GB/T 14849.1-2020Methods for chemical analysis of silicon metal—Part 1: Determination of iron content (English PDF)
工业硅化学分析方法 第1部分:铁含量的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 14849.1-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 6, 2020
Implementation date
February 1, 2021
Scope
GB/T 14849.1-2020 is the English-translated version of 工业硅化学分析方法 第1部分:铁含量的测定.
GB/T 14849.1-2020 is the part of the Chinese series on the chemical analysis of silicon metal that determines the iron content.
It gives two methods, 1,10-phenanthroline spectrophotometry and flame atomic absorption spectrometry, each with the reagents, the apparatus, the procedure and the calculation, and the quality assurance and control and test report that go with it.
It applies to silicon metal with an iron content from 0.050 % to 0.75 %. Silicon producers, traders and the aluminium and silicone industries that buy it use it.
Issued on 6 March 2020, it has applied since 1 February 2021, replacing GB/T 14849.1-2007.
Found what you need?
Document preview — GB/T 14849.1-2020
National Standard of the People's Republic of China
- ICS
- 77.040.30
- Classification
- H 17
- Replacing
- GB/T 14849.1-2007
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 1,10-phenanthroline spectrophotometry5
- 4 Flame atomic absorption spectrometry9
- 5 Quality assurance and control13
- 6 Test report13
Foreword
GB/T 14849 "Methods for chemical analysis of industrial silicon" consists of the following 11 parts:
- Part 1: Determination of iron content;
- Part 2: Determination of aluminum content - Chrome azurol S spectrophotometric method;
- Part 3: Determination of calcium content;
- Part 4: Determination of elements content Inductively coupled plasma atomic emission spectrometric method;
- Part 5: Determination of elements content - Analysis using an X-ray fluorescence method;
- Part 6: Determination of carbon-Infrared absorption method;
- Part 7: Determination of phosphorus content - Phosphorus molybdenum blue spectrophotometry;
- Part 8: Determination of copper content - Atomic absorption spectrometric method;
- Part 9: Determination of titanium content - Diantipyryl methane spectrophotometry;
- Part 10: Determination of mercury content - Atomic fluorescence spectrometric method;
- Part 11: Determination of chromium content - Diphenylcarbazide spectrophotometric method.
This Part is Part 1 of GB/T 14849.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 14849.1-2007 "Methods for chemical analysis of silicon metal - Part 1: Determination of iron content - 1,10-Phenanthrolion spectrophotometric method". Compared with GB/T 14849.1-2007, in addition to editorial modifications, the main technical changes are as follows:
- added warning;
- modified range of determination from 0.10%~0.65% to 0.050%~0.75% (see […]
1 Scope
This Part of GB/T 14849 specifies the method for determination of iron content in silicon metal.
This Part is applicable to determination of iron content in silicon metal. The range for determination is: 0.050%~0.75%.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 8170, Rules of rounding off for numerical values & expression and judgement of limiting values
3 1,10-phenanthroline spectrophotometry
3.1 Method summary
Use hydrofluoric acid and nitric acid to dissolve the specimen. Add perchloric acid to evaporate till smoke appears to remove silicon and fluorine. Use hydrochloric acid to dissolve the residue. Use hydroxylamine hydrochloride to reduce Fe(III) to Fe(II). In pH3~pH5 sodium acetate buffer medium, Fe(II) ion and 1,10-phenanthroline form a red complex. At 510nm wavelength, measure the absorbance of the solution. Calculate the mass fraction of iron.
3.2 Reagents and materials
Unless otherwise specified, in the analysis, it shall only use the confirmed analytically-pure reagent AND distilled water or deionized water or equivalent-pure water.
3.2.1 Hydrofluoric acid (rho=1.14g/mL).
3.2.2 Perchloric acid (rho=1.67g/mL).
3.2.3 Nitric acid (1+1).
3.2.4 Hydrochloric acid (1+1).
3.2.5 Hydroxylamine hydrochloride solution (10g/L): Weigh 2.0g of hydroxylamine hydrochloride. Place in a 100mL beaker. Add a small amount of water and stir to dissolve completely. Use water to dilute to 200mL. Mix well.
3.2.6 1,10-phenanthroline solution (5g/L): Weigh 2.5g of 1,10-phenanthroline. Place in a 100mL beaker. Add 2mL of hydrochloric acid (3.2.4), 20mL of water. Stir and dissolve completely. Use water to dilute to 500mL. Mix well.
3.2.7 Acetic acid-sodium acetate buffer solution: Weigh 272g of sodium acetate trihydrate. Place in a 1L beaker. Add 500mL of water. Stir and dissolve completely. Filter in a 1000mL volumetric flask. Add 240mL of glacial acetic acid (rho=1.05g/mL). Use water to dilute to the scale. Mix well.
3.2.8 Mixed color developing solution: Mix hydroxylamine hydrochloride solution (3.2.5), 1,10-phenanthroline solution (3.2.6) and acetic acid-sodium acetate buffer solution (3.2.7) according to the volume of (1+1+2). Use within one week.
3.2.9 Iron standard stock solution: Weigh 0.2860g of ferric oxide that has been burned at 600°C for 1h and placed in a dryer to cool to room temperature (benchmark reagent, >=99.995%). Place in a beaker. Add 30mL of hydrochloric acid (3.2.4). Heat at a low temperature to dissolve. Cool to room temperature. Transfer to a 1000mL volumetric flask. Use water to dilute to the scale. Mix well. 1mL of this solution contains 200µg of iron.
3.2.10 Iron standard solution: Pipette 25.00mL of iron standard stock solution (3.2.9) into a 100mL volumetric flask. Use water to dilute to the scale. Mix well. 1mL of this solution contains 50µg of iron.
3.3 Instruments
3.3.1 Spectrophotometer.
3.3.2 Teflon beaker, 250mL.
3.5.5 Drawing of working curve
3.5.5.1 Pipette 0mL, 1.00mL, 2.00mL, 4.00mL, 6.00mL, 8.00mL, 10.00mL of iron standard solution (3.2.10). Respectively put them in a set of 100mL volumetric flasks. Add 2.5mL of hydrochloric acid (3.2.4). Use water to dilute to about 50mL. Add 5mL of mixed color developing solution (3.2.8). Use water to dilute to the scale. Mix well. Leave it for 15min.
3.5.5.2 Transfer part of the color developing solution (3.5.5.1) into the cuvette (3.3.4). Take reagent blank solution as reference. At a wavelength of 510nm, measure its absorbance. Use the mass of iron as the abscissa and absorbance as the ordinate to draw the working curve.
3.6 Processing of test data
Calculate the iron mass fraction wFe according to formula (1):
Where,
m1 - Iron mass of test material solution checked from the working curve, in micrograms (µg);
R1 - Dilution factor;
m0 - Mass of test material, in grams (g).
Two significant digits are reserved for test results. Numerical rounding shall be implemented in accordance with GB/T 8170.
3.7 Precision
4 Flame atomic absorption spectrometry
4.5.2 Number of determinations
Do two tests in parallel.
4.5.3 Blank test
Conduct blank test with test material.
4.5.4 Determination
4.5.4.1 Place the test material (4.5.1) in a 250mL PTFE beaker (4.3.2) or platinum dish (4.3.3). Use a little water to moisten. Add 5mL of hydrofluoric acid (4.2.1) in portions. Decompose at room temperature for 3min. Add 10mL of nitric acid (4.2.3) in drops. Cover the lid. Heat at a low temperature to dissolve the sample until the sample is completely dissolved. Rinse the lid and wall. Add 5mL of perchloric acid (4.2.2). Continue heating till smoke appears. Steam to nearly dry. Remove. Add about 10mL of water. Heat to dissolve the salt. Cool to room temperature.
4.5.4.2 According to the mass fraction of iron in the test material, respectively process according to the following methods:
- When the mass fraction of iron is 0.050%~0.15%, transfer the test solution (4.5.4.1) into a 100mL volumetric flask. Add 10mL of hydrochloric acid (4.2.4). Use water to dilute to the scale. Mix well. The test solution volume (V) is 100mL.
- When the mass fraction of iron is >0.15%~0.25%, transfer the test solution (4.5.4.1) into a 200mL volumetric flask. Add 20mL of hydrochloric acid (4.2.4). Use water to dilute to the scale. Mix well. The test solution volume (V) is 200 mL.
- When the mass fraction of iron is >0.25%~0.75%, transfer the test solution (4.5.4.1) into a 500mL volumetric flask. Add 50mL of hydrochloric acid (4.2.4). Use water to dilute to the scale. Mix well. The test solution volume (V) is 500 mL.
4.5.4.3 Put test solution (4.5.4.2) at a wavelength of 248.3nm. Use Air-acetylene flame, and use test material blank solution to adjust zero. Measure the absorbance of iron. Find the iron mass concentration (rho) from the working curve.
4.5.5 Drawing of working curve
4.5.5.1 Pipette 0mL, 1.00mL, 2.00mL, 4.00mL, 6.00mL, 8.00mL, 10.00mL of iron standard solution (4.2.6). Respectively put them in a set of 100mL volumetric flasks. Add 10mL of hydrochloric acid (4.2.4). Use water to dilute to […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 14849.1
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 14849.1-2020 | Methods for chemical analysis of silicon metal—Part 1: Determination of iron content | current edition | Current |
| GB/T 14849.1-2007 | Methods for chemical analysis of silicon metal—Part 1: Determination of iron content | previous edition | Superseded |
This page sells the current edition, GB/T 14849.1-2020. Earlier editions are listed for reference only.
How to Download GB/T 14849.1-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
GB/T 14849.10-2016 — Methods for chemical analysis of silicon metal - Part 10: Determination of mercury content - Atomic fluorescence spectrometry method
GB/T 14849.11-2016 — Methods for chemical analysis of silicon metal - Part 11: Determination of chromium content - 1,5-Diphenylcarbohydrazide spectrophotometric method
Secure payment via Stripe