GB 4706.39-2008Household and similar electrical appliances - Safety - Particular requirements for commercial electric grillers and toasters (English PDF)
家用和类似用途电器的安全 商用电烤炉和烤面包炉的特殊要求
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for GB 4706.39-2008 in 30 minutes.
Issued by
State Administration for Market Regulation; Standardization Administration of China
Level / Type
National · Mandatory
Issue date
December 30, 2008
Implementation date
April 1, 2010
Scope
GB 4706.39-2008 is the English-translated version of 家用和类似用途电器的安全 商用电烤炉和烤面包炉的特殊要求.
GB 4706.39-2008 — Household and similar electrical appliances - Safety - Particular requirements for commercial electric grillers and toasters
Found what you need?
Document preview — GB 4706.39-2008
National Standard of the People's Republic of China
- ICS
- 13.120
Contents
- Foreword1
- Introduction2
- Normative references3
- General requirements4
- Marking and instructions5
- Protection against access to live parts6
- Start electric appliances7
- Fever8
- Void9
- Transient overvoltage10
- Moisture resistance11
- Leakage current and electric strength12
Foreword
All technical contents of this section is mandatory.
GB 4706 "and similar household electrical appliances," it consists of several components, Part 1 General Requirements for the other parts of special Claim.
This part is the part 4706 of 39 GB. This section should be safe first and GB 4706.1-2005 "Household and similar electrical appliances Part 1: General Requirements, "with the use.
This section is equivalent to using IEC 60335-2-48:2002 "Safety part 2 and similar household electrical appliances. commercial electric oven and baked Particular requirements for bread oven "and its Amendment No. 1 (Ed4.0,2008-02).
For ease of use, this part of the IEC 60335-2-48 following editorial changes made.
Word A) "first part" to "GB 4706.1-2005";
b) with a decimal point "." instead of as a decimal point "." this section instead of GB 4706.39-2003 "household and similar electrical appliances commercial electric ovens and toasters special Claim" this section GB 4706.39-2003 The main difference is as follows.
--- Note canceled 101 6.2, added "use on the desktop appliance at least IPX3, other implements at least IPX4" of Claim;
--- canceled 6.101;
Added Note 11.7 in --- 101;
--- revised 16.2 in leakage current limit;
--- Chapter 18 does not apply and instead apply;
Chapter 21 --- increase in the content of the package visible to the heating element hot tube impact test;
--- modify the content of 22.101;
--- increased 29.2;
--- canceled 30.3;
--- modify the content 30.101 in the combustion test.
APPENDIX This section N is normative.
This section was proposed by China Light Industry Federation.
This part of the jurisdiction of the National Standardization Technical Committee appliances (SAC/TC46).
This part was drafted. Beijing Institute of mechanical services, Yu Fu-kitchen equipment (Shenzhen) Co., Ltd., the new wheat Machinery (Wuxi) Ltd., a Shanghai-Food Machinery Co., Ltd., Guangdong Electric Co., Ltd. Pu Yi Li.
Introduction
It has been assumed in the drafting of this section, a person appropriately qualified and experienced to implement the provisions of this section.
This portion is recognized that the use of household electrical appliances and the like under normal conditions noted when the manufacturer's instructions for the appliance an acceptable level of risk international protection of electrical, mechanical, thermal, radiation and fire, it also includes the use may be expected to occur Abnormal circumstances, and in view of electromagnetic interference affects the way for the safe operation of the appliance.
In developing this part has been as much as possible into account the requirements of GB 16895 in order to make electrical appliances when connecting to the grid Gas wiring rules requires coordinated.
If a number of functions GB 4706 appliance involves special requirements in different part of the special requirements, as far as is reasonable in the circumstances Under the special requirements of the relevant standards should be applied to each function separately. If applicable, taking into account the influence of one function to other functions.
When the special requirements not included in Part 1 of the appended claims when hazardous, Part 1 applies.
Note 1.The meaning of the special requirements of the Technical Committee has decided there is no need to redefine the general requirements for special requirements.
This part is a matter of security appliance product family standards, and standards covering the same subject at the same level in the same category in priority.
Note 2.When the application GB 4706 series of standards on general requirements and specific requirements covering the risk of the same level and the same standard does not apply to categories already General Requirements section has been taken into account. For example, in regard to many of the requirements for the surface temperature of the appliance, similar standards, such as ISO 13732-1 on heat Surface requirements, except for the part not applicable to the standard 1 or special requirements.
An appliance that complies text of this section, when examined and tested, found to have other features that will be covered by the requirements of this damage and when the level of security, it will not be considered to comply with the safety guidelines in this section.
Product use various materials or various forms of structures other than specified in this part, this may be the product according to the present section the intent of these requirements for inspection and testing. If found to be substantially equivalent, it can be determined which comply with this part.
GB 4706.39-2008/IEC 60335-2-48:2002 Household and similar electrical appliances - Safety Particular requirements for commercial electric grillers and toasters Range 1 GB 4706.1-2005 in this chapter replaced by the following.
This section relates GB 4706 is not for home use and safety of commercial electric oven toasters. For one phase and neutral connection Single-phase line tool, which does not exceed the rated voltage of 250V, other apparatus does not exceed 480V.
Or continuously rotating electric oven and toasters and similar baked using radiant heat appliances, such as electric furnace rotary barbecue, grilled plate, also Within the scope of this section.
101 NOTE. These instruments used such as restaurants, food stores, such as hospitals and bakeries, meat shops and the like commercial enterprises.
Using other forms of energy appliance, it is also within the scope of this part of the electrical portion.
This section deals with common risk caused by such equipment.
102 Note. the following should be noted.
--- intended for use on vehicles, vessels or aircraft equipment, allows additional requirements necessary;
--- In many countries, additional requirements under national health, labor protection, water supply and other similar authority;
--- For appliance designed for outdoor use, allow the necessary additional requirements.
103 NOTE. This does not apply to.
--- designed specifically for industrial use appliances;
--- appliances used in place of a corrosive or explosive atmosphere (dust, vapor or gas) and other special state;
--- for the mass production of food utensils continuous operation;
--- single, electric griddles (GB 4706.37).
2 Normative references
This chapter in GB 4706.1-2005 is applicable.
Definition 3
The following terms and definitions apply to this section.
GB 4706.1-2005 in this chapter except as follows, are applicable.
3.1.4 Addition.
101 Note. rated input power is the sum of all the individual elements of the input power within the appliance can be operated at the same time; there may be several such combinations, the most Large combined to determine the input power rated input power.
3.1.9 article replaced by the following.
The appliance is operated under the following conditions.
Appliance load operation and all the controllers for the user to operate to maximum limits. As with a timer, then it does not work.
As with the door, cover, or the reflecting plate drip tray arrangement accordance with the manufacturer's instructions, if not provide instructions, to fully open the door, the minimum drip pan in Position grill placed as high as possible.
If the appliance does not load does not work, you should pay attention to the manufacturer's instructions.
A motor mounted within the appliance, taking into account the manufacturer's instructions, under the most severe conditions that may occur in normal use, as expected Run.
GB 4706.39-2008/IEC 60335-2-48:2002 3.101 A major food baked by radiant heat appliance in its interior.
3.102
A specially designed for bread or similar baked browned appliances with radiant heat.
3.103
An appliance mobile products during baking.
3.104
Fixed structure comprising dedicated supply facilities, for the supply and the appliance together with the installation structure.
4 General requirements
This chapter in GB 4706.1-2005 is applicable.
General conditions for 5 tests GB 4706.1-2005 in this chapter except as follows, are applicable.
This chapter 5.10 Addition.
When the appliance is installed in combination with other apparatus or fixed installation on the wall, should take measures to avoid electric shock or harmful retaining water, and reached the Indicated with the protection requirements specification.
101 Note. fence or may require appropriate additional tool for testing purposes.
5.101 appliance is equipped with an electric motor even still be tested as heating appliances.
5.102 joint assembly with the appliance or other apparatus with other apparatus are tested in accordance with the requirements of this section. Other instruments related press Requirements of the standard work at the same time.
Category 6
GB 4706.1-2005 in this chapter except as follows, are applicable.
6.1 article replaced by the following.
About shock protection category, the appliance should belong to the class I.
Compliance is checked by inspection and relevant tests.
6.2 Addition.
Used on the desktop appliance at least IPX3, other implements at least IPX4.
7 Marking and instructions
GB 4706.1-2005 in this chapter except as follows, are applicable.
7.1 Addition.
In addition, the appliance shall be marked.
Water source appliance intends connected, by its pressure or range of pressures in kPa, but who has been otherwise specified in the specification.
7.6 Addition.
Add the following symbols.
GB/T 5465.2 (idt IEC 60417-1) -5021 equipotential GB 4706.39-2008/IEC 60335-2-48:2002
7.12 Addition.
If the label on the appliance GB/T 5465.2 (idt IEC 60417-1) specified symbol 5021, should explain its meaning.
For physical, sensory or mental defective or lacking experience and knowledge of people (including children), this description does not apply.
7.12.1 article replaced by the following.
The appliance shall be accompanied by instructions, special precautions necessary for installation details. When the appliance is mounted in combination with other appliances or fixed when installing wall should be provided on how to prepare for guaranteed electric shock and harmful ingress of water blocking detailed description fully protected. As will be more than one device the control device in combination with a separate housing, the installation should provide detailed instructions. User maintenance, such as cleaning, etc., should also be provided Instructions. Description specification should not use water jet cleaning appliance.
For permanently connected to the fixed wiring and leakage current may exceed 10mA appliance, especially long-term in an open state or stopped Use, or when first installed, the specification intended to provide protection on the installation (such as earth leakage protection relay) recommendation rating.
Compliance is checked by inspection.
7.12.4 Addition.
Having a separate control panel for a number of built-in appliances station apparatus to be used, which should provide instructions for use. only the control panel with the finger Given appliance is connected to avoid possible danger.
7.15 Addition.
If the flag is not set to fixed appliances it can be seen that after installation, the description should also use tags on or applied as a the instructions. The label may be applied in the vicinity of the fixing device after installation.
101 Note. Built-in appliances are examples of fixed appliances.
7.101 During the test of clause 11, if the angle of the test plate or stationary appliances top planar more measurements of the angular side and rear walls Temperature rise than 65K, and (or) during test Chapter 19, above and below the top plate or stationary appliances angle planar test Temperature exceeds 125K side walls, the instructions provided by the manufacturer shall include warning points, and the warning is also included in the appliance attached to the on a permanent label.
Warning. During the installation, not the appliance is placed near the kitchen on certain surfaces or walls, partitions, equipment and the like, unless they are is not combustible material or surface covered with heat insulating incombustible material, and to observe the fire regulations.
Compliance is checked by inspection.
7.102 predetermined equipotential bonding terminal application GB/T 5465.2 (idt IEC 60417) 5021 symbols indicated.
These signs should not be placed screws, removable washers or other member may be removed when the wire is connected.
Compliance is checked by inspection.
8 Protection against access to live parts
GB 4706.1-2005 in this chapter except as follows, are applicable.
Each heating element is easily fork or similar pointed object is accidentally touched during normal use shall be protected 8.101 (except bread baking oven groove), so that A charging member which comes into contact with such objects can not.
By GB/T 16842 (IEC 61032, IDT) of the test probe 12 is inserted around all parts of the charging member can enter to determine Whether qualified. Not exert significant force on the test probe.
9 Start electric appliances
GB 4706.1-2005 in this chapter except as follows, are applicable.
Voltage conditions all conform to 9.101 Chapter fan motor 11 for cooling requirements, should be possible in practical use start up.
Compliance is checked by starting the motor three times at 0.85 times rated voltage to check. Start the motor in the test room temperature.
Under each condition to start work are ready to start the motor, for automatic appliances, at the beginning of the normal operating cycle Under conditions, between two consecutive start, the motor can reach a stationary state. Centrifugal apparatus not equipped with a motor start switch GB 4706.39-2008/IEC 60335-2-48:2002 when, at 1.06 times the rated voltage of the above test is repeated.
In all the above cases, the motor should be able to run up and should not affect the safe way, overload protection devices shall not operate.
Note. During the test, the power supply voltage drop should not exceed 1%.
Power input and current 10 GB 4706.1-2005 in this chapter except as follows, are applicable.
10.1 Addition.
101 NOTE. For appliances having more than one heating element, the total input power may be determined (by measuring the other input of the power of each heating element See 3.1.4).
11 Fever
GB 4706.1-2005 in this chapter except as follows, are applicable.
11.2 Addition.
And the fixing device is greater than the mass on the floor without 40kg roller assembly, the appliance castors or the like, in accordance with the manufacturer's instructions Installation. If you do not provide a description, I think that these instruments are usually placed on the floor use.
11.4 article replaced by the following.
The appliance is operated under normal operating conditions, so that the total input power is 1.15 times the rated input power. If not simultaneously turned ON A heating element, each composition is tested under conditions that allow the configuration of the switch, and the circuit configuration is consistent with the presence of each of the switches the highest possible load.
If any of the appliance with the controller to limit the total input power, the controller may select this test can be applied to the most severe conditions One kind of electric heating elements to composition.
If the temperature rise of the motor, a transformer or an electronic circuit exceeds a limit value, the test is repeated at the appliance 1.06 times the rated voltage. in in this case, only temperature measurements of motors, transformers or electronic circuits.
11.7 article replaced by the following.
The appliance work continuously until steady conditions are established.
101 Note. The test duration should include more than one working cycle.
11.8 Addition.
For stationary appliances, back and side walls of the test corner, comprising a projecting part in front of the appliance, 65K temperature limits apply only to the appliance the following top plane. If the temperature rise above the plane of the base plate or exceeds this limit, the required 7.101 apply.
12 Void
Leakage current and electric strength at the operating temperature of 13 GB 4706.1-2005 in this chapter except as follows, are applicable.
13.2 piece of content for the following modifications.
Instead of class I stationary appliances with the following variation allowable leakage current value.
--- cord and plug for connecting the appliance. appliance-rated power input 1mA/kW, the maximum limit of 10mA;
--- other appliances. an appliance rated power input 1mA/kW, no maximum limit.
14 Transient overvoltage
This chapter in GB 4706.1-2005 is applicable.
15 Moisture resistance
GB 4706.1-2005 in this chapter except as follows, are applicable.
GB 4706.39-2008/IEC 60335-2-48:2002
15.1.1 Addition.
Further, IPX0, IPX1, IPX2, IPX3 IPX4 appliances and should be subjected to the following tests splash 5min.
101 using the apparatus shown in FIG. During the test, the water pressure should be adjusted to the bottom of the bowl from the water splashes 150mm. Usually on the ground for the of apparatus, the bowl on the floor; all other appliances, the appliance bowl on a horizontal support surface lowest edge is less than 50mm, so that the bowl Move around the appliance, so that the respective direction of the water splashed from the appliance. It should be noted not spray water directly to the appliance.
15.1.2 piece of content for the following modifications.
Commonly used on the desktop appliance, to put a support surface, the support surface than the side dimension of each appliance support surface orthogonal projection ruler Inch 15cm ± 5cm.
15.3 Addition.
101 Note. If this is not the entire tool into the humidity cabinet containing part of the electrical components is tested separately, but to pay attention to the situation within the appliance.
15.101 as water or cleaning and washing appliance and with a water switch, shall be constructed to ensure that the water flowing from the water can not switch contact electrification part.
Compliance is checked by the following test.
The appliance is connected to the water supply pressure having the maximum specified by the manufacturer of the water, the inlet valve fully open 1min. Tilt and Movable member, comprising a lid, are tilted or placed at the most unfavorable position. The aqueous outlet pipe rotatable switch position adjusted so that the water will yield the on those parts of life the most unfavorable results. This should be subjected to the electrical appliance by a predetermined strength test 16.3 immediately after treatment.
16 Leakage current and electric strength
GB 4706.1-2005...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
GB 4706.1-2005 · IEC 60335
How to Download GB 4706.39-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4706.100-2009 — Household and similar electrical appliances - Safety - Particular requirements for multifunctional shower room
GB 4706.101-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for drives for rolling shutters, awnings, blinds and similar equipment
GB 4706.104-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for heated gullies for roof drainage
Secure payment via Stripe
Payments accepted
GB 4706.39-2008
$135.00