GB 4706.37-2008Household and similar electrical appliances - Safety - Particular requirements for commercial electric griddles and griddle grills (English PDF)
家用和类似用途电器的安全 商用单双面电热铛的特殊要求
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for GB 4706.37-2008 in 30 minutes.
Issued by
State Administration for Market Regulation; Standardization Administration of China
Level / Type
National · Mandatory
Issue date
December 30, 2008
Implementation date
April 1, 2010
Scope
GB 4706.37-2008 is the English-translated version of 家用和类似用途电器的安全 商用单双面电热铛的特殊要求.
GB 4706.37-2008 — Household and similar electrical appliances - Safety - Particular requirements for commercial electric griddles and griddle grills
Found what you need?
Document preview — GB 4706.37-2008
National Standard of the People's Republic of China
- ICS
- 13.120
Contents
- Foreword1
- Introduction2
- Normative references3
- General requirements4
- Marking and instructions5
- Protection against access to live parts6
- Start electric appliances7
- Fever8
- Void9
Foreword
All technical contents of this section is mandatory.
GB 4706 "and similar household electrical appliances," it consists of several components, Part 1 General Requirements for the other parts of special Claim.
This section should GB 4706.1-2005.with "safe 1 Household and similar electrical appliances General requirements." this section is equivalent to using IEC 60335-2-38:2002 "Safety part 2 and similar household electrical appliances. a commercial single-sided heating Particular requirements clang "and Amendment 1 (Ed5.0,2008-02).
For ease of use, this part of the IEC 60335-2-38 following editorial changes made.
Word A) "first part" to "GB 4706.1-2005";
b) with a decimal point "." instead of as a decimal point "." this partial replacement GB 4706.37-2003 "and similar household electrical appliances special requirements for commercial electric griddles" this section GB 4706.37-2003 The main difference is as follows.
--- an increase of 3.104;
--- Note canceled 101 6.2, added "use on the desktop appliance at least IPX3, other implements at least IPX4" of Claim;
--- canceled 6.101;
--- increased 7.12.4,7.15;
13.2 --- added to the relevant content with respect to the glass surface of the ceramic heating element or a similar material;
--- increased 13.3;
--- increased 16.1;
--- modify 16.2 leakage current limit, the increased requirements for glass ceramic or similar material measuring leakage current;
--- increased 16.3;
--- modify the content of 22.101;
--- increased 29.2;
--- canceled 30.3;
--- modify the content 30.101 in the combustion test.
APPENDIX This section N is normative.
This section was proposed by China Light Industry Federation.
This part of the jurisdiction of the National Standardization Technical Committee appliances (SAC/TC46).
This part was drafted. Beijing Institute of mechanical services, Yu Fu-kitchen equipment (Shenzhen) Co., Ltd., Beijing Huamei cooking Machinery Co., Ltd., Guangzhou City, Guangdong Huadu District, Western Kitchen Equipment Factory, Beijing Silver Valley Electrical Co., Ltd., on the Hai Haike Hotel Equipment Manufacturing Co., Ltd., Beijing Industry and Trade Co., Ltd. with a new, Foshan Electrical Factory Conway.
Introduction
It has been assumed in the drafting of this section, a person appropriately qualified and experienced to implement the provisions of this section.
This portion is recognized that the use of household electrical appliances and the like under normal conditions noted when the manufacturer's instructions for the appliance an acceptable level of risk international protection of electrical, mechanical, thermal, radiation and fire, it also includes the use may be expected to occur Abnormal circumstances, and in view of electromagnetic interference affects the way for the safe operation of the appliance.
In developing this part has been as much as possible into account the requirements of GB 16895 in order to make electrical appliances when connecting to the grid Gas wiring rules requires coordinated.
If a number of functions GB 4706 appliance involves special requirements in different part of the special requirements, as far as is reasonable in the circumstances Under the special requirements of the relevant standards should be applied to each function separately. If applicable, taking into account the influence of one function to other functions.
When the special requirements not included in Part 1 of the appended claims when hazardous, Part 1 applies.
Note 1.The meaning of the special requirements of the Technical Committee has decided there is no need to redefine the general requirements for special requirements.
This part is a matter of security appliance product family standards, and standards covering the same subject at the same level in the same category in priority.
Note 2.When the application GB 4706 series of standards on general requirements and specific requirements covering the risk of the same level and the same standard does not apply to categories already General Requirements section has been taken into account. For example, in regard to many of the requirements for the surface temperature of the appliance, similar standards, such as ISO 13732-1 on heat Surface requirements, except for the part not applicable to the standard 1 or special requirements.
An appliance that complies text of this section, when examined and tested, found to have other features that will be covered by the requirements of this damage and when the level of security, it will not be considered to comply with the safety guidelines in this section.
Product use various materials or various forms of structures other than specified in this part, this may be the product according to the present section the intent of these requirements for inspection and testing. If found to be substantially equivalent, it can be determined which comply with this part.
GB 4706.37-2008/IEC 60335-2-38:2002 Household and similar electrical appliances - Safety Particular requirements for commercial electric griddles of Range 1 GB 4706.1-2005 in this chapter replaced by the following.
This section relates to the safety of non-GB 4706 exclusively for home use for commercial electric griddles. For the connection of one phase and neutral Single-phase appliances with a rated voltage not exceeding 250V, other apparatus does not exceed 480V.
101 NOTE. These instruments used such as restaurants, food stores, such as hospitals and bakeries, meat shops and the like commercial enterprises.
Using other forms of energy appliance, it is also within the scope of this part of the electrical portion.
This section deals with common risk caused by such equipment.
102 Note. the following should be noted.
--- intended for use on vehicles, vessels or aircraft equipment, allows additional requirements necessary;
--- In many countries, additional requirements under national health, labor protection, water supply and other similar authority.
103 NOTE. This does not apply to.
--- designed specifically for industrial use appliances;
--- appliances used in place of a corrosive or explosive atmosphere (dust, vapor or gas) and other special state;
--- for the mass production of food utensils continuous operation;
--- electric ovens and toasters (GB 4706.39);
--- provided with an appliance induction heating source.
2 Normative references
This chapter in GB 4706.1-2005 is applicable.
Definition 3
The following terms and definitions apply to this section.
GB 4706.1-2005 in this chapter except as follows, are applicable.
3.1.4 Addition.
101 Note. rated input power is the sum of all the individual elements of the input power within the appliance can be operated at the same time; there may be several such combinations, the most Large combined to determine the input power rated input power.
3.1.9 article replaced by the following.
The appliance is operated under the following conditions.
The appliance according to the manufacturer's instructions without load operation, while the controller to adjust a given temperature below the temperature at each of the controlled pan Measuring the hottest surfaces.
A first grading adjusted position controller, the temperature is greater than or equal to 275 °C. Period controller should be adjusted so that the temperature level within the entire cycle Mean 275 °C ± 5 °C. As this temperature is not reached, the controls set to the highest value.
Open electric griddles work or closed, whichever is more disadvantaged. In the closed position, with a heat-resistant, low thermal conductivity spacer the griddle plate from two spaced apart surfaces, isolation thickness 10mm, an area equal to the surface area of the smaller one of the two baking pan.
For electric griddles clang two surfaces are not controlled separately, the controller was adjusted so that the surface of the pan reaches the set direct control bar Pieces. When two faces are separately controlled, pan, pan setting condition of two surfaces are applicable.
GB 4706.37-2008/IEC 60335-2-38:2002 Motor mounted within the appliance, taking into account the manufacturer's instructions using, under the most severe conditions that may occur in normal use, as expected Work the way.
3.101
We intend to bake one kind of instrument by side for direct food contact with a heating surface.
3.102
One kind of going to be baking appliances through contact with the two sides of the food simultaneously heating surface directly.
3.103
Fixed structure comprising dedicated supply facilities, for the supply and the appliance together with the installation structure.
3.104
Since individual cooking appliance or the heating action of any member.
4 General requirements
This chapter in GB 4706.1-2005 is applicable.
General conditions for 5 tests GB 4706.1-2005 in this chapter except as follows, are applicable.
5.10 Addition.
When the appliance is installed in combination with other apparatus or fixed installation on the wall, should take measures to avoid electric shock or harmful retaining water, and reached the Indicated with the protection requirements specification.
101 Note. fence or may require appropriate additional tool for testing purposes.
5.101 appliance is equipped with an electric motor even still be tested as heating appliances.
5.102 joint assembly with the appliance or other apparatus with other apparatus are tested in accordance with the requirements of this section. Other instruments related press Requirements of the standard work at the same time.
5.103 Unless otherwise specified, the test conditions and requirements apply to two electric griddles and griddle surface.
Category 6
GB 4706.1-2005 in this chapter except as follows, are applicable.
6.1 article replaced by the following.
About shock protection category, the appliance should belong to the class I.
Compliance is checked by inspection and relevant tests.
6.2 Addition.
Used on the desktop appliance at least IPX3, other implements at least IPX4.
7 Marking and instructions
GB 4706.1-2005 in this chapter except as follows, are applicable.
7.1 Addition.
Furthermore, the appliance should be marked. water appliance is connected with the intention of which is represented by the water pressure or range of pressures kPa, it has been used in the description of the injection Except for those out.
7.6 Addition.
GB 4706.37-2008/IEC 60335-2-38:2002 GB/T 5465.2 (idt IEC 60417-1) -5021 equipotential
7.12 Addition.
If the appliance is equipped with a glass surface to provide protection for the charging member is a ceramic or the like, the specification shall include warning points.
Warning. If the surface is broken, the appliance immediately cut off the power or related components!
Appliance having a glass ceramic surface of the pan or the like, the specification shall not be described foil or plastic container placed on the pan surface, should be described Pan surface not stacked items.
With a halogen lamp appliance, the user should be warned to avoid the specification look lit lamp.
If the label on the appliance GB/T 5465.2 (idt IEC 60417-1) a predetermined symbol 5021, which shall be described meaning.
For physical, sensory or mental defective or lacking experience and knowledge of people (including children), this description does not apply.
7.12.1 article replaced by the following.
The appliance shall be accompanied by instructions, special precautions necessary for installation details. For the plan to be combined with other appliances or fixed installation the appliance is installed on the wall should provide detailed requirements and protective measures to guard against electric shock and harmful ingress of water. As will be more than one control appliance Means for combining in a separate housing, the installation should provide detailed instructions. User maintenance, such as cleaning, etc., should also provide a description. Say Description specification the appliance should not be cleaned using the water jet.
With an appliance inlet and immersed in the washing water intended to implement, should be supplied instructions, must be removed before cleaning appliance connector Device, and before reuse, the input jack should be dried.
Non-Stationary with removable appliances and appliances such as electric component not intended to partially or fully immersed in water washing, the specification shall say Description of the equipment or components may not be flooded.
For permanently connected to the fixed wiring and leakage current may exceed 10mA appliance, especially long-term in an open state or stopped Use, or when first installed, the specification intended to provide protection on the installation (such as earth leakage protection relay) recommendation rating.
Compliance is checked by inspection.
7.12.4 Addition.
An independent control panel for a number of built-in appliances station apparatus to be used, it should be noted that instructions for use. The control panel can only be specified with Appliances connected to avoid possible danger.
7.15 Addition.
If the flag is not set so that a fixed appliance can be seen after installation, the corresponding information should be written into the instruction manual or is applied on the label, the label can be fixed in the vicinity of the installed appliance.
101 Note. Built-in appliances is an example of such fixed appliances.
Chapter 11 7.101 During the test, the test if the angle of the side walls and the rear wall temperature in pan surface exceeds the above 65K, and/or in the feed Chapter 19 when the line test, above or below the surface of the pan side walls, roof or floor temperature exceeds 125K, the installation instructions provided by the manufacturer should include the following points, this should also include the elements attached to the label, for example, temporary tying appliance type in.
Placed in close proximity to the appliance, such as walls, partitions, kitchen equipment, decorative panels, etc., these devices and facilities recommended non-combustible material, no it should be covered with a suitable non-combustible insulation material, and pay close attention to fire safety regulations.
Compliance is checked by inspection.
5021 7.102 predetermined symbol equipotential bonding terminal application GB/T 5465.2 (idt IEC 60417-1) indicated.
These signs should not be placed screws, removable washers or other member may be removed when the wire is connected.
Compliance is checked by inspection.
Immersed in the water going to the removable appliances or electrical components shall be marked flooding line, clearly marked when the maximum depth of immersion cleaning 7.103, Warning together with the following points.
Flooding Do not exceed this line.
If any seams or interfaces, or appliance components can not cause subjected to predetermined processing 15.102, when the member is in the cleaning appliance or GB 4706.37-2008/IEC 60335-2-38:2002 Position, the line should be submerged at least 50mm or less in such a seam or interface.
Compliance is checked by inspection and measurement.
8 Protection against access to live parts
This chapter in GB 4706.1-2005 is applicable.
9 Start electric appliances
GB 4706.1-2005 in this chapter except as follows, are applicable.
Voltage conditions all conform to 9.101 Chapter fan motor 11 for cooling requirements, should be possible in practical use start up.
Compliance is checked by starting the motor three times at 0.85 times rated voltage to check. Start the motor in the test room temperature.
Under each condition to start work are ready to start the motor, for automatic appliances, at the beginning of the normal operating cycle Under conditions, between two consecutive start, the motor can reach a stationary state. Centrifugal apparatus not equipped with a motor start switch when, at 1.06 times the rated voltage of the above test is repeated.
In all the above cases, the motor should be able to start, run and should not affect the safe way, overload protection devices shall not operate.
Note. During the test, the power supply voltage drop should not exceed 1%.
Power input and current 10 GB 4706.1-2005 in this chapter except as follows, are applicable.
10.1 Addition.
101 NOTE. For appliances having more than one heating element, the total input power may be determined by measuring the input power of each heating element (see 3.1.4).
11 Fever
GB 4706.1-2005 in this chapter except as follows, are applicable.
11.2 Addition.
And the fixing device is greater than the mass on the floor without 40kg roller assembly, the appliance castors or the like, in accordance with the manufacturer's instructions Installation. If you do not provide a description, I think that these instruments are usually placed on the floor use.
11.4 article replaced by the following.
The appliance is operated under normal operating conditions, so that the total input power is 1.15 times the rated input power. If not simultaneously turned ON A heating element, each composition is tested under conditions that allow the configuration of the switch, and the circuit configuration is consistent with the presence of each of the switches the highest possible load.
If any of the appliance with the controller to limit the total input power, the controller may select this test can be applied to the most severe conditions One kind of electric heating elements to composition.
If the temperature rise of the motor, a transformer or an electronic circuit exceeds a limit value, the test is repeated at the appliance 1.06 times the rated voltage. in in this case, only temperature measurements of motors, transformers or electronic circuits.
11.7 article replaced by the following.
The appliance work continuously until steady conditions are established.
101 Note. The test duration should include more than one working cycle.
11.8 Addition.
For the test angle back and side walls, comprising a projecting part in front of the appliance, the temperature rise of 65K limits apply only to the height of the pan surface.
As the height exceeds the above temperature limit, 7.101 apply.
GB 4706.37-2008/IEC 60335-2-38:2002
12 Void
Leakage current and electric strength at the operating temperature of 13 GB 4706.1-2005 in this chapter except as follows, are applicable.
13.2 article would make the following amendments.
Instead of class I stationary appliances with the following variation allowable leakage current value.
--- cord and plug for connecting the appliance. app...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
Referenced standards
Normative references
GB 4706.1-2005 · IEC 60335
How to Download GB 4706.37-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4706.100-2009 — Household and similar electrical appliances - Safety - Particular requirements for multifunctional shower room
GB 4706.101-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for drives for rolling shutters, awnings, blinds and similar equipment
GB 4706.104-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for heated gullies for roof drainage
Secure payment via Stripe
Payments accepted
GB 4706.37-2008
$125.00