- 4 Quality management systems...8
- 5 Sterilizing agent characterization...9
- 6 Process and equipment characterization...9
- 7 Product definition...11
- 8 Process definition...17
- 9 Validation...21
- 10 Routine monitoring and control...31
- 11 Product release from sterilization...34
- 12 Maintaining process effectiveness...35
Foreword
GB 18279 "Sterilization of health care products" consists of the following parts.
- Part 1.Requirements for development, validation and routine control of a
sterilization process for medical devices;
- Part 2.Guidance on the application of GB 18279.1.
This Part is Part 2 of GB 18279.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part together with GB 18279.1 replaces GB 18279-2000 "Medical devices.
Validation and routine control of ethylene oxide sterilization".
This Part identically uses ISO/TS 11135-2.2008 "Sterilization of health care products -
Part 2.Guidance on the application of ISO 11135-1".
The Chinese documents which have consistency with the international normative
reference in this Part are as follows.
- GB 18282.1-2015, Sterilization of health care products - Chemical indicator - Part
1 General requirements (ISO 11140-1.2005, IDT);
- GB/T 19973.1-2015, Sterilization of medical devices - Microbiological methods -
Part 1.Determination of a population of microorganisms on products (ISO 11737-
1.2006, IDT);
- YY/T 0287-2003, Medical devices. Quality management systems. Requirements
for regulatory purposes (ISO 13485.2003, IDT);
- YY/T 0802-2010, Sterilization of medical devices. Information to be provided by
the manufacturer for the processing of resterilizable medical devices (ISO
17664.2004, IDT).
This Part made the following editorial changes.
- Some editorial modifications have been made in accordance with the requirements
of GB/T 1.1;
- The foreword of ISO/TS 11135-2.2008 is deleted;
- Some international standards appearing in the introduction and references are
replaced by corresponding Chinese standards.
Attention is drawn to the possibility that some of the elements of this document may be
the subject of patent rights. The issuing authority shall not be held responsible for
identifying any or all such patent rights.
This Part was proposed by China Food and Drug Administration.
This Part shall be under the jurisdiction of National Technical Committee on
Disinfection Technology and Equipment of Standardization Administration of China
(SAC/TC 200).
The drafting organizations of this Part. Hangzhou Unique Disinfection Equipment Co.,
Ltd., Guangzhou Medical Device Quality Supervision and Inspection Center of the
State Food and Drug Administration, Terumo Medical Products (Hangzhou) Co., Ltd.,
Guangzhou Yangpu Medical Technology Co., Ltd., Shijie Medical Technology
(Shanghai) Co., Ltd.
Main drafters of this Part. Chen Zhiling, Zhou Qingqing, Hu Changming, Lin Yuqing,
Weng Hui, Gong Yaoren, Gao Li, Min Jie, Xu Haiying.
Version of standard substituted by this Part is.
- GB 18279-2000.
1 Scope
This Part of GB 18279 provides guidance for the requirements in GB 18279.1-2015.It
does not repeat the requirements and is not intended to be used in isolation.
The exclusions in GB 18279.1 apply also to this Part.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
person with knowledge of the sterilization technology being utilized and its effects upon
materials and microorganisms
4 Quality management systems
It is recommended that the identity of the person who assembled the pack also be
included on the identifier, to allow for further investigation if a problem should arise.
Lot identification information enables personnel to retrieve items in the event of a recall
and to trace problems to their source.
5 Sterilizing agent characterization
EO is a highly penetrative gas that will permeate most packaging materials and
polymeric materials. Widely recognized compositions include 100% EO and blends
with carbon dioxide or nitrogen. The storage conditions for EO should be in accordance
with the EO manufacturer's recommendations and all applicable regulations.
6 Process and equipment characterization
In health care facilities, process and equipment characterization are generally the
responsibility of the sterilizer manufacturer.
The equipment specification should be reviewed to ensure that regulatory and safety
requirements are met, technical specifications are appropriate, and services and
infrastructure necessary to operate the equipment are available.
7 Product definition
The demonstration that the specified sterilization process does not affect the
correct functioning of the product may be accomplished by performing functionality
tests, or other appropriate tests, on the medical device and packaging following
sterilization. These tests may range from a simple visual inspection to a battery of
specialized tests.
8 Process definition
If the medical device or packaging manufacturer supplies instructions for reprocessing
that are not specific enough or not appropriate (e.g., an EO process with 100 % EO,
where the health care facility uses a blend), the facility should either perform a
validation or assess the appropriateness of its own reprocessing method, based on
materials effect data and reprocessing instructions for other devices.
9 Validation
PQ consists of rigorous microbiological and physical testing, beyond routine
monitoring, to demonstrate the efficacy and reproducibility of the sterilization process.
PQ is normally not started until after completion and approval of the IQ and OQ testing.
Acceptance criteria should include conformance with the specifications for the
sterilization process parameters and microbiological challenge.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 35 pages — is available in the English PDF.
Referenced standards
Cited by
- YY/T 0500-2021Cardiovascular implants and extracorporeal systems. vascular prostheses. tubular vascular grafts and vascular patches
- YY/T 0567.2-2021Aseptic processing of health care products - Part 2: Sterilizing filtration
- YY/T 0726-2020Instrumentation for use in association with non-active surgical implants - General requirements
- YY/T 1698-2020Medical devices for human assisted reproductive technology in vitro—Assisted reproduction aspiration needles
- YY/T 1718-2020Medical devices for human assisted reproductive technology in vitro—Embryo transfer catheters
- YY/T 1403-2017Requirements of contract sterilization using ethylene oxide
How to Download GB/T 18279.2-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 18279.2-2015
$475.00