Valid

GB/T 14849.3-2020Methods for chemical analysis of silicon metal—Part 3: Determination of calcium content (English PDF)

工业硅化学分析方法 第3部分:钙含量的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 14849.3-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 6, 2020

Implementation date

February 1, 2021

Scope

GB/T 14849.3-2020 is the English-translated version of 工业硅化学分析方法 第3部分:钙含量的测定.

GB/T 14849.3-2020 is the part of the Chinese series on the chemical analysis of silicon metal that determines the calcium content. It gives two methods, flame atomic absorption spectrometry and chlorophosphonazo I spectrophotometry, with the quality assurance and control and the test report.

It applies to silicon metal with a calcium content from 0.0050 % to 0.55 %. Silicon producers, traders and the aluminium and silicone industries that buy it use it.

Issued on 6 March 2020, it has applied since 1 February 2021, replacing GB/T 14849.3-2007.

Found what you need?

Document preview — GB/T 14849.3-2020

National Standard of the People's Republic of China

ICS
77.040.30
Classification
H 17
Replacing
GB/T 14849.3-2007

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Flame atomic absorption spectrometry5
  • 4 Chlorophosphonazo I spectrophotometry9
  • 5 Quality assurance and control13
  • 6 Test report13

Foreword

GB/T 14849 "Methods for chemical analysis of industrial silicon" consists of the following 11 parts.

- Part 1: Determination of iron content;

- Part 2: Determination of aluminum content - Chrome azurol S spectrophotometric method;

- Part 3: Determination of calcium content;

- Part 4: Determination of elements content Inductively coupled plasma atomic emission spectrometric method;

- Part 5: Determination of elements content - Analysis using an X-ray fluorescence method;

- Part 6: Determination of carbon-Infrared absorption method;

- Part 7: Determination of phosphorus content - Phosphorus molybdenum blue spectrophotometry;

- Part 8: Determination of copper content - Atomic absorption spectrometric method;

- Part 9: Determination of titanium content - Diantipyryl methane spectrophotometry;

- Part 10: Determination of mercury content - Atomic fluorescence spectrometric method;

- Part 11: Determination of chromium content - Diphenylcarbazide spectrophotometric method.

This Part is Part 3 of GB/T 14849.

This Part was drafted in accordance with the rules given in GB/T 1.1-2009.

This Part replaces GB/T 14849.3-2007 "Methods for chemical analysis of silicon metal - Part 3: Determination of calcium content". Compared with GB/T 14849.3-2007, in addition to editorial modifications, the main technical changes are as follows.

- added warning;

- modified range of determination from 0.020%~0.30% to 0.0050%~0.55% (see Clause 1 of this Edition, Clause 1 of Edition 2007);

- added normative references (see Clause 2 of this Edition);

- modified method summary (see 3.1 and 4.1 of this Edition, Clause 2 and Clause 11 of Edition 2007);

- added requirements for analysis reagents and water (see 3.2 and 4.2 of this Edition);

- modified precision (see 3.7 and 4.7 of this Edition, Clause 8 and Clause 17 of Edition 2007);

- added test report (see Clause 6 of this Edition).

1 Scope

This Part of GB/T 14849 specifies the method for determination of calcium content in silicon metal.

This Part is applicable to determination of calcium content in silicon metal. The range for determination is. 0.0050%~0.55%.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 8170, Rules of rounding off for numerical values & expression and judgement of limiting values

3 Flame atomic absorption spectrometry

3.1 Method summary

Use hydrofluoric acid and nitric acid to dissolve test material. Perchloric acid smokes to remove silicon and fluorine. Use nitric acid to dissolve the residue.

Use lanthanum salt to suppress aluminum interference. At a wavelength of 422.7nm of flame atomic absorption spectrometer, use air-acetylene flame to measure the absorbance of calcium. Calculate the mass fraction of calcium.

3.2 Reagents and materials

Unless otherwise specified, in the analysis, it shall only use the confirmed analytically-pure reagent AND distilled water or deionized water or equivalent-pure water.

3.2.1 Perchloric acid (rho=1.67g/L).

3.2.7 Calcium standard solution

Pipette 25.00mL of calcium standard stock solution (3.2.6) in a 250mL volumetric flask. Use water to dilute to the scale. Mix well. 1mL of this solution contains 50µg of calcium.

3.3 Instruments

3.3.2 Platinum dish, 100mL.

3.3.3 Teflon beaker, 250mL.

3.3.1 Atomic absorption spectrometer, attached with calcium hollow cathode lamp

Under the best working conditions of the instrument, any atomic absorption spectrometer that can achieve the following indicators can be used.

3.4 Specimen

The specimen shall be able to pass through a 0.149mm standard sieve. Use magnet to remove iron.

3.5 Test steps

3.5.1 Test material

Weigh 0.50g of specimen (3.4), to the nearest of 0.0001g.

3.5.2 Number of determinations

Do two tests in parallel.

3.5.3 Blank test

Conduct blank test with test material (3.5.1).

3.5.4 Determination

3.6 Processing of test data

Calculate the mass fraction of calcium wCa according to formula (1).

3.7 Precision

3.7.1 Repeatability

Obtain the measured value of two independent test results under repeatability conditions. Within the average range given in Table 2, the absolute difference between the two test results does not exceed the repeatability limit (r).

4 Chlorophosphonazo I spectrophotometry

4.1 Method summary

Use hydrofluoric acid and nitric acid to decompose the test material. Perchloric acid smokes to remove silicon and fluorine. Use hydrochloric acid to dissolve the residue. Use triethanolamine, 1,10-phenanthroline, and acetylacetone to mask interference elements. At pH10~pH10.5, calcium and chlorophosphonazo I form a colored complex. Take the faded solution of EGTA-Pb as a reference.

4.2 Reagents and material

Unless otherwise specified, in the analysis, it shall only use the confirmed analytically-pure reagent AND distilled water or deionized water or equivalent-pure water.

4.2.1 Hydrofluoric acid (rho=1.14g/mL).

4.2.2 Nitric acid (1+1).

4.2.3 Perchloric acid (1+1).

4.2.4 Hydrochloric acid (1+1).

4.2.5 Triethanolamine (1+3), stored in polyethylene bottles.

4.2.11 Calcium standard stock solution

Weigh 2.4970g of calcium carbonate that has been dried at 105°C and cooled to room temperature in a dryer (reference reagent, >=99.95%). Place in a beaker. Add about 200mL of water. Then add hydrochloric acid (4.2.4) dropwise to completely dissolve.

4.3 Instruments

4.4 Specimen

The specimen shall be able to pass a 0.149mm standard sieve. Use magnet to remove iron.

4.5 Test steps

4.5.1 Test material

Weigh 1.0g of specimen (4.4), to the nearest of 0.0001g.

4.5.5 Drawing of working curve

4.5.5.1 Pipette 0mL, 0.50mL, 1.00mL, 2.00mL, 3.00mL, 4.00mL, 5.00mL, 6.00mL of calcium standard solution (4.2.12) to respectively place in a set of 50mL volumetric flasks. The following shall be carried out according to 4.5.4.4~4.5.4.5.

5 Quality assurance and control

In analysis, use standard sample or control sample to verify. Or at least use standard sample or control sample to verify the analysis method once every year.

6 Test report

The test report shall give at least the following information. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 14849.3

EditionTitleRevisionStatus
GB/T 14849.3-2020Methods for chemical analysis of silicon metal—Part 3: Determination of calcium contentcurrent editionCurrent
GB/T 14849.3-2007Methods for chemical analysis of silicon metal—Part 3: Determination of calcium contentprevious editionSuperseded

This page sells the current edition, GB/T 14849.3-2020. Earlier editions are listed for reference only.

How to Download GB/T 14849.3-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 14849.3-2020

$135.00