GB/T 18036-2008The test method of thermo-emf for platinum (English PDF)

铂铑热电偶细丝的热电动势测量方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 18036-2008 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 31, 2008

Implementation date

September 1, 2008

Scope

GB/T 18036-2008 is the English-translated version of 铂铑热电偶细丝的热电动势测量方法.

GB/T 18036-2008 is the Chinese standard "The test method of thermo-emf for platinum". Its scope clause reads: This standard specifies the method for measuring the fuse and comparative law platinum and rhodium thermocouple wire thermal EMF.

This standard applies to the measurement of the diameter of platinum and rhodium thermocouple filaments within 0.05mm ~ 0.1mm range. Other precious metals and base metals heat Thermal EMF measuring galvanic filaments may also be referring to.

At the time of the measurement method using a fuse, measurable thermal emf value platinum and rhodium thermocouple wire diameter of 0.5mm. Other sizes of precious metals Belong to thermocouple wires thermal emf measurements can also be carried out with reference to.

Its clauses include principle of the method; measuring instruments, devices and materials.

Found what you need?

Document preview — GB/T 18036-2008

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 68
Replacing
GB/T 18036-2000

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 PRINCIPLE OF THE METHOD
  • 4 Measuring instruments, devices and materials

1 Scope

This standard specifies the method for measuring the fuse and comparative law platinum and rhodium thermocouple wire thermal EMF.

This standard applies to the measurement of the diameter of platinum and rhodium thermocouple filaments within 0.05mm ~ 0.1mm range. Other precious metals and base metals heat

Thermal EMF measuring galvanic filaments may also be referring to.

At the time of the measurement method using a fuse, measurable thermal emf value platinum and rhodium thermocouple wire diameter of 0.5mm. Other sizes of precious metals

Belong to thermocouple wires thermal emf measurements can also be carried out with reference to.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 8170 numerical rounding rules

JC/T 509 ceramic thermocouple protection tube

JJF1059 Evaluation and Expression of Uncertainty in Measurement

3 PRINCIPLE OF THE METHOD

3.1 Fuse law

According to a pure metal melting temperature constant and thermocouple intermediate metal law, with a small amount of pure gold or palladium measured thermocouple wire wound

On the measurement side, warmed to thermal emf value of the platform, is measured on the thermocouple wires melting occurs, take the average of the readings as the measuring platform result.

3.2 Comparison Method

Thermocouple and standard thermocouple measured bundled together in gold (1064.18 °C) or palladium point (1554.8 °C) temperature than the neighborhood

Comparing, measuring thermal electromotive force value, calculate the results.

4 Measuring instruments, devices and materials

4.1 instruments and equipment

4.1.1 Low potential DC

Accuracy of not less than 0.01 and its corresponding supporting devices, or other equivalent electrically similar accuracy

Measuring equipment.

4.1.2 High temperature furnace

high-temperature furnace and automatic temperature-control system, furnace length of about 500mm or so, the maximum temperature should reach 1600 °C; furnace

The highest temperature area is off-center position should not exceed 20mm, its average temperature zone length should not be less than 10mm, the temperature difference should be within ± 1 °C of.

4.1.3 thermocouple wire annealing apparatus energized

power supply unit should be equipped with an accuracy of not less than 0.5 meter AC current governor and the like.

4.1.4 Thermocouple measuring end welding apparatus (by comparison)

welding thermocouples pollution.

4.1.5 PtRh30-PtRh6 standard thermocouple (comparison method used)

Even with its fuse method in gold (1064.18 °C) and palladium point (1554.8 °C)

Temperature indexing, indexing error should be less than 0.5 °C.

4.2 Material

4.2.1 Fuse

gold, palladium fuse purity of not less than 99.99%, and a diameter of 0.3mm, clean, soft annealed state.

4.2.2 support line

platinum wire, purity of not less than 99.95%, a diameter of 0.4mm ~ 0.5mm, clean.

4.2.3 bundle ligation

platinum wire diameter of 0.15mm, 0.25mm.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 18036

EditionTitleRevisionStatus
GB/T 18036-2008The test method of thermo-emf for platinumcurrent editionCurrent
GB/T 18036-2000The test method of thermo-emf for platinumprevious editionSuperseded

This page sells the current edition, GB/T 18036-2008. Earlier editions are listed for reference only.

How to Download GB/T 18036-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18036-2008

$105.00