GB/T 14849.3-2020Methods for chemical analysis of silicon metal—Part 3: Determination of calcium content (English PDF)
工业硅化学分析方法 第3部分:钙含量的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 14849.3-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 6, 2020
Implementation date
February 1, 2021
Scope
GB/T 14849.3-2020 is the English-translated version of 工业硅化学分析方法 第3部分:钙含量的测定.
GB/T 14849.3-2020 is the part of the Chinese series on the chemical analysis of silicon metal that determines the calcium content. It gives two methods, flame atomic absorption spectrometry and chlorophosphonazo I spectrophotometry, with the quality assurance and control and the test report.
It applies to silicon metal with a calcium content from 0.0050 % to 0.55 %. Silicon producers, traders and the aluminium and silicone industries that buy it use it.
Issued on 6 March 2020, it has applied since 1 February 2021, replacing GB/T 14849.3-2007.
Found what you need?
Document preview — GB/T 14849.3-2020
National Standard of the People's Republic of China
- ICS
- 77.040.30
- Classification
- H 17
- Replacing
- GB/T 14849.3-2007
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 Flame atomic absorption spectrometry5
- 4 Chlorophosphonazo I spectrophotometry9
- 5 Quality assurance and control13
- 6 Test report13
Foreword
GB/T 14849 "Methods for chemical analysis of industrial silicon" consists of the following 11 parts.
- Part 1: Determination of iron content;
- Part 2: Determination of aluminum content - Chrome azurol S spectrophotometric method;
- Part 3: Determination of calcium content;
- Part 4: Determination of elements content Inductively coupled plasma atomic emission spectrometric method;
- Part 5: Determination of elements content - Analysis using an X-ray fluorescence method;
- Part 6: Determination of carbon-Infrared absorption method;
- Part 7: Determination of phosphorus content - Phosphorus molybdenum blue spectrophotometry;
- Part 8: Determination of copper content - Atomic absorption spectrometric method;
- Part 9: Determination of titanium content - Diantipyryl methane spectrophotometry;
- Part 10: Determination of mercury content - Atomic fluorescence spectrometric method;
- Part 11: Determination of chromium content - Diphenylcarbazide spectrophotometric method.
This Part is Part 3 of GB/T 14849.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 14849.3-2007 "Methods for chemical analysis of silicon metal - Part 3: Determination of calcium content". Compared with GB/T 14849.3-2007, in addition to editorial modifications, the main technical changes are as follows.
- added warning;
- modified range of determination from 0.020%~0.30% to 0.0050%~0.55% (see Clause 1 of this Edition, Clause 1 of Edition 2007);
- added normative references (see Clause 2 of this Edition);
- modified method summary (see 3.1 and 4.1 of this Edition, Clause 2 and Clause 11 of Edition 2007);
- added requirements for analysis reagents and water (see 3.2 and 4.2 of this Edition);
- modified precision (see 3.7 and 4.7 of this Edition, Clause 8 and Clause 17 of Edition 2007);
- added test report (see Clause 6 of this Edition).
1 Scope
This Part of GB/T 14849 specifies the method for determination of calcium content in silicon metal.
This Part is applicable to determination of calcium content in silicon metal. The range for determination is. 0.0050%~0.55%.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 8170, Rules of rounding off for numerical values & expression and judgement of limiting values
3 Flame atomic absorption spectrometry
3.1 Method summary
Use hydrofluoric acid and nitric acid to dissolve test material. Perchloric acid smokes to remove silicon and fluorine. Use nitric acid to dissolve the residue.
Use lanthanum salt to suppress aluminum interference. At a wavelength of 422.7nm of flame atomic absorption spectrometer, use air-acetylene flame to measure the absorbance of calcium. Calculate the mass fraction of calcium.
3.2 Reagents and materials
Unless otherwise specified, in the analysis, it shall only use the confirmed analytically-pure reagent AND distilled water or deionized water or equivalent-pure water.
3.2.1 Perchloric acid (rho=1.67g/L).
3.2.7 Calcium standard solution
Pipette 25.00mL of calcium standard stock solution (3.2.6) in a 250mL volumetric flask. Use water to dilute to the scale. Mix well. 1mL of this solution contains 50µg of calcium.
3.3 Instruments
3.3.2 Platinum dish, 100mL.
3.3.3 Teflon beaker, 250mL.
3.3.1 Atomic absorption spectrometer, attached with calcium hollow cathode lamp
Under the best working conditions of the instrument, any atomic absorption spectrometer that can achieve the following indicators can be used.
3.4 Specimen
The specimen shall be able to pass through a 0.149mm standard sieve. Use magnet to remove iron.
3.5 Test steps
3.5.1 Test material
Weigh 0.50g of specimen (3.4), to the nearest of 0.0001g.
3.5.2 Number of determinations
Do two tests in parallel.
3.5.3 Blank test
Conduct blank test with test material (3.5.1).
3.5.4 Determination
3.6 Processing of test data
Calculate the mass fraction of calcium wCa according to formula (1).
3.7 Precision
3.7.1 Repeatability
Obtain the measured value of two independent test results under repeatability conditions. Within the average range given in Table 2, the absolute difference between the two test results does not exceed the repeatability limit (r).
4 Chlorophosphonazo I spectrophotometry
4.1 Method summary
Use hydrofluoric acid and nitric acid to decompose the test material. Perchloric acid smokes to remove silicon and fluorine. Use hydrochloric acid to dissolve the residue. Use triethanolamine, 1,10-phenanthroline, and acetylacetone to mask interference elements. At pH10~pH10.5, calcium and chlorophosphonazo I form a colored complex. Take the faded solution of EGTA-Pb as a reference.
4.2 Reagents and material
Unless otherwise specified, in the analysis, it shall only use the confirmed analytically-pure reagent AND distilled water or deionized water or equivalent-pure water.
4.2.1 Hydrofluoric acid (rho=1.14g/mL).
4.2.2 Nitric acid (1+1).
4.2.3 Perchloric acid (1+1).
4.2.4 Hydrochloric acid (1+1).
4.2.5 Triethanolamine (1+3), stored in polyethylene bottles.
4.2.11 Calcium standard stock solution
Weigh 2.4970g of calcium carbonate that has been dried at 105°C and cooled to room temperature in a dryer (reference reagent, >=99.95%). Place in a beaker. Add about 200mL of water. Then add hydrochloric acid (4.2.4) dropwise to completely dissolve.
4.3 Instruments
4.4 Specimen
The specimen shall be able to pass a 0.149mm standard sieve. Use magnet to remove iron.
4.5 Test steps
4.5.1 Test material
Weigh 1.0g of specimen (4.4), to the nearest of 0.0001g.
4.5.5 Drawing of working curve
4.5.5.1 Pipette 0mL, 0.50mL, 1.00mL, 2.00mL, 3.00mL, 4.00mL, 5.00mL, 6.00mL of calcium standard solution (4.2.12) to respectively place in a set of 50mL volumetric flasks. The following shall be carried out according to 4.5.4.4~4.5.4.5.
5 Quality assurance and control
In analysis, use standard sample or control sample to verify. Or at least use standard sample or control sample to verify the analysis method once every year.
6 Test report
The test report shall give at least the following information. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 14849.3
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 14849.3-2020 | Methods for chemical analysis of silicon metal—Part 3: Determination of calcium content | current edition | Current |
| GB/T 14849.3-2007 | Methods for chemical analysis of silicon metal—Part 3: Determination of calcium content | previous edition | Superseded |
This page sells the current edition, GB/T 14849.3-2020. Earlier editions are listed for reference only.
How to Download GB/T 14849.3-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 14849.1-2020 — Methods for chemical analysis of silicon metal—Part 1: Determination of iron content
GB/T 14849.10-2016 — Methods for chemical analysis of silicon metal - Part 10: Determination of mercury content - Atomic fluorescence spectrometry method
Secure payment via Stripe
Payments accepted
GB/T 14849.3-2020
$135.00