Scope
GB/T 17473.5-2008 (Test methods of precious metals pastes used for microelectronics -- Determination of viscosity) is available as an English-translated PDF.
GB/T 17473.5-2008 — This Part specifies the determination method for the viscosity of precious metal pastes, which are used in microelectronics technology. This Part applies to the determination of the viscosity of precious metal pastes, for microelectronics technologies.
Found what you need?
Document preview — GB/T 17473.5-2008
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 68
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative references...5
- 3 Method principle...5
- 4 Instruments and equipment...5
- 5 Specimen...6
- 6 Measurement steps...6
- 7 Description of measurement results...7
- 8 Test report...7
Foreword
This standard is an integrated revision of GB/T 17473-1998 " Test methods of
precious metal pastes used for thick film microelectronics" (all parts). It is
divided into 7 parts:
- GB/T 17473.1-2008 Test methods of precious metals pastes used for
microelectronics - Determination of solids content;
- GB/T 17473.2-2008 Test methods of precious metals pastes used for
microelectronics - Determination of fineness;
- GB/T 17473.3-2008 Test methods of precious metals pastes used for
microelectronics - Determination of sheet resistance;
- GB/T 174743.4-2008 Test methods of precious metals pastes used for
microelectronics - Determination of adhesion;
- GB/T 174743.5-2008 Test methods of pastes used for microelectronics -
Determination of viscosity;
- GB/T 174743.6-2008 Test methods of precious metal pastes used for
microelectronics - Determination of resolution;
- GB/T 174743.7-2008 Test methods of precious metals pastes used for
microelectronics - Determination of solderability and solderleaching
resistance.
This Part is Part 5 of GB/T 17473-2008.
This part replaces GB/T 17473.5-1998 "Test methods of precious metal pastes
used for thick film microelectronics - Determination of viscosity".
Compared with GB/T 17473.5-1998, this Part mainly has the following changes:
- CHANGE the original standard name into "Test methods of precious metals
pastes used for microelectronics - Determination of viscosity";
- In the Scope of the original standard, DELETE the content that "the
determination of viscosity of non-precious metal pastes can also be
implemented with reference to this standard";
- ADD the determination by the use of cone/plate viscometer, which is
suitable for use when there are few samples.
This Part was proposed by China Nonferrous Metals Industry Association.
Test methods of precious metals pastes used for
microelectronics - Determination of viscosity
1 Scope
This Part specifies the determination method for the viscosity of precious metal
pastes, which are used in microelectronics technology.
This Part applies to the determination of the viscosity of precious metal pastes,
for microelectronics technologies.
2 Normative references
The provisions in following documents become the provisions of this Part
through reference in this Part. For the dated references, the subsequent
amendments (excluding corrections) or revisions do not apply to this Part;
however, parties who reach an agreement based on this Part are encouraged
to study if the latest versions of these documents are applicable. For undated
references, the latest edition of the referenced document applies.
GB/T 8170 Rules of rounding off for numerical values & expression and
judgement of limiting values
3 Method principle
The test shaft of the rotary viscometer rotates in a constant temperature paste,
at a certain speed. The viscosity of the paste is determined by measuring the
torque, which is caused by the viscous resistance. When there are few samples,
a cone/plate viscometer is used to measure the torque and shear stress, which
is caused by the viscous resistance of the paste, at a constant temperature, to
determine the viscosity of the paste.
4 Instruments and equipment
4.1 Rotatory viscometer: The measurement error is within ±2%.
4.2 Cone/plate viscometer: The measurement error is within ±2%.
4.3 Thermometer: The division value is 0.1 °C.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download GB/T 17473.5-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 17473.1-2008 — Test methods of precious metals pastes used for microelectronics -- Determination of solids content
GB/T 17473.2-2008 — Test methods of precious metals pastes used for microelectronics -- Determination of fineness
Secure payment via Stripe
Payments accepted
GB/T 17473.5-2008
$75.00