GB 6969-2005 (Fire suction hose) is available as an English-translated PDF.
GB 6969-2005 — This document defines the terminology for fire-fighting water suction pipes, and specifies their classification and model designation, performance requirements, inspection rules, marking, and instructions for use. The book and packaging describe the corresponding testing methods. This document applies to fire hoses used for pumping water or foam liquid during firefighting and rescue operations.
Found what you need?
Document preview — GB 6969-2005
National Standard of the People's Republic of China
- ICS
- 13.220.20
- Classification
- C 84
- Replacing
- GB 6969-2005
Issued by: State Administration for Market Regulation, Standardization Administration of China
Contents
- Preface
- 1.Scope1
- 2 Normative References1
- 3.Terms and Definitions1
- 4.Classification and Models1
- 4.1 Classification1
- 4.2 Model2
- 5 Performance Requirements3
- 5.1 Structure and Materials3
- 5.2 Appearance Quality3
- 5.3 Inner diameter of suction pipe3
- 5.4 Suction pipe length3
- 5.5 Interface Performance3
- 5.6 Mass per unit length3
- 5.7 Rated working pressure, test pressure, and burst pressure4
- 5.8 Vacuum resistance4
- 5.9 Bending performance under load4
- 5.10 Bending resistance4
- 5.11 Flexural Performance5
- 5.12 Coil Performance5
- 5.13 Interlayer bond strength5
- 5.14 Aging resistance5
- 6.Test Methods5
- 6.1 Structural and Material Inspection5
- 6.2 Appearance Quality Inspection5
- 6.3 Measurement of the inner diameter of the suction pipe5
- 6.4 Measurement of suction pipe length5
- 6.5 Interface Performance Check6
- 6.6 Measurement of mass per unit length6
- 6.7 Hydrostatic Test and Burst Test6
- 6.8 Vacuum Resistance Test6
- 6.9 Load Bending Performance Test7
- 6.10 Bending resistance test8
- 6.11 Flexural Performance Test9
- 6.12 Coil performance test10
- 6.13 Interlayer bond strength test11
- 6.14 UV radiation resistance test11
- 6.15 Ozone Resistance Test12
- 7.Inspection Rule12
- 7.1 Inspection Category12
- 7.2 Type Testing12
- 7.3 Factory Inspection12
- 8.Markings, instructions for use, and packaging13
- 8.1 Mark13
- 8.2 Instruction Manual13
- 8.3 Packaging13
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents".
Drafting.
This document replaces GB 6969-2005 "Fire-fighting Suction Hose". Compared with GB 6969-2005, the main differences are structural adjustments and editorial changes.
In addition, the main technological changes are as follows.
a) A new chapter on "Terms and Definitions" has been added (see Chapter 3);
b) A new chapter on "Classification and Models" has been added (see Chapter 4);
c) Increased structural and material requirements for plastic suction pipes (see 5.1);
d) The appearance quality requirements have been changed (see 5.2, 4.11 of the.2005 version);
e) The requirements for the inner diameter of the suction pipe have been changed (see 5.3, 4.1 in the.2005 edition);
f) The requirements for the length of the suction pipe have been changed (see 5.4, 4.1 of the.2005 edition);
g) Interface performance requirements and inspection methods have been added (see 5.5 and 6.5);
h) The mass requirement per unit length has been changed (see 5.6, 4.2 of the.2005 edition);
i) The requirements for rated working pressure, test pressure, and burst pressure of plastic water suction pipes have been increased (see 5.7);
j) Vacuum resistance requirements have been changed (see 5.8, 4.5 in the.2005 edition);
k) The load-bending performance requirements have been changed (see 5.9, 4.6 of the.2005 edition);
l) The bending resistance requirements and test methods for straight-tube suction pipes have been revised (see 5.10, 6.10, and 4.7 and 5.6 of the.2005 edition);
m) The requirements and test methods for the UV radiation resistance of plastic water suction pipes have been added (see 5.14.1, 6.14);
(n) The ozone resistance requirements and test methods for rubber suction pipes have been added (see 5.14.2, 6.15);
o) The inspection rules have been changed (see Chapter 7, Chapter 6 in the.2005 edition);
p) An instruction manual and packaging have been added (see Chapter 8).
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed and is under the jurisdiction of the State Fire and Rescue Administration.
The release history of this document and the document it replaces is as follows.
---First published as GB 6969-1986 in 1986, and revised for the first time in.2005;
---This is the second revision.
Fire suction hose
1 Scope
This document defines the terminology for fire-fighting water suction pipes, and specifies their classification and model designation, performance requirements, inspection rules, marking, and instructions for use.
The book and packaging describe the corresponding testing methods.
This document applies to fire hoses used for pumping water or foam liquid during firefighting and rescue operations.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
GB 12514 Technical Requirements for Fire Protection Interfaces
GB/T 14905-2020 Determination of interlayer adhesive strength of rubber and plastic hoses
GB/T 16422.2-2022 Plastics - Laboratory Light Source Exposure Test Methods - Part 2.Xenon Arc Lamps
GB/T 24134-2009 Evaluation of ozone resistance under static conditions for rubber and plastic hoses
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Composed of a hose and a fire hose connection, it is used to draw water or foam liquid from natural water sources, fire pools, outdoor fire hydrants, foam storage tanks, etc.
Component assembly.
Note. Hereinafter referred to as "suction pipe".
3.2
Straight suction hose
A straight, non-bending suction pipe.
3.3
coiled suction hose
It is in a coiled state and can be unfolded or pulled out during operation; it is a flexible suction hose.
4 Classification and Model
4.1 Classification
4.1.1 Suction pipes can be classified according to their shape as follows.
a) Straight-tube water suction pipe;
b) Coil-type suction pipe.
4.1.2 Water suction pipes can be classified according to their material characteristics as follows.
END: Draft Version (GB 6969-2026)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
How to Download GB 6969-2005
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 12514.1-2005 — Fire coupling - Part 1: General technical conditions for fire coupling
GB 12514.2-2006 — Fire coupling - Part 2: Patterns and basic parameters for fire snap-types coupling
GB 12514-2026 — Technical specifications for fire couplings
Secure payment via Stripe
Payments accepted
GB 6969-2005
$130.00