Scope

GB 6220-2009 (Respiratory Protection - Long Tube Breathing Apparatus) is available as an English-translated PDF.

GB 6220-2009 — This Standard specifies the product classification and composition, technical requirements, test methods and marking of long tube breathing apparatus.

The products specified in this Standard are not suitable for fire-fighting and rescue sites.

Found what you need?

Document preview — GB 6220-2009

National Standard of the People's Republic of China

ICS
13.340.30
Classification
C 73

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative References...5
  • 3 Terms and Definitions...5
  • 4 Product Classification and Composition...8
  • 5 Technical Requirements...8
  • 6 Test Methods...14
  • 7 Marking...17

Foreword

The Sub-clauses 5.2, 5.3, 5.4, and 7.2 in this Standard are mandatory, while the

rest are recommended.

This Standard replaced GB 6220-1986 Long Tube Respirators; and GB 6221-1986

Performance Test Methods of Long Tube Respirators.

Compared with GB 6220-1986 Long Tube Respirators; and GB 6221-1986

Performance Test Methods of Long Tube Respirators, this Standard made the major

changes as follows.

--- Add the low flowrate warning requirements for the high-pressure air mask;

--- Add the strength requirements for the structure and parts;

--- Add the technical requirements and test methods of the high-pressure portion,

warning device, pressure display device for the air-supply mask of the high-

pressure cylinder, as well as the gas cylinder;

--- Modify the technical requirements of the mask lens;

--- Modify the test methods of breathing resistance;

--- Add the test requirements for air-supply valve at different openings;

--- Add the high and low temperature adaptability requirements and the test

methods;

--- Add the marking requirements.

This Standard was proposed by State Administration of Work Safety.

This Standard shall be under the jurisdiction of National Technical Committee on

Personal Protective Equipment of Standardization Administration of China (SAC/TC

112).

Drafting organization of this Standard. Beijing Municipal Institute of Labor Protection.

Participating drafting organizations of this Standard. Institute of Chemical Defense;

and MSA (China) Safety Equipment Co., Ltd.

Chief drafting staffs of this Standard. Yang Wenfen, Ding Songtao, Xiao Yiqing, Yao

Haifeng, Chen Zhuowei, Zang Lanlan, Zhou Yunyun, and Luo Mufu.

The historical editions replaced by this Standard are as follows.

--- GB 6220-1986;

--- GB 6221-1986.

Respiratory Protection -

Long Tube Breathing Apparatus

1 Scope

This Standard specifies the product classification and composition, technical

requirements, test methods and marking of long tube breathing apparatus.

The products specified in this Standard are not suitable for fire-fighting and rescue

sites.

2 Normative References

The provisions in following documents become the provisions of this Standard through

reference in this Standard. For dated references, the subsequent amendments

(excluding corrigendum) or revisions do not apply to this Standard, however, parties

who reach an agreement based on this Standard are encouraged to study if the latest

versions of these documents are applicable. For undated references, the latest edition

of the referenced document applies.

GB/T 1226 General Pressure Gauge

GB 2890-2009 Respiratory Protection - Non-Powered Air-Purifying Respirators

GB 5099 Seamless Steel Gas Cylinders

GB/T 16556-2007 Self-Contained Open-Circuit Compressed Air Breathing

Apparatus

DOT-CFFC Basic Requirements for Fully Wrapped Carbon-Fiber Reinforced

Aluminum Lined Cylinders

3 Terms and Definitions

For the purposes of this Document, the following terms and definitions apply.

3.1 Long tube breathing apparatus

The protective article that protects the wearer's respiratory organs from the

surrounding air and transports clean air for breathing through long tubes.

NOTE. Long tube breathing apparatus is divided into. self-inhalation long tube breathing

apparatus, powered long tube breathing apparatus, and long tube breathing apparatus with

high pressure.

3.1.1 Self-inhalation long tube breathing apparatus

The long tube breathing apparatus that allows the wearer to breathe spontaneously to

get fresh, clean air.

3.1.2 Powered long tube breathing apparatus

The long tube breathing apparatus that uses a fan or air compressor to deliver fresh,

clean air to the wearer.

3.1.3 Long tube breathing apparatus with high pressure

The long tube breathing apparatus that uses compressed air or high-pressure gas

cylinders to deliver clean air to the wearer.

NOTE 1.Also known as pressure demand long tube breathing apparatus.

NOTE 2.The long tube is a pressure-bearing component during gas transmission.

3.2 Breathing tube

The flexible and air-tight tube for connecting masks with long tube.

3.3 Straps

A ring or sleeve to secure a long tube to the waist of the wearer.

NOTE. The straps include a belt and a hanging ring.

3.4 Long tube

Air-tight, flexible and long breathing tube for conveying clean air.

3.5 Tight-fitting face masks

A mask that can cover the nose, mouth, and face, or a mask that can cover the eyes,

nose, and mouth, and close to the head and face.

NOTE 1.The tight-fitting face mask is used to ensure the isolation of the working environment

by the tight-fitting frame.

NOTE 2.Tight-fitting face mask are divided into full mask and half mask.

3.5.1 Full mask

A tight-fitting face mask that is tight-fitting the head, and covers the eyes, face, nose,

mouth, and jaw.

3.5.2 Half mask

A tight-fitting face mask that is tight-fitting the head, and covers the mouth and nose,

or covers the mouth, nose, and jaw.

3.6 Loose-fitting facepiece

The air introduction device for positive pressure breathing protection equipment covers

only the eyes, nose and mouth, and tight-fitting the face.

3.7 Continuous flow valve

In an air-supply long tube breathing apparatus, a device that allows the wearer to

adjust the amount of inspiratory air.

3.8 Low-resistance filters

In the self-inhalation long tube breathing apparatus, a large-pore filter device is

installed at the inlet end of the long tube to prevent foreign matter from entering.

NOTE. This filter can prevent foreign matter above 0.15mm from passing through.

3.9 Demand valve

Air-supply valve

The valve controlled by the breathing action of the lungs, it opens when needed and

supplies a breathable gas.

3.10 Warning device

A device that warns the wearer that respiratory protection is about to or has lost

effective protection.

3.11 Static pressure

After the positive pressure device of the air supply valve is opened, the pressure in the

mask cavity when the airway of the respirator is balanced.

3.12 High pressure

The absolute pressure with air pressure greater than or equal to 10 MPa.

3.13 Medium pressure

Pressures between 6kPa and 1MPa.

3.14 Low pressure

Pressures above atmospheric pressure and not exceeding 6kPa.

3.15 Dead space

The volume of gas re-inhaled from the previous exhalation.

NOTE. It is expressed by the volume fraction of carbon dioxide in the inhaled air.

4 Product Classification and Composition

The classification, composition, working environment, air supply source and pressure-

bearing capacity of typical long tube breathing apparatus are shown in Table 1.

Table 1 -- Classification and Composition of Long Tube Breathing Apparatus

Type of long tube

breathing

apparatus

Major component and order of system composition Air-supply source

Self-inhalation

long tube

breathing

apparatus Tight-fitting

face mask a

Breathing

tube a

Low pressure

long tube a Low-resistance filters

a Air a

Powered long

tube breathing

apparatus

Breathing

tube a +

continuous

flow valve a

Low pressure

long tube a Filter

Fan a

Air a Air

compressor a

Long tube

breathing

apparatus with

high pressure

Mask a

Breathing

tube a + air-

supply valve b

Medium

pressure long

tube b

High pressure

reducer c Filter

c High pressure air source c

Located

environment On-site working environment Guaranteed working environment

a Bear the low-pressure components;

b Bear the medium-pressure components;

c Bear the high-pressure components.

5 Technical Requirements

5.1 General requirements

5.1.1 Materials
5.1.1.1 Materials that are in direct contact with the head and face shall be harmless or

non-allergenic, and the surface of metal parts shall be anti-corrosive.

5.1.1.2 The material shall have sufficient strength and elasticity, and shall not be

damaged or deformed during normal service life.

5.1.1.3 The parts that may enter the work site shall be able to withstand the cleaning

or disinfection treatment recommended by the manufacturer.

5.1.1.4 Long tubes shall be airtight and resistant to the penetration of external liquids.
5.1.2 Structure
5.1.2.1 Components shall not be prone to structural damage; and their design,

composition and installation shall not cause any danger to users.

5.1.2.2 The headband shall be adjustable; and shall firmly fix the mask on the face;

and there shall be no obvious compression or tenderness when worn.

5.1.2.3 The mask shall have a wide field of vision, and there shall be no distortion of

the vision. The lens shall not be affected by fogging and other conditions that affect

vision.

5.1.2.4 The breathing tube and air-supply mask shall not restrict the user's head

movement or motion.

5.1.2.5 When the fan air-supply device stops working, it shall be able to switch to the

backup air-supply device or change to the self-inhalation working mode and warn the

guardian.

5.1.2.6 The length of the long tube shall be no greater than 80m.

NOTE. Long tube breathing apparatus longer than 80m shall be additionally tested in

accordance with the manufacturer's instructions to ensure safe and comfortable use.

5.1.2.7 During normal operation, the breathing apparatus shall be designed so that

each long tube can only supply one mask. Under special circumstances, each long

tube can only supply a maximum of two masks.

5.1.2.8 Self-inhalation long tube breathing apparatus shall be provided with low-

resistance filters to prevent foreign matter from entering.

5.1.2.9 Connections with different pressure ranges shall not be interchanged.
5.1.2.10 It is not allowed to design and install the air filter on the waist or mask.
5.1.3 Overall performance
5.1.3.1 The design of the mask shall avoid any tension or discomfort caused to the

wearer by improper air velocity or distribution.

5.1.3.2 When the wearer is in a crouching position or working in a space-constrained

environment, the long tube shall not hinder its movement.

5.1.3.3 In workplaces where a helmet is required, a long tube respirator mask shall not

prevent the helmet from being worn.

5.1.3.4 The straps shall be able to fix the breathing tube or medium pressure tube

behind or on the side of the wearer without affecting the operation. The width of the

strap shall be no less than 40mm.

5.1.3.5 The parts of the breathing apparatus that need to be operated by the wearer

shall be within reach and can be identified by touch. All adjustable parts shall not be

accidentally changed during use.

5.1.3.6 Long tube shall be tested according to 6.2 and the tensile strength shall be

greater than 1000N.

5.2 Performance requirements of low-pressure components

5.2.1 Test according to 6.3.When the continuous flow valve used for the tight-fitting

face mask is on the minimum opening, the ventilation flow rate shall be greater than

30 L/min. When the continuous flow valve used for the loose-fitting facepiece is on the

minimum opening, the ventilation flow rate shall be greater than 115 L/min.

NOTE. Bypass is allowed to ensure minimum flow. When bypass is used to ensure the flow,

the continuous flow valve is allowed to close.

5.2.2 The leakage rate of tight-fitting face mask shall meet the requirements of 5.1.6

in GB 2890-2009.

5.2.3 Test according to 6.4.The respiratory resistance of the mask shall meet the

requirements in Table 2.

Table 2 -- Respiratory Resistance Requirements

Test item

Air-supply mode

Self-inhalation Continuous air-supply Air-supply by high-pressure

Inhalation resistance/Pa Inside pressure of the mask > -300

Inside pressure of the

mask > -100

Inside pressure of the

mask > 0

Exhalation resistance/Pa < 1000

5.2.4 Test according to 6.5.The static pressure in the cavity of the mask shall be no

greater than 500Pa.

5.2.5 The air tightness of the exhalation valve shall meet the requirements of relevant

clauses of the mask exhalation valve in GB 2890-2009.

5.2.6 Test according to 6.6.The continuous operation performance of the blower shall

be able to work normally without abnormal phenomena.

5.2.7 Test high and low temperature adaptability according to 6.7.

a) It shall be free of stiffness, cracks, detached parts, and stickiness;

b) The leakage rate shall meet the requirements of 5.2.2;

c) Respiratory resistance shall meet the requirements of 5.2.3.

5.2.8 Test the air supply volume of the fan according to 6.8.The air volume at the inlet

of the long tube shall be greater than 100 L/min; and the air pressure shall be greater

than 1300Pa.

5.2.9 Test the minimum air supply volume according to 6.9.The minimum air supply

volume at the inlet of the mask shall be greater than 30 L/min.

5.2.10 Test the strength of the straps according to 6.10.The straps shall be able to

withstand 1000N tension without damage.

5.2.11 The dead space of the mask shall meet the requirements of 5.1.6 in GB 2890-

2009.

5.2.12 The field of view of the mask shall meet the requirements of 5.1.7 in GB 2890-

2009.

5.2.13 The observation window of the mask shall meet the requirements of 5.1.9 in GB

2890-2009.

5.2.14 The strength of the headband shall meet the requirements of 5.1.11 in GB 2890-

2009.

5.2.15 Test the connection strength according to 6.12 in GB 2890-2009.All connection

points shall not slip, break or plastically deform when they are subjected to an axial

tensile force of 250N for 10s.

5.2.16 For the powered long tube breathing apparatus, the continuous flow valve shall

meet the requirements of 5.2.3 at the maximum and minimum openings.

5.3 Performance requirements of medium-pressure components

Test according to 6.11.The pipeline (including connection parts) connected to the air

supply valve shall be able to withstand 2 times the working pressure of the pressure

reducer relief valve or at least 3MPa; take whichever is higher as the test pressure,

keep it for 15min.

5.4 Performance requirements for high-pressure components

5.4.1 High-pressure tube joints shall not exceed 3 places.
5.4.2 The long tube breathing apparatus with high pressure shall be provided with a

low-flow warning device. When the gas flow at the outlet of the long tube is lower than

the set flow, a signal for help is sent to the monitor.

5.4.3 The anti-particle performance of the long tube breathing apparatus with high

pressure shall meet the requirements of 5.12 in GB/T 16556-2007.

5.4.4 The air-tightness of the long tube breathing apparatus with high pressure shall

meet the requirements of 5.23 in GB/T 16556-2007.

5.4.5 Test the pressure resistance of high-pressure parts according to 6.11.Metal parts

that withstand high pressures bear at least 1.5 times the working pressure of gas

cylinders, and non-metal parts that withstand high pressures bear at least twice the

working pressure of gas cylinders.

5.4.6 Steel cylinders shall comply with the provisions of GB 5099; and composite

cylinders shall comply with the provisions of DOT-CFFC.

5.4.7 Test the gas delivery reliability of breathing tube and long tube according to 6.12.

There shall be no restriction or obstruction of air flow. The reduction in gas flow shall

not exceed 10% of the specified test air flow. After 10 min of the test, there shall be no

observable distortion.

5.4.8 The gas cylinder valve shall meet the requirements of 5.15 in GB/T 16556-2007.
5.4.9 The pressure reducer shall meet the following requirements.
5.4.9.1 When a long tube breathing apparatus is provided with a pressure reducer, any

adjustable part of the medium pressure section shall be firmly locked and appropriate

sealing measures shall be taken to enable illegal adjustment to be observed.

5.4.9.2 When a downstream component of a long tube breathing apparatus cannot

withstand the full pressure in the cylinder, a pressure relief valve shall be set.

5.4.9.3 For a long tube breathing apparatus with a pressure-reducer pressure relief

valve, the pressure-reducer pressure relief valve shall be capable of passing a flow of

400 L/min at a pressure not exceeding 3MPa; after such valve is activated, the

inhalation resistance and exhalation resistance shall be no greater than 2.5kPa.

5.4.10 A long tube breathing apparatus with high pressure shall be installed with a

pressure gauge that complies with the provisions of GB/T 1226.The pressure gauge

and its connecting tube shall meet the following requirements.

a) The shell shall be equipped with a rubber protective sleeve. When the gas

cylinder valve is opened, the pressure gauge should be able to read the pressure

in the gas cylinder so that the single cylinder pressure or the equilibrium pressure

can be measured separately;

b) The position of the pressure gauge shall be easy to read the pressure value;

c) The minimum value of the pressure gauge range is 0, the highest value shall be

at least 5 MPa higher than the rated working pressure of the cylinder; the

accuracy shall be less than Level-2.5; and the minimum division value shall be

no greater than 1MPa;

d) The pressure value on the pressure gauge shall be clearly readable in poor

lighting conditions;

e) Test according to 6.13.When the pressure gauge and connecting tube are

removed from the long tube breathing apparatus, the leakage air flow under the

pressure of 20MPa shall be no greater than 25 L/min.

5.4.11 The warning device shall meet the following requirements.

a) In any case, the information provided by the warning device and pressure gauge

(see 5.4.10) shall be complementary.

b) Long tube breathing apparatus shall be provided with appropriate warning device,

which shall alert the monitor when the cylinder pressure drops to a

predetermined value.

c) The warning device shall be activated automatically when the cylinder valve is

opened.

d) When the pressure in the cylinder drops to (5.5 ± 0.5) MPa, or when the

remaining gas in the cylinder is at least 200L, the warning device should activate

the alarm.

e) After the warning device is activated, a continuous audible alarm or an

intermittent audible alarm shall be issued. The sound intensity shall be no less

than 90 dB (A), and the sound frequency range shall be between 2000 Hz and

4000 Hz. The duration of the continuous audible alarm shall be no less than 15s;

the intermittent audible alarm response shall be no less than 60s. After that, the

warning device shall continue to alarm until the cylinder pressure drops to 1 MPa.

f) After the warning device is activated, the wearer shall be able to continue using

the long tube breathing apparatus normally.

g) Test according to 6.14.From the start of the pneumatic alarm to the pressure of

the cylinder dropping to 1MPa, the average gas consumption of the warning

device shall be no greater than 5 L/min.

6 Test Methods

6.1 General of test conditions

6.1.1 The laboratory environment required in this Clause is. temperature (20 ± 2) °C,

humidity 30% ~ 70%.

6.1.2 The test head mold shall meet the requirements of 6.9.2.3 in GB 2890-2009.
6.1.3 The accuracy and precision requirements of the measuring instruments used in

this Clause are as follows.

a) Gas flowmeter. accuracy of Class-2.5, accurate to 0.2 L/min;

b) Gasometer. accuracy of Class-2.5, accurate to 0.2L;

c) Gas pressure gauge. accuracy of Class-1, accurate to 0.1 MPa or 1 Pa;

d) thermometer. accuracy of Class-1, accurate to 0.1°C;

e) Timer. accuracy of Class-1, accurate to 0.1s.

6.2 Tensile strength of long tube

Take a long tube of appropriate length; one end is tied (bundled) with a 1000N weight,

the other end is tied (bundled) on a loading fixture; and loaded at a speed of (100 ± 5)

mm/min. When the weight is lifted, the long tube is considered to pass the test without

failure or break.

6.3 Minimum flow test of continuous flow valve

Use a fan passing the test of 6.6 to supply air to the long tube. Connect the flow meter

at the outlet of the continuous flow valve; adjust the continuous flow valve to the

minimum; and take the reading of flow meter.

6.4 Respiratory resistance

6.4.1 Test equipment

a) Artificial lung. breathing frequency 20 times/min; respiratory flow (40 ± 1) L/min;

sine wave airflow;

b) Pressure measuring device. dynamic pressure measuring device; record the

curve; read the maximum and minimum values.

6.4.2 Test procedure

Wear the mask on the test head mold; and adjust the rest to the working state. The

breathing interface is connected to the artificial lung. The artificial lung is started.

Measure the pressure within the mask, which is the respiratory resistance.

NOTE 1.The high-pressure system shall be tested from the highest working pressure to 1MPa.

NOTE 2.For systems with continuous flow valves, the maximum and minimum opening

conditions shall be tested separately.

6.5 Static pressure test

6.5.1 Powered long tube breathing apparatus

Wear the mask and the breathing tube on the test head mold; and use the fan or the

air compressor equipped to the product, which are tested according to 6.6 to supply

air to the long tube; adjust the continuous flow valve to the maximum opening; and use

a pressure gauge to measure the pressure inside the mask under stable air flow;

whichever is greater.

6.5.2 Long tube breathing apparatus with high pressure

Wear the mask and the breathing tube on the test head mold; turn on the automatic

positive pressure mechanism; and use a pressure gauge to measure the pressure

inside the mask under stable air flow; whichever is greater.

Wear the mask and the breathing tube on the test head mold; open the forced air

supply (flushing) mechanism to the maximum opening; and use a pressure gauge to

measure the pressure inside the mask under stable air flow; whichever is greater.

6.6 Test of continuous working performance of blower

Wear the mask on the test head mold; use a blower to supply air to the mask through

a long tube; adjust the continuous flow valve to the minimum opening; and work

continuously for 24h.

6.7 High and low temperature adaptability

Take the samples containing the long tube and place them in (50 ± 2) °C and (-20 ±

2) °C environment for 3h; then take the corresponding test within 5min after taking out.

6.8 Test of air output

Use a fan that has passed the test of 6.6; and connect a flow meter in series at the

outlet of the fan or the air compressor provided to the product to take the reading of

flow meter.

Use a fan that has passed the test of 6.6; and connect a hose of an appropriate length

at the outlet of the fan or air compressor provided to the product. The opening of the

hose is placed 130mm below the water surface, and air bubbles shall be generated.

6.9 Minimum air output

Use a fan that has passed the test of 6.6 to supply air to the long tube; adjust the

continuous flow valve to the minimum opening; and connect a flow meter in series with

the air outlet of the breathing tube to take reading of the flow meter.

6.10 Tension of strap

Place the waistband and the strap on the test chucks, respectively; and apply a tension

of (1000 ± 10) N to the two test chucks for 5 min.

NOTE. When loading, the test sample shall not be impacted.

6.11 Pressure resistance

The pressure loading device is installed at one end of the tee; and the remaining two

ends of the tee are connected in series in the pipeline. All valves of the pressurized

component are opened, and the load is slowly applied. The loading medium is oil or

water. Load to the specified pressure, keep for 15min then unload.

6.12 Reliability of air transmission

Connect the flow meter at the air outlet of the breathing tube; and supply air at the air

inlet of the long tube; and adjust the flow to the use flow rate specified by the

manufacturer or (100 ± 2) L/min. Complete the following tests.

a) Wrap the long tube and breathing tube for 3 laps on a log with diameter of 30mm;

and take the reading of the flowmeter.

b) Clamp the long tube between wooden boards with length of 500mm; apply 1000N

pressure; and take the reading of the flowmeter.

NOTE. The use flow rate specified by the manufacturer shall be preferred.

6.13 Leakage of pressure gauge

Adjust the upstream air supply pressure of the pressure gauge to 20 MPa. Remove

the pressure gauge and replace it with a flow meter to measure at least 5 min.

6.14 Air consumption of warning device

Adjust the upstream air supply pressure of the warning device to the highest working

pressure of the high-pressure air source ~ 1 MPa. Connect the rear end of the alarm

whistle to the flow meter. Measure one point for each 5 MPa reduction and take the

average value.

7 Marking

7.1 The product shall have a permanent marking and instruction manual.

7.2 The permanent marking shall include.

a) The name of the product;

b) Standard number;

c) The manufacturer's logo;

d) Model or size (if applicable).

7.3 The instruction manual shall include the following.

a) The name of the product;

b) Manufacturer information;

c) The type of mask;

d) Standard number;

e) Production date or batch number;

f) Use method;

g) The shelf life;

h) Cleaning and maintenance recommendations;

i) Storage conditions;

j) Certification mark.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Download GB 6220-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 6220-2009

$135.00