GB/T 1819.14-2017Methods for chemical analysis of tin concentrates—Part 14: Determination of copper content—Flame atomic absorption spectrometry (English PDF)
锡精矿化学分析方法 第14部分:铜量的测定 火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 1819.14-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 29, 2017
Implementation date
April 1, 2018
Scope
GB/T 1819.14-2017 is the English-translated version of 锡精矿化学分析方法 第14部分:铜量的测定 火焰原子吸收光谱法.
GB/T 1819.14-2017 is Part 14 of the GB/T 1819 series of methods for the chemical analysis of tin concentrates, and determines their copper content by flame atomic absorption spectrometry over a range of 0.005 % to 2.00 %.
The sample is decomposed with hydrochloric and nitric acid, and the absorbance of copper is measured in a dilute hydrochloric acid medium with an air-acetylene flame at 324.7 nm.
The standard lists the reagents, including the copper standard stock and working solutions, and the performance the atomic absorption spectrometer must reach for characteristic concentration, precision and linearity of the working curve; the sample particle size must not exceed 0.074 mm.
Compared with the previous edition it revises the precision clause and adds the test report. It replaces GB/T 1819.14-2006, was issued on 29 September 2017 and has applied since 1 April 2018.
Found what you need?
Document preview — GB/T 1819.14-2017
National Standard of the People's Republic of China
- ICS
- 73.060
- Classification
- D 41
- Replacing
- GB/T 1819.14-2006
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagent
- 4 Instruments
- 5 Sample
Foreword
GB/T 1819 "tin concentrate chemical analysis method" is divided into 21 parts.
--- Part 1. Determination of moisture thermal drying method;
--- Part 2. Determination of tin content potassium iodate titration;
--- Part 3. Determination of iron content cerium sulfate titration method;
--- Part 4. Determination of lead content by flame atomic absorption spectrometry and Na2 EDTA titration;
--- Part 5. Determination of arsenic Arsenic antimony molybdenum blue spectrophotometry and iodometric titration;
--- Part 6. Determination of the amount of antimony; malachite green spectrophotometry and flame atomic absorption spectrometry;
--- Part 7. Determination of bismuth content by flame atomic absorption spectrometry;
--- Part 8. Determination of zinc content by flame atomic absorption spectrometry;
--- Part 9. Determination of tungsten oxide content; thiocyanate spectrophotometry;
--- Part 10. Determination of sulfur content High-frequency induction furnace combustion infrared absorption method and potassium iodate titration;
--- Part 11. Determination of the amount of aluminum oxide chromium azure S spectrophotometry;
--- Part 12. Determination of the amount of silica silicon molybdenum blue spectrophotometry and sodium hydroxide titration;
--- Part 13. Determination of magnesia, calcium oxide content; Flame atomic absorption spectrometry;
--- Part 14. Determination of copper content by flame atomic absorption spectrometry;
--- Part 15. Determination of fluorine content ion selective electrode method;
--- Part 16. Determination of silver content; Flame atomic absorption spectrometry;
--- Part 17. Determination of mercury content; atomic fluorescence spectrometry;
--- Part 18. Determination of nickel content by flame atomic absorption spectrometry;
--- Part 19. Determination of cobalt content; Flame atomic absorption spectrometry;
--- Part 20. Determination of cadmium content by flame atomic absorption spectrometry;
--- Part 21. Determination of calcium, magnesium, copper, lead, zinc, arsenic, antimony, bismuth, silver content Inductively coupled plasma atomic emission spectrometry.
This section GB/T 1819 Part 14.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 1819.14-2006 "Determination of copper content of tin concentrate - Determination of copper content flame atomic absorption spectrometry", the Part and GB/T 1819.14-2006 compared to the following major changes.
--- Modify the precision part;
--- Increase the test report terms.
1 Scope
GB/T 1819 provisions of this part of the determination of the amount of copper in tin concentrate.
This section applies to the determination of copper concentrate tin concentrate. Determination of the range of 0.005% ~ 2.00%.
2 Method summary
Samples of hydrochloric acid, nitric acid decomposition, in dilute hydrochloric acid medium, the use of air - acetylene flame atomic absorption spectrometer at a wavelength of 324.7nm, the absorbance of copper is measured.
3 Reagent
Unless otherwise specified, only reagents that are identified as analytically pure and secondary water are used in the analysis.
3.1 Hydrochloric acid (rho = 1.19 g/mL).
3.2 Nitric acid (rho = 1.42 g/mL).
3.3 Hydrochloric acid (1+1).
3.4 Nitric acid (1+1).
3.5 Copper standard storage solution
Weigh 0.5000g copper metal (wCu >= 99.99%) in 250mL beaker, add 20mL nitric acid (3.4), cover the watch glass, low temperature heating until completely dissolved, boil off nitrogen oxides, cooled to room temperature. Into a 500mL volumetric flask, add 10mL nitric acid (3.4), diluted with water to the mark, mix well. 1 mL of this solution contains 1 mg of copper.
3.6 Copper standard solution
Pipette 10.00mL copper standard stock solution (3.5) in 200mL volumetric flask, add 4mL nitric acid (3.4), dilute with water to the mark and mix well. This solution 1mL containing 50µg copper.
4 Instruments
Atomic absorption spectrometer with copper hollow cathode lamp.
In the best working conditions of the instrument, anyone who can meet the following indicators can be used.
--- Characteristic concentration In the solution in accordance with the matrix of the measuring solution, the characteristic concentration of copper should not exceed 0.03µg/mL.
--- Precision. With the highest concentration of standard solution measured 10 times the absorbance, the standard deviation should not exceed 1.0% of the average absorbance; measure the absorbance 10 times with the lowest standard solution (not the "zero" standard solution), and the standard deviation should not exceed the maximum Concentration Standard solution 0.5% of the average absorbance.
--- Work curve linearity. The standard curve is divided into five equal concentrations, the highest segment of the absorbance difference and the lowest segment of the absorbance difference ratio should not be less than 0.70.
5 Sample
Sample size should not be greater than 0.074mm.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 1819.14
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 1819.14-2017 | Methods for chemical analysis of tin concentrates—Part 14: Determination of copper content—Flame atomic absorption spectrometry | current edition | Current |
| GB/T 1819.14-2006 | Methods for chemical analysis of tin concentrates—Part 14: Determination of copper content—Flame atomic absorption spectrometry | previous edition | Superseded |
This page sells the current edition, GB/T 1819.14-2017. Earlier editions are listed for reference only.
How to Download GB/T 1819.14-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1819.1-2022 — Methods for chemical analysis of tin concentrates—Part 1: Determination of moisture content—Heat drying method
GB/T 1819.10-2017 — Methods for chemical analysis of tin concentrates—Part 10: Determination of sulfur content—High frequency combustion with infrared absorption method and potassium iodate titrimetric method
GB/T 1819.11-2017 — Methods for chemical analysis of tin concentrates - Part 11: Determination of aluminium oxide content - Chromazuzal S spectrophotometric method
Secure payment via Stripe
Payments accepted
GB/T 1819.14-2017
$65.00