GB/T 13161-2015Radiation protection instrumentation -- Measurement of personal dose equivalents Hp (10) and Hp (0.07) for X, gamma, neutron and beta radiations -- Direct reading personal dose equivalent meters (English PDF)
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for GB/T 13161-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
October 9, 2015
Implementation date
May 1, 2016
Scope
GB/T 13161-2015 (Radiation protection instrumentation -- Measurement of personal dose equivalents Hp (10) and Hp (0.07) for X, gamma, neutron and beta radiations -- Direct reading personal dose equivalent meters) is available as an English-translated PDF.
GB/T 13161-2015 — This standard applies to personal dose equivalents with the following characteristics. a) worn on the human torso or limbs; b) measuring individual dose equivalents Hp(10) and Hp(0.07) produced by external X and gamma, neutron and beta radiation, and measuring individual agents Volume equivalent rate H p(10) and H p(0.07); c) has a digital display; d) may have a personal dose equivalent or personal dose equivalent rate alarm function.
Therefore, this standard applies to the following dose levels (including the respective dose rate) and the measurement of the radiation combination.
1) Hp(10) and Hp(0.07) produced by X and gamma radiation; 2) Hp(10) and Hp(0.07) produced by X, gamma and beta radiation; 3) Hp(10) produced by X and gamma radiation; 4) Hp(10) generated by neutron radiation; 5) Hp(10) produced by X, gamma and neutron radiation; 6) Hp (0.07) produced by X, gamma and beta radiation.
Note 1. Unless otherwise stated, when referring to "dose" in this standard, it refers to the individual dose equivalent. Note 2. Unless otherwise stated, when reference is made to "dose meter" in this standard, it is meant to include all personal dose equivalents.
This standard specifies the requirements for dosimeters and their associated readout systems (if provided). This standard specifies the general characteristics, general test methods, radiation characteristics, and electrical, mechanical, safety, and environmental characteristics of the above dosimeters.
Only the relevant readout system is required to affect the personal dose equivalent readout accuracy and alarm settings and to the reader to the dose meter Resounding requirements.
This standard also specifies the classification of instruments used in Appendix C based on different measurement capabilities. This standard does not include special requirements for accident or emergency dosimetry, although dosimeters can be used for this purpose.
This standard does not apply to testing Dosimeters that measure pulsed radiation (eg, radiation produced by most medical X-ray diagnostic equipment, linear accelerators, or similar devices).
Found what you need?
Document preview — GB/T 13161-2015
National Standard of the People's Republic of China
- ICS
- 13.280
- Classification
- F 84
- Replacing
- GB/T 13161-2003; GB/T 14323-1993
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 13161-2003 "Direct reading personal X and gamma radiation dose equivalent and dose equivalent rate monitor" and GB/T 14323-1993 "X, gamma radiation personal alarm device", compared with GB/T 13161-2003 and GB/T 14323-1993 main technology the changes are as follows.
--- Integrate different instrument standards for different types of radiation (X, gamma, neutron and beta radiation) into one standard, extending the standard Range of use;
--- Electromagnetic compatibility performance requirements and tests increase RF electromagnetic fields, conducted disturbances caused by fast transients or bursts, induced by surges Conducted disturbances, conducted disturbances caused by radio frequency, 50 Hz magnetic field, voltage sag and short interruptions;
--- Mechanical performance requirements and tests have increased the flutter test;
--- Added "uncertainty" content;
--- Removed "storage, transportation, packaging, signs".
This standard uses the translation method equivalent to the use of IEC 61526:2010 "radiation protection equipment to measure X, gamma, neutron and beta radiation personal dose when Volume Hp (10) and Hp (0.07) Direct Reading Personal Dose Equivalent Apparatus.
The documents of our country that have a consistent correspondence with the international documents referenced in this standard are as follows.
--- GB/T 8897.1-2008 Primary batteries Part 1. General (IEC 60086-1:2007, MOD)
--- GB/T 8897.2-2008 Primary batteries Part 2. Dimensions and electrical performance requirements (IEC 60086-2:2007, MOD)
---GB/T 17626.2-2006 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test (IEC 61000-4-2.
2001, IDT)
---GB/T 17626.3-2006 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test (IEC 61000-4-3:2002, IDT)
---GB/T 17626.6-2008 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction (IEC 61000-4-6:2006, IDT)
---GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test (IEC 61000-4-8.
2001, IDT)
---GB/T 17799.2-2003 Electromagnetic compatibility general standard immunity test in industrial environment (IEC 61000-6-2.
1999, IDT)
This standard has made the following editorial changes.
--- Replace IEC 60529:2001 with IEC 60529:2001 and its Amendment1 in "2 Normative References" (1999), and the international standards of the corresponding national standards have been changed to the standards of China;
--- Because the X, gamma personal dose equivalent instrument can also use other ISO phantoms during the test, will be in 7.5, 9.3.5, 9.4.1.2 and 9.4.2.2 the "ISO water slab phantom" was changed to "ISO phantom";
--- Change the "ISO 6980 series standard" in 9.6.2.2 to "GB/T 12164.1-2008, ISO 6980-2:2004 and ISO 6980-3:2006";
--- 9.9.2.2 in the third line "in the case of step increase or decrease the dose equivalent rate of irradiation" changed to "in step increase dose equivalent in the case of rate irradiation", line 6 "in the case of increasing or decreasing the dose equivalent rate of irradiation" is changed to "in stepping reducer" in the case of the irradiation of the equivalent amount rate, the original text is incorrect;
--- Replace 9.9.4.1 "(see Table 4~3 of the sixth line)" with "(see item 10, table 5 and item 8 of Table 6)" and Add "9.9.4" to the "Article Number" in item 10 of Table 4 and Item 8 of Table 5 and Table 6;
---11.7 Delete "60Hz" that does not meet the national conditions;
--- 11.2 in the 11th column description, see "9.4.2" was changed to "see 9.3.2", the original text is incorrect;
--- The third line of the first column of Table 3 "dose rate. Hp (10), Hp (0.07)" is incorrect, changed to "dose rate. H p(10), H p(0.07)";
--- In the fourth column of the fifth row of Table 4 (No. 4), "EIntroduction this standard applies to active and direct reading personal dose equivalent measuring instruments and monitors. The instrument is used to measure X, gamma, neutron and beta radiation.
The individual doses are equivalent to Hp (10) and Hp (0.07).
For personal dose equivalent Hp (10) or personal dose equivalent rate H p(10) and X and gamma radiation give the two minimums of photon energy Rated range. The first rated range is 20keV~150keV for workplaces using low energy X-rays (eg medical diagnosis), Two rated ranges from 80 keV to 1.5 MeV are used in workplaces where high energy X-rays and/or gamma sources are used (eg industrial). For neutrons Radiation, the minimum rated range of neutron energy is 0.025 eV (thermal neutron) ~ 5 MeV. The rated range can be extended to different radiation field related targets all energy that is covered.
For individual dose equivalents Hp (0.07) and X and gamma radiation, the minimum rated range of photon energy is 20 keV to 150 keV, for beta radiation, the minimum rating range is 0.2 MeV to 0.8 MeV. The rated range can be extended to cover different radiation field related standards Have energy.
Examples of extended nominal ranges are given in Appendix C.
In some applications (eg 6 MaiV photon radiation in the vicinity of a nuclear reactor), it is desirable to measure photon energy up to 10 MeV Personal dose equivalent (rate) Hp (10). In some other applications, it is desirable to measure Hp(10) down to 10 keV.
For personal dose equivalents, it is required to measure the dose values Hp(10) and Hp(0.07) and give the dose rate value H for monitoring.
p(10) and
p (0.07). Measurement of these dose rate values is an option for personal dose equivalents.
Radiation protection instruments measure X, gamma, neutron and Beta radiation personal dose equivalents Hp (10) and Hp (0.07) Direct reading personal dose equivalent
1 Scope
This standard applies to personal dose equivalents with the following characteristics.
a) worn on the human torso or limbs;
b) measuring individual dose equivalents Hp(10) and Hp(0.07) produced by external X and gamma, neutron and beta radiation, and measuring individual agents Volume equivalent rate H p(10) and H p(0.07);
c) has a digital display;
d) may have a personal dose equivalent or personal dose equivalent rate alarm function.
Therefore, this standard applies to the following dose levels (including the respective dose rate) and the measurement of the radiation combination.
1) Hp(10) and Hp(0.07) produced by X and gamma radiation;
2) Hp(10) and Hp(0.07) produced by X, gamma and beta radiation;
3) Hp(10) produced by X and gamma radiation;
4) Hp(10) generated by neutron radiation;
5) Hp(10) produced by X, gamma and neutron radiation;
6) Hp (0.07) produced by X, gamma and beta radiation.
Note 1. Unless otherwise stated, when referring to "dose" in this standard, it refers to the individual dose equivalent.
Note 2. Unless otherwise stated, when reference is made to "dose meter" in this standard, it is meant to include all personal dose equivalents.
This standard specifies the requirements for dosimeters and their associated readout systems (if provided).
This standard specifies the general characteristics, general test methods, radiation characteristics, and electrical, mechanical, safety, and environmental characteristics of the above dosimeters.
Only the relevant readout system is required to affect the personal dose equivalent readout accuracy and alarm settings and to the reader to the dose meter Resounding requirements.
This standard also specifies the classification of instruments used in Appendix C based on different measurement capabilities.
This standard does not include special requirements for accident or emergency dosimetry, although dosimeters can be used for this purpose. This standard does not apply to testing Dosimeters that measure pulsed radiation (eg, radiation produced by most medical X-ray diagnostic equipment, linear accelerators, or similar devices).
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2900.81-2008 Electrotechnical terminology Nuclear instrument physical phenomena and basic concepts (IEC 60050-393:2003, IDT) GB/T 2900.82-2008 Electrotechnical terminology nuclear instrumentation, systems, equipment and detectors (IEC 60050-394:2007, IDT) GB 4208-2008 Shell protection class (IP code) (IEC 60529:2001, IDT) GB/T 6592-2010 Performance representation of electrical and electronic measuring equipment (IEC 60359:2001, IDT) GB/T 12162.1-2000 X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response Part. Radiation characteristics and production methods (idtISO 4037-1.1996) GB/T 12162.2-2004 X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response Part. Dosimetry of reference radiation for energy protection from 80 keV to 1.3 MeV and 4 MeV to 9 MeV (ISO 4037-2:1997, IDT) GB/T 12162.3-2004 X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response Part. Calibration of site dosimeters and personal dosimeters and determination of their energy effects and angular responses (ISO 4037-3:1999, IDT) GB/T 12162.4-2010 X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response Part. Calibration of sites and personal dosimeters in low-energy X-ray reference radiation fields (ISO 4037-4:2004, IDT) GB/T 12164.1-2008 beta reference radiation Part 1. Method of production (ISO 6980-1:2006, IDT) GB/T 14055.1-2008 Neutron reference radiation Part 1. Radiation characteristics and method of production (ISO 8529-1:2001, IDT) GB/T 14055.2-2012 Neutron reference radiation Part 2. Radiation protection meter calibration associated with characterization of the basic amount of radiation field Foundation (ISO 8529-2:2000, IDT) GB/T 16511-1996 Random documentation for electrical and electronic measuring equipment (idtIEC 61187.1993) GB/T 17626.4-2008 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test (IEC 61000-4-4:2004, IDT) GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology Surge (impact) immunity test (IEC 61000-4-5.
2005, IDT)
GB/T 17626.11-2008 Electromagnetic compatibility test and measurement techniques Immunity to voltage dips, short interruptions and voltage changes Test (IEC 61000-4-11:2004, IDT) ISO 6980-2:2004 Nuclear energy beta reference radiation Part 2. Basis of calibration associated with characterization of the fundamental quantities of radiation fields (Nuclear energy-Referencebeta-Particleradiation-Part 2: Calibrationfundamentalsrelatedtobasicquantities Charaterizingtheradiationfield) ISO 6980-3:2006 Nuclear energy beta reference radiation - Part 3. Calibration of site and personal dosimeters and energy and angular response OK (Nuclearenergy-Referencebeta-Particleradiation-Part 3: Calibrationofareaandperaonal Dosemetersanddeterminationoftheirresponseasafunctionofbetaradiationenergyandangleofinci-Dence) ISO 8529-3:1998 Neutron reference radiation - Part 3. Calibration of physic and personal dosimeters and determination of energy and angular response (Referenceneutronradiation-Part 3: Calibrationofareaandperaonaldosemetersanddetermination Oftheirresponseasafunctionofbetaradiationenergyandangleofincidence) ISO 12789-1:2008 Reference radiation field simulation of neutron field in workplace - Part 1. Radiation characteristics and method of production (Ref-erenceradiationfields-Simulatedworkplaceneutronfields-Part 1: Characteristicsandmethodsof Production) ISO 12789-2:2008 Reference Radiation Fields Simulating the Neutron Field of the Workplace Part 2. Basis of Calibration Related to Basic Quantity (Referenceradiationfields-Simulatedworkplaceneutronfields-Part 2: Calibrationfundamentalsre-Lattitothebasicquantities) ISO/IEC Guide 98-3.2008 Measurement uncertainty - Part 3. Guidance for the determination of measurement uncertainty (GUM..1995) [Uncertaintyofmeasurement-Part 3. Guidetotheexpressionofuncertaintyinmeasurement(GUM.
1995)]
ISO/IEC Guide 98-3.2008/Suppl.1 Calculation of the distribution of radiation propagation using the Monte Carlo method and Amendment 1 (2009) [PropagationofdistributionsusingaMonteCarlomethodandCorr.1 (2009)] IEC 60068-2-31:2008 Environmental test Part 2-31. Test test Ec. Impact caused by rough handling, mainly used for Equipment type samples (Environmentaltesting-Part 2-31. Tests-Test-Ec. Roughhandlingshocks, originally Forequipment-typespecimens) IEC 60086-1:2007 Primary batteries Part 1. General (Primarybatteries-Part 1. General) IEC 60086-2:2007 Primary batteries Part 2. Dimensions and electrical performance requirements (Primarybatteries-Part 2.
Physicalandelectricalspecifications) Electromagnetic compatibility (EMC) - Part 4-2. Test and measurement techniques Electrostatic discharge test [Electro-Magneticcompatibility(EMC)-Part 4-3. Testing and measurementtechniques-Electrostatic Dischargetest] IEC 61000-4-3:2008 Electromagnetic compatibility (EMC) Part 4-3. Test and measurement techniques Test [Electromagneticcompatibility(EMC)-Part 4-3. Testingand measurementtechniques-Radiated, radio-frequency, electromagneticfieldimmunitytest] IEC 61000-4-6:2008 Electromagnetic compatibility (EMC) Part 4-6. Test and measurement techniques Immunity [Electromagneticcompatibility(EMC)-Part 4-6. Testingandmeasurementtechniques-Im-Munitytoconducteddisturbances,inducedbyradio-frequency] Electromagnetic compatibility (EMC) - Part 4-8. Test and measurement techniques - Power frequency magnetic field immunity test [E-Lectromagneticcompatibility(EMC)-Part 4-8. Testing and measurementtechniques-Power Frequencymagneticfieldimmunitytest] IEC 61000-6-2:2005 Electromagnetic compatibility - Part 6-2. Immunity test in a general standard industrial environment [Electromag-Neticcompatibility(EMC)-Part 6-2. Genericstandards-Immunityforindustrialenvironments] IEC/T R62461.2006 Determination of measurement uncertainty for radiation protection instruments (Radiationprotectioninstrumenta-tion-Determinationofuncertaintyinmeasurement) ICRUREPORT 51.1993 Quantity and units used in radiation protection dosimetry (Quantitiesandunitsinradiation) Protectiondosimetry)
3 Terms and definitions
GB/T 2900.81-2008, GB/T 2900.82-2008, GB/T 6592-2010 and ICRUREPORT 51..1993 and the following terms and definitions apply to this document.
Acceptance test acceptance test in order to prove to the customer that the instrument meets the contract test requirements specified in its specifications.
Calibration (for this standard) calibration(forthepurposeofthisstandard) Quantitatively determine the parameters under a controllable standard test condition where all m relative response values rq are 1 and all l deviations Dp are 0.
The relationship between the calibration factor N0 and the nonlinear response correction value rn is examined.
Calibration factor Under the specified reference conditions, the ratio of the agreed true value Hr of the specified reference radiation at the test point to the indicated value Gr. Expressed as.
Note 1. (See GB/T 12162.3-2004) When the dosimeter indication is measured, the calibration factor N is dimensionless. The dosimeter accurately indicates the agreed true value when the calibration factor is 1.
Note 2. (see GB/T 12162.3-2004) The reciprocal of the calibration factor is equal to the response under the reference conditions. The calibration factor is only relative to the reference condition, and the ringing it should be possible to target any conditions at the time of measurement.
Note 3. (See GB/T 12162.3-2004) The value of the calibration factor may vary with the measured value. At this point the doser is said to have a non-linear response.
Coefficient of variation the ratio of the standard deviation s of a set of n measured values xi to its arithmetic mean x.
N-1sum
Xi-x( ) 2 (2)
Synthetic standard measurement uncertainty combinedstandardmeasurementuncertainty Synthetic standard uncertainty combinedstandarduncertainty Uc Standard measurement uncertainty obtained using different standard measurement uncertainty associated with various inputs in the measurement model.
Note. If the input quantities are relevant in the measurement model, the covariance should also be considered when calculating the synthetic standard measurement uncertainty, see ISO/IEC Guide 98-3.
2.3.4 of 2008.
Quantitative value of conventionalquantityvalue the agreed value of the amount of conventionalvalueofquantity Conventional value A quantity that is assigned to a given purpose by convention.
Note 1. This concept is sometimes expressed by the "contractual truth value of quantity", but it is discouraged.
Note 2. Sometimes the approximate quantitative value is an estimate of the true value.
Note 3. It is generally considered that the approximate quantitative value has only a very low measurement uncertainty (possibly zero).
Note 4. In this standard, the quantity is the dose equivalent (rate).
Nonlinear response correction correctionfornon-constantresponse Rn Under the specified conditions, there is only the ratio of the response R obtained by the measured change to the reference response R0. Expressed as.
Note. An instrument with a linear response is equal to 1.
Detector device detectorassembly A device consisting of a radiation detector and associated components required to calibrate or determine the response.
Note. The calibration results are only valid for this detector unit.
Example. Calibrate a personal dosimeter using a phantom. The personal dosimeter and phantom and the combination of the readout instrument and the cable form a detector device.
Deviation
The difference between the indicated value (two different values) given by the dose equivalent (rate) meter for the same measured value when the amount of influence is continuously presented.
D=G-Gr (4)
In the formula.
G --- the indicated value of the affected quantity;
Gr --- indication value under reference conditions.
Note 1. This term is derived from 311-07-03 "Changes in the amount of influence" in GB/T 2900.77-2008, in order to avoid confusion (changes in (indicative values)" and "changes in response", which is referred to as "deviation" in this standard.
Note 2. The deviation can be positive or negative depending on the increase or decrease of the indicated value.
Note 3. Deviation is particularly important for the amount of S-type impact.
3.10
Effective measurement range effectiverangeofmeasurement the performance of the dosimeter meets the range of measured values required by this standard.
3.11
Extended measurement uncertainty expandedmeasurementuncertainty Extended uncertainty expandeduncertainty the product of the synthetic standard measurement uncertainty and a coefficient greater than one.
Note 1. This factor depends on the probability distribution of th...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6592-2010Electrical and electronic measuring equipment -- Expression of performance
- GB/T 12162.1-2000X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods
- GB/T 12162.2-2004X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1.3 MeV and 4 MeV to 9 MeV
- GB/T 12162.3-2004X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as s function of photon energy - Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
- GB/T 12164.1-2008Reference beta-particle radiation - Part 1: Methods of production
- GB/T 14055.1-2008Neutron reference radiations - Part 1: Characteristics and methods of production
GB/T 2900.81-2008 · IEC 60050 · GB/T 2900.82-2008 · GB 4208-2008 · IEC 60529 · IEC 60359 · ISO 4037 · GB/T 12162.4-2010 · ISO 6980 · ISO 8529 · GB/T 14055.2-2012 · GB/T 16511-1996 · IEC 61000 · ISO 12789 · IEC 60068 · IEC 60086
How to Download GB/T 13161-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6592-2010 — Electrical and electronic measuring equipment -- Expression of performance
GB/T 18088-2026 — Sampling for entry and exit animal quarantine
GB/T 47983-2026 — Technical requirements for on-board energy consumption monitoring of passenger cars
Secure payment via Stripe
Payments accepted
GB/T 13161-2015
$605.00