GB/T 12162.1-2025X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (40 pages)

Need quotation for your management?

Get a formal quotation for GB/T 12162.1-2025 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Recommended

Issue date

October 31, 2025

Implementation date

May 1, 2026

Scope

GB/T 12162.1-2025 (X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods) is available as an English-translated PDF.

GB/T 12162.1-2025 — This document describes the radiation characteristics of X and gamma reference radiation used to calibrate protective level dosimeters and dose rate meters according to operational usage. and the method of generation.

This document applies to reference radiation fields with an air kerma rate of not less than 1 µGy·h-1. This document does not apply to air kerma rates below this lower limit where special consideration is required for (natural) background radiation.

The radiometric properties specified in Chapters 4 through 6 provide ample publicly available information to define matching or characterize reference fields, enabling the determination of radiometric properties relative to phantom phases.

The target has an operational uncertainty of approximately 6% to 10% (k=2). The X-ray radiation fields described in Appendices A to C are not included. It was designated as the reference X-ray radiation field.

Note. The.2000 version of this document includes some additional radioactive materials, including fluorescent radiation, gamma radiation S-Am from the radionuclide 241Am, and high-energy photons.

The information regarding irradiated R-Ti and R-Ni, which is unavailable due to the lack of published information, has been removed from this document. Among these, fluorescent radiation is the most widely used.

The gamma radiation S-Am of radionuclide 241Am is listed almost unchanged in Annexes A and B. Annex C provides additional information specified by the quality index.

X-ray radiation field. Chapters 4 through 6 describe methods for generating a set of reference radiations within a specific photon energy range; these clauses define these radiations.

The characteristics of [the radiation source].

The three sets of reference radiation are. a) Continuous filtering of X-ray radiation within an energy range of approximately 8 keV to 330 keV; b) Gamma radiation emitted by radioactive nuclides in the energy range of 600 keV to 1.3 MeV; c) Photon radiation generated by the accelerator in the energy range of 4MeV to 9MeV.

Select the most suitable reference radiation field from Table 1, which covers all reference radiation fields specified in Chapters 4 through 6.

The quality, but excluding the radiation given in Appendix A, Appendix B and Appendix C. The requirements and methods given in Chapters 4 through 6 are to reduce the expanded uncertainty of the operational quantities related to the phantom in the reference field.

(k=2) is approximately 6%~10%, therefore two methods for generating it are proposed. The first method is to generate a "matching reference field" whose properties are fully characterized so that the transformation coefficients recommended in ISO 4037-3 can be used.

The energy spectrum distribution of the "matching reference field" differs only slightly from that of the nominal reference field, and is described in detail in GB/T 12162.2-2025.

The procedure described has been verified. For the matched reference radiation field, ISO 4037-3 only applies to the specified distance between the source and the dosimeter (e.g., Recommended conversion factors are given for 1.0m and 2.5m.

For other distances, the user decides whether to use these conversion factors. If two If the values are very similar, for example, differing by only 2% or less, use linear interpolation.

The second method is to generate a "characterization reference field." This is accomplished by determining the conversion coefficients using energy dispersive spectroscopy, or by using a secondary standard dose.

The instrument directly measures the desired value. This method is applicable to any radiometric substance and the measured quantity, and, if applicable, to any phantom and angle of incidence of radiation.

Furthermore, the requirements for the parameters of the specified reference radiation depend on the defined depth in the phantom, namely 0.07 mm, 3 mm, and 10 mm, so different the depth requirements are different.

Therefore, for a given radiation field at a depth of 0.07 mm to "match the reference field," it is not the same as for a depth of 10 mm to "match the reference field." it is not "matching a reference field", but "characterizing a reference field".

When the air kerma rate is not less than 1 µGy/h, the conversion at any distance can be determined. coefficient. Both methods require charged particle equilibrium in the reference field.

However, this is not always the case in the radiation field used to calibrate dosimeters. This is especially true at a reference depth d where there is no intrinsic charged particle equilibrium photon energy, which depends on the energy and the actual composition of the reference depth d.

Electrons with energies higher than 65 keV, 0.75 MeV, and 2.1 MeV will penetrate ICRU arrays of 0.07 mm, 3 mm, and 10 mm, respectively.

Found what you need?

Document preview — GB/T 12162.1-2025

National Standard of the People's Republic of China

ICS
17.240
Classification
F 85
Replacing
GB/T 12162.1-2000

Issued by: State Administration for Market Regulation

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Continuous reference filtering of X-ray radiation 6.
  • 5 Gamma radiation emitted by radioactive nuclides
  • 6 Energy 4MeV~9MeV photon radiation
  • Appendix A (Informative) For fluorescence X-rays 30 where sufficient information is lacking for matching and characterization fields
  • Appendix B (Informative) For gamma-radiation emitted by radionuclide 241Am with insufficient information on matching and characterization fields
  • Appendix C (Informative) Continuous Filtering of X-rays Based on Quality Index
  • References

Foreword

This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents".

Drafting.

This document is Section 1 of GB/T 12162 "X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response".

GB/T 12162 has been published in four parts.

---Part 1: Radiation Characteristics and Generation Methods;

---Part 2: Dosimetry for Radiation Protection in the Energy Ranges of 8keV to 1.3MeV and 4MeV to 9MeV;

---Part 3: Calibration of site dosimeters and personal dosimeters and determination of their energy and angular responses;

---Part 4: Calibration of site and personal dosimeters in low-energy X-ray reference radiation fields.

This document replaces GB/T 12162.1-2000 "X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response".

"Radiation Part 1: Radiation Characteristics and Generation Methods", compared with GB/T 12162.1-2000, mainly differs in structure and editorial changes.

The technological changes are as follows.

a) The concepts of a matched reference radiation field and a characteristic reference radiation field were added (see 4.1.1);

b) Verification of the matched reference radiation field has been added (see 4.5);

c) Parameters such as high pressure, filter purity, and thickness tolerance limits from nominal values have been added, and these limits are consistent with the volume used.

Model is limited (see Tables 7 and 8);

d) The upper limit of the X-ray reference radiation of the filtered beam was changed from 300 kV to 400 kV (see Tables 3-6, 2000 edition).

Tables 3-7);

e) R-Ni and R-Ti in 241Am, fluorescence radiation, and high-energy gamma radiation have been removed (see Chapter 5, 6.2.1, and 2000 edition).

7.2.3).

This document is equivalent to ISO 4037-1:2019 Radiation protection for the calibration of dosimeters and dose rate meters and for the determination of their energy response.

And gamma reference radiation, Part 1: Radiation characteristics and generation methods.

The following minimal editorial changes have been made to this document.

---The standard title has been changed to "X and gamma Reference Radiation for Calibration of Dosimeters and Dose Rate Meters and Determination of Their Energy Response, Part 1" Part 1: Radiation Characteristics and Generation Methods.

Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.

This document was proposed and is under the jurisdiction of the National Nuclear Energy Standardization Technical Committee (SAC/TC58).

Introduction

Establishing X-ray and gamma-ray reference radiation is a prerequisite for calibrating dosimeters and dose rate meters and determining their energy responses; therefore, it is necessary to specify the corresponding radiation.

Field and measurement methods.

GB/T 12162 "X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response" is applicable to...

For calibrating dosimeters and dose rate meters and determining their energy response using X and gamma reference radiation, with the development of domestic nuclear energy, nuclear medicine and radiotherapy, the development of nuclear technology applications, environmental protection, and national defense has led to a continuous increase in the number of locations and applications involving radioactivity, and the demand for dosimeters and dose rates has also grown.

The use of instruments is increasing significantly, and the accompanying demand for metrological calibration is also growing. Therefore, calibration of dosimeters and dose rate meters and determination of their energy are crucial.

The response to X and gamma reference radiation has increased significantly in China in recent years.

GB/T 12162 "X and gamma reference radiation for calibrating dosimeters and dose rate meters and determining their energy response" is proposed to consist of 4 parts.

constitute.

---Part 1: Radiation Characteristics and Generation Methods. The purpose is to define the radiation characteristics and generation methods of three sets of six series of reference radiation.

Methods include continuous filtering of X-ray radiation in the energy range of approximately 8 keV to 330 keV, and filtering of X-ray radiation in the energy range of 600 keV to 1.3 MeV.

Gamma radiation emitted by radionuclides in the energy range, and photon radiation generated by accelerators in the energy range of 4 MeV to 9 MeV.

Radiation; according to the usage method of the conversion coefficient from air kerma to operational practical quantity, the "matching reference radiation" and "table radiation" are specified respectively.

"Reference radiation" guides the establishment of a reference radiation field for calibrating dosimeters and dose rate meters and determining their energy responses.

---Part 2: Dosimetry for Radiation Protection in the energy ranges of 8 keV to 1.3 MeV and 4 MeV to 9 MeV. Purpose the document specifies the methods and procedures for determining reference radiation dosimetry values of 8keV~1.3MeV and 4MeV~9MeV, providing guidance for their application.

Air kerma in the approximate energy ranges of 8keV to 1.3MeV and 4MeV to 9MeV, and above 1µGy/h.

Determination of reference radiation standard values.

---Part 3: Calibration of site dosimeters and personal dosimeters and determination of their energy and angular responses. The purpose is to specify...

Methods and requirements for personal and regional dosimeter calibration, as well as conversion coefficients from air kerma to operational quantities, to guide the use of...

Calibration of dosimeters and personal dosimeters for personal and location monitoring in radiation protection.

---Part 4: Calibration of site and personal dosimeters in low-energy X-ray reference radiation fields, with the aim of specifying the calibration of dosimeters below 30 keV.

Special requirements for the calibration of personal and regional dosimeters in low-energy X-ray reference radiation fields, providing guidance for the calibration of site dosimeters (rate meters) and personal dosimeters.

Calibration of the rate meter in low-energy photon reference radiation and determination of its energy response and angular response.

GB/T 12162 (all parts) systematically defines and specifies the technical requirements for X-ray and gamma reference radiation, effectively standardizing this type of radiation.

The performance of metrology equipment effectively improves the accuracy and reliability of dosimeter and dose rate meter calibration results, thereby reducing the cost of dosimeter and dose rate meter calibration.

The technical risks and costs for manufacturers.

Used for calibrating dosimeters and dose rate meters and determining its energy response X and gamma reference radiation Part 1: Radiation Characteristics and Generation Methods

1 Scope

This document describes the radiation characteristics of X and gamma reference radiation used to calibrate protective level dosimeters and dose rate meters according to operational usage.

and the method of generation.

This document applies to reference radiation fields with an air kerma rate of not less than 1 µGy·h-1.

This document does not apply to air kerma rates below this lower limit where special consideration is required for (natural) background radiation.

The radiometric properties specified in Chapters 4 through 6 provide ample publicly available information to define matching or characterize reference fields, enabling the determination of radiometric properties relative to phantom phases.

The target has an operational uncertainty of approximately 6% to 10% (k=2). The X-ray radiation fields described in Appendices A to C are not included.

It was designated as the reference X-ray radiation field.

Note. The.2000 version of this document includes some additional radioactive materials, including fluorescent radiation, gamma radiation S-Am from the radionuclide 241Am, and high-energy photons.

The information regarding irradiated R-Ti and R-Ni, which is unavailable due to the lack of published information, has been removed from this document. Among these, fluorescent radiation is the most widely used.

The gamma radiation S-Am of radionuclide 241Am is listed almost unchanged in Annexes A and B. Annex C provides additional information specified by the quality index.

X-ray radiation field.

Chapters 4 through 6 describe methods for generating a set of reference radiations within a specific photon energy range; these clauses define these radiations.

The characteristics of [the radiation source]. The three sets of reference radiation are.

a) Continuous filtering of X-ray radiation within an energy range of approximately 8 keV to 330 keV;

b) Gamma radiation emitted by radioactive nuclides in the energy range of 600 keV to 1.3 MeV;

c) Photon radiation generated by the accelerator in the energy range of 4MeV to 9MeV.

Select the most suitable reference radiation field from Table 1, which covers all reference radiation fields specified in Chapters 4 through 6.

The quality, but excluding the radiation given in Appendix A, Appendix B and Appendix C.

The requirements and methods given in Chapters 4 through 6 are to reduce the expanded uncertainty of the operational quantities related to the phantom in the reference field.

(k=2) is approximately 6%~10%, therefore two methods for generating it are proposed.

The first method is to generate a "matching reference field" whose properties are fully characterized so that the transformation coefficients recommended in ISO 4037-3 can be used.

The energy spectrum distribution of the "matching reference field" differs only slightly from that of the nominal reference field, and is described in detail in GB/T 12162.2-2025.

The procedure described has been verified. For the matched reference radiation field, ISO 4037-3 only applies to the specified distance between the source and the dosimeter (e.g., Recommended conversion factors are given for 1.0m and 2.5m. For other distances, the user decides whether to use these conversion factors. If two If the values are very similar, for example, differing by only 2% or less, use linear interpolation.

The second method is to generate a "characterization reference field." This is accomplished by determining the conversion coefficients using energy dispersive spectroscopy, or by using a secondary standard dose.

The instrument directly measures the desired value. This method is applicable to any radiometric substance and the measured quantity, and, if applicable, to any phantom and angle of incidence of radiation.

Furthermore, the requirements for the parameters of the specified reference radiation depend on the defined depth in the phantom, namely 0.07 mm, 3 mm, and 10 mm, so different the depth requirements are different. Therefore, for a given radiation field at a depth of 0.07 mm to "match the reference field," it is not the same as for a depth of 10 mm to "match the reference field." it is not "matching a reference field", but "characterizing a reference field". When the air kerma rate is not less than 1 µGy/h, the conversion at any distance can be determined.

coefficient.

Both methods require charged particle equilibrium in the reference field. However, this is not always the case in the radiation field used to calibrate dosimeters.

This is especially true at a reference depth d where there is no intrinsic charged particle equilibrium photon energy, which depends on the energy and the actual composition of the reference depth d.

Electrons with energies higher than 65 keV, 0.75 MeV, and 2.1 MeV will penetrate ICRU arrays of 0.07 mm, 3 mm, and 10 mm, respectively.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 40 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 12162.1-2025

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
40 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 12162.1-2025

$710.00