GB/T 15456-2019Determination of the chemical oxygen demand in industrial circulating cooling water - Permanganate index method (English PDF)
Also coversGBT15456-2019
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB/T 15456-2019 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
August 30, 2019
Implementation date
July 1, 2020
Scope
GB/T 15456-2019 (Determination of the chemical oxygen demand in industrial circulating cooling water - Permanganate index method) is available as an English-translated PDF.
GB/T 15456-2019 — This standard specifies the method for determining chemical oxygen demand (COD) using the permanganate index method in industrial circulating cooling water. This standard applies to industrial circulating cooling water chemical oxygen demand (CODMn) content of 0.5mg/L ~ 10mg/L (in O2) Determination. Among them, the volumetric method is applicable to the determination of CODMn of 2mg/L~10mg/L (in O2); potentiometric titration is applicable to CODMn It is a measurement of 0.5 mg/L to 10 mg/L (in terms of O2). When the concentration exceeds the upper limit of the range, it can be diluted and measured. This standard also applies to the determination of chemical oxygen demand (CODMn) in raw water, boiler water and reclaimed water.
Found what you need?
Document preview — GB/T 15456-2019
National Standard of the People's Republic of China
- ICS
- 71.040.40
- Classification
- G 76
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 volume method
- 3.1 Method summary
- 3.2 Reagents or materials
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 15456-2008 "Determination of Chemical Oxygen Demand (COD) in Industrial Circulating Cooling Water by Potassium Permanganate Method,"
Compared with GB/T 15456-2008, the main technical changes except editorial changes are as follows.
--- Revised the scope of application of the standard (see Chapter 1, Chapter 1 of the.2008 edition);
--- Revised the expression of the method summary (see 3.1, Chapter 3 of the.2008 edition);
--- Replace the silver sulfate saturated solution with silver nitrate solution and modify the test procedure (see Chapter 3.3 of the.2008 edition);
--- Increased potentiometric titration (see Chapter 4).
This standard is prepared using the redrafting method with reference to ISO 8467.1993 "Determination of water quality permanganate index", and ISO 8467.1993
The degree of consistency is non-equivalent.
This standard was proposed by the China Petroleum and Chemical Industry Federation.
This standard is under the jurisdiction of the National Chemical Standardization Technical Committee (SAC/TC63).
This standard was drafted. Jiyuan Qingyuan Water Treatment Co., Ltd., Jiangsu Special Equipment Safety Supervision and Inspection Institute Changzhou Branch, Guang
State Special Pressure Equipment Testing and Research Institute, Shenzhen Junnuo Testing Co., Ltd., Xiamen Huajian Testing Technology Co., Ltd., CNOOC Tianjin Chemical
Research and Design Institute Co., Ltd., Metrohm China Ltd., Shanghai Light Industry Research Institute Co., Ltd., Guangdong Petroleum and Fine Chemical Research
Research Institute, METTLER TOLEDO Instrument (Shanghai) Co., Ltd., Zhejiang Shuizhiyin Environmental Protection Technology Co., Ltd.
1 Scope
This standard specifies the method for determining chemical oxygen demand (COD) using the permanganate index method in industrial circulating cooling water.
This standard applies to industrial circulating cooling water chemical oxygen demand (CODMn) content of 0.5mg/L ~ 10mg/L (in O2)
Determination. Among them, the volumetric method is applicable to the determination of CODMn of 2mg/L~10mg/L (in O2); potentiometric titration is applicable to CODMn
It is a measurement of 0.5 mg/L to 10 mg/L (in terms of O2). When the concentration exceeds the upper limit of the range, it can be diluted and measured.
This standard also applies to the determination of chemical oxygen demand (CODMn) in raw water, boiler water and reclaimed water.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
Preparation of GB/T 601 chemical reagent standard titration solution
Preparation of preparations and products used in GB/T 603 chemical reagent test method
GB/T 6682 Analytical laboratory water specifications and test methods
3 volume method
3.1 Method summary
After the water sample is acidified, accurately add a known amount of potassium permanganate standard solution, heat it to fully oxidize, and add excess oxalic acid.
The sodium standard solution is used to reduce the remaining potassium permanganate, and then the potassium permanganate standard titration solution is used to drop excess sodium oxalate until the redox reaction
At the end point, the amount of potassium permanganate consumed is converted into the mass concentration of oxygen consumed.
MnO4- 8H 5e= Mn2 4H2O
3.2 Reagents or materials
Caution - The strong acid used in this standard is corrosive and should be avoided when inhaled or in contact with the skin. Splash on the body should be used immediately
Rinse with water, seek medical attention if it is serious.
3.2.1 Reagents and water used in this standard, unless otherwise specified, should be used with analytically pure reagents and in accordance with GB/T 6682 Class III water.
3.2.2 Standard titration solutions, preparations and products used in the test shall be in accordance with GB/T 601 and GB/T 603 when no other requirements are specified.
Provision is made.
3.2.3 Sulfuric acid solution. 1 3.
3.2.4 Silver nitrate solution..200g/L, stored in a brown bottle.
3.2.5 sodium oxalate standard solution. c (1/2Na2C2O4) about 0.01mol/L, the use concentration should be greater than the potassium permanganate standard titration solution.
3.2.6 Potassium permanganate standard titration solution. c (1/5KMnO4) about 0.01mol/L.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB/T 31329-2025Technical specification for water saving in circulating cooling water systems
- GB/T 44111-2024Code of maintenance test for electrochemical energy storage station
- GB/T 44325-2024Technical specification for zero discharge of industrial circulating cooling water
- HG/T 4331-2012Water treatment chemicals - Evaluation method for coagulation performance
- HG/T 3923-2007Water quality standard for reclaimed water used in circulating cooling water
How to Download GB/T 15456-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 601-2016 — Chemical Reagent - Preparations of Standard Volumetric Solutions
GB/T 6011-2005 — Test method for flammability characteristics of fiber-reinforced plastics-Incandescent rod method
GB/T 6011-2026 — Test method for the flammability characteristics of fibre reinforced plastics - Incandescent rod method
Secure payment via Stripe
Payments accepted
GB/T 15456-2019
$80.00