GB/T 12162.4-2010X and gamma reference radiation for calibrating dosimeters and dose rate meters and for determining their response as a function of photon energy -- Part 4: Calibration of area and personal dosimeters in low energy X reference radiation fields (English PDF)

用于校准剂量仪和剂量率仪及确定其能量响应的X和γ参考辐射 第4部分:低能X射线参考辐射场中场所和个人剂量仪的校准

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB/T 12162.4-2010 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

November 10, 2010

Implementation date

May 1, 2011

Scope

GB/T 12162.4-2010 is the English-translated version of 用于校准剂量仪和剂量率仪及确定其能量响应的X和γ参考辐射 第4部分:低能X射线参考辐射场中场所和个人剂量仪的校准.

GB/T 12162.4-2010 — This section GB/T 12162 specifies the reference in the low energy X-ray radiation field calibration options and personal dose (rate) meters and determining field the individual dose (rate) meter energy response and angular response of the method.

This section provides an accurate determination of low energy photon radiation spectrum from the air kerma Kinetic energy to Hp (10) and H * (10) of the conversion coefficient, and a method of directly by an appropriate instrument calibration standard according to these quantities.

This section applies to low-energy X-ray radiation field calibration reference sites and personal dose (rate) meters and to determine places and personal dose (Rate) meter energy response and angular response.

Found what you need?

Document preview — GB/T 12162.4-2010

National Standard of the People's Republic of China

ICS
17.240
Classification
F 85

Issued by: Standardization Administration of China

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Symbols
  • General Method 5 calibration and determine the response of
  • Generation and low energy X reference radiation characteristics 6
  • 6.1 Overview
  • 6.2 Voltage
  • 6.3 Radiation field uniformity and scattered radiation
  • 6.4 Spectral fluence and conversion factor of
  • 7 Low energy reference radiation dosimetry
  • 7.1 Overview
  • Use standard instrument 7.2
  • 8 Calibration response and determining the energy and angular response of
  • 8.1 Overview
  • Select calibration method 8.2 of
  • 8.3 With standard measuring instrument calibration Ka
  • 8.4 With a standard measurement instrument calibration ICRU dose equivalents
  • 8.5 9 Expression of Uncertainty
  • Appendix A (normative) air density correction
  • Annex B (informative) Measurement of pulse amplitude spectrum
  • References

Foreword

GB/T 12162 "for calibrating dosemeters and dose rate meters and for determining their response of X and gamma reference radiations" is divided into four parts.

--- Part 1. Radiation characteristics and production methods;

--- Part 2. Energy range of radiation protection is 8keV ~ 1.3MeV and 4MeV ~ 9MeV reference radiation dose Measurement;

--- Part 3. place dosimeters and personal dosimeters calibration response to determining its energy and angular response;

--- Part 4. low-energy X-ray radiation reference field sites and personal dosimeters calibration.

This section GB/T Part of 412,162.

This part of GB/T 12162 other part has a close relationship. GB/T 12162.1-2000 describes a photon reference radiation Production and characteristics; GB/T 12162.2-2004 describes the reference radiation dosimetry; GB/T 12162.3-2004 depicts a International Commission on Radiation Units and Measurements (ICRU) the amount of practical radiation protection [1,2,3] and determine the calibration dosimeters and dose rate meter response process Preface; GB/T 12162.4 described for low-energy X reference radiation field of special methods.

This part identical with ISO 4037-4:2004 "for calibrating dosemeters and dose rate meters and for determining their response of X and gamma reference Radiation - Part 4. low-energy X-ray radiation reference field sites and personal dosimeters calibration. " Compared with the original standard, only a series Series of modified to comply with the relevant requirements of national standards, the main change is as follows.

--- Delete the original standard foreword and introduction;

--- Other adaptations.

Appendix A of this section is normative appendix, Appendix B is an informative annex.

This part is proposed by the China National Nuclear Corporation.

This part of the National Nuclear Energy Standardization Technical Committee (SAC/TC58) centralized.

This section drafted by. China Institute of Atomic Energy.

1 Scope

This section GB/T 12162 specifies the reference in the low energy X-ray radiation field calibration options and personal dose (rate) meters and determining field the individual dose (rate) meter energy response and angular response of the method. This section provides an accurate determination of low energy photon radiation spectrum from the air kerma Kinetic energy to Hp (10) and H * (10) of the conversion coefficient, and a method of directly by an appropriate instrument calibration standard according to these quantities.

This section applies to low-energy X-ray radiation field calibration reference sites and personal dose (rate) meters and to determine places and personal dose (Rate) meter energy response and angular response.

2 Normative references

The following documents contain provisions which, through reference GB/T 12162 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

X and gamma GB/T 12162.1-2000 for calibrating dosemeters and dose rate meters and for determining their response reference radiation first Part I. Radiation characteristics and production methods (idtISO 4037-1.1996) X and gamma GB/T 12162.2-2004 for calibrating dosemeters and dose rate meters and for determining their response reference radiation 2 Parts. the energy range of radiation protection is 8keV ~ 1.3 MeV and 4 MeV ~ 9 MeV reference radiation dosimetry (ISO 4037-2:1997, IDT) GB/T 12162.3-2004 for calibrating dosemeters and dose rate meters and for determining their response of X and gamma reference radiations 3 Part. place dosimeters and personal dosimeters calibrated response and its energy and angular response is determined (ISO 4037-3:1999, IDT) JJF1059 Measurement Uncertainty and representation no. ICRU51 report quantities and units of radiation protection dosimetry

3 Terms and Definitions

And the following terms and definitions GB/T 12162.3-2004 established applicable to this section.

Low-energy X-ray reference radiation lowenergyX-rayreferenceradiation GB/T 12162.1-2000 and GB/T 12162.3-2004 specified nominal tube voltage lower than 30kV (including 30kV) by Radiation quality.

Note. These radiation qualities for all filters and fluorescence radiation beam reference radiation.

Spectral fluence Fluence Phi function of photon energy E distribution.

PhiE = dPhidE

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 12162.4-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 12162.4-2010

$305.00