Valid

GB 28147-2011Pyridaben wettable powders (English PDF)

哒螨灵可湿性粉剂

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GB 28147-2011 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Mandatory

Issue date

December 30, 2011

Implementation date

April 15, 2012

Scope

GB 28147-2011 is the English-translated version of 哒螨灵可湿性粉剂.

GB 28147-2011 — This standard specifies pyridaben WP requirements, test methods and marking, labeling, packaging, storage and warranty. This standard applies to processed from pyridaben the original drug, suitable additives and fillers made of pyridaben WP.

Note. Other name, structural formula and basic physicochemical parameters pyridaben see Appendix A.

Found what you need?

Document preview — GB 28147-2011

National Standard of the People's Republic of China

ICS
65.100.10
Classification
G 25

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Requirements
  • 3.1 Composition and appearance
  • 3.2 Technical Specifications
  • 4.1 General provisions
  • 4.2 Sampling
  • 4.3 Identification Test
  • 4.4 Determination of the mass fraction of pyridaben
  • 4.6 Determination of the suspension rate
  • 4.7 Determination of wetting time
  • 4.8 Determination of fineness
  • 4.9 Thermal storage stability test
  • 4.10 Product inspection and acceptance
  • 5 Marking, labeling, packaging, storage, security, guarantee
  • 5.1 Marking, labeling, packaging
  • 5.2 Storage
  • 5.3 Security
  • 5.4 Warranty Period

Foreword

The standard Chapter 3, Chapter 5 is mandatory, the rest are recommended.

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

Please note that some content of this document may involve patents, the issuing authority of this document does not assume responsibility for the identification of these patents.

The standard proposed by China Petroleum and Chemical Industry Association.

This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized.

1 Scope

This standard specifies pyridaben WP requirements, test methods and marking, labeling, packaging, storage and warranty.

This standard applies to processed from pyridaben the original drug, suitable additives and fillers made of pyridaben WP.

Note. Other name, structural formula and basic physicochemical parameters pyridaben see Appendix A.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

Determination of GB/T 1601 Pesticides pH value GB/T 1604 Goods pesticide regulations for acceptance GB/T 1605-2001 Sampling Method commercial pesticides GB 3796 pesticide packaging General GB/T 5451 WP Pesticide wettability measurement method GB/T 6682-2008 analytical laboratory use specifications and test methods (ISO 3696. 1987, MOD) GB/T 8170-2008 revised value represents about rules and limit values and judgment GB/T 14825-2006 Method for determination of pesticide suspension GB/T 16150 pesticide powder, wettable powder fineness measurement method GB/T 19136 Determination of Pesticide Thermal storage stability

3 Requirements

3.1 Composition and appearance

This product should be compliant pyridaben the original drug with suitable additives and fillers processing is made uniform loose powder, there should be no lumps.

3.2 Technical Specifications

Pyridaben WP should meet the requirements of Table 1.

Table 1 pyridaben WP Control Project Index

project

index

20% 30%

Pyridaben mass fraction /% 20.0 30.0 1.5-1.5 1.2-1.2 pH range of 5.0 to 9.0 Suspension rate /% >= 75 Wetting time/s <= 90

Table 1 (continued)

project

index

20% 30%

Fineness (through 44µm test sieve) /% >= 96 Thermal storage stability test a qualified when a normal production, heat storage stability test was measured at least once every three months.

Test Method 4

Safety Tips. Use of this standard shall have practical experience of laboratory personnel work. This standard does not point out all of the safety issues. Make with those who have the responsibility to take appropriate safety and health practices and to ensure compliance with the relevant national regulations.

4.1 General provisions

This standard reagents and water in the absence of other requirements specified, refers to three analytical reagent and GB/T 6682-2008 specified in water. Test results determined in accordance with GB/T 8170-2008 4.3.3 The "rounding value comparison method".

4.2 Sampling

According to GB/T 1605-2001 "on solid preparation sampling" approach. Determining sample package using a random number table method; the final sample size not less than 300g.

4.3 Identification Test

Gas Chromatography --- The identification test can be carried out simultaneously with the determination of the mass fraction of pyridaben. Under the same chromatographic operating conditions, the test A sample solution peak retention time compared with standard sample solution PYRIDABEN chromatographic retention time, the relative difference should be less than 1.5%.

Liquid chromatography --- The identification test can be carried out simultaneously with the determination of the mass fraction of pyridaben. Under the same chromatographic operating conditions, the test A sample solution peak retention time compared with standard sample solution PYRIDABEN chromatographic retention time, the relative difference should be less than 1.5%.

4.4 Determination of the mass fraction of pyridaben

4.4.1 High performance liquid chromatography (Arbitration Act)
4.4.1.1 Method summary

Sample was dissolved in methanol, acetonitrile and water as the mobile phase, use as filler in Nova-PakC18 stainless steel column and UV detector (240nm), the sample of PYRIDABEN high performance liquid chromatography and determination.

4.4.1.2 Reagents and solutions

Methanol;

Acetonitrile. chromatographic pure;

Water. The new secondary steam distilled water;

Pyridaben Sample. Known pyridaben mass fraction w>=99.0%.

4.4.1.3 Instruments

High performance liquid chromatography. a variable wavelength UV detector;

Chromatographic data processor or workstation;

Column. 150mm × 3.9mm (id) stainless steel column, built-Nova-PakC18,5µm filler (or equivalent effect Chromatography column);

Filter. pore size of about 0.45µm;

Micro injector. 50µL;

Quantitative sample line. 5µL;

Ultrasonic cleaner.

4.4.1.4 HPLC operating conditions

Mobile phase. Psi (CH3CN.H2O) = 85.15;

Flow rate. 1.0mL/min;

Column temperature. room temperature (temperature change should not exceed 2 °C);

Detection wavelength. 240nm;

Injection volume. 5µL;

Retention time. pyridaben about 5.6min.

It said operating parameters are typical, according to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results.

Typical pyridaben WP HPLC is shown in Figure 1.

1 --- pyridaben.

Figure 1 pyridaben WP High Performance Liquid Chromatographic

4.4.1.5 Measurement procedure
4.4.1.5.1 Preparation of standard solution

Weigh 0.1g PYRIDABEN standard (accurate to 0.0002g), a 50mL volumetric flask, dilute to the mark with methanol, ultrasonic oscillation 5min make sample dissolution, cooled to room temperature and shake well. Using a pipette to take the above solution 5mL to 50mL volumetric flask, diluted with methanol to the mark.

4.4.1.5.2 Preparation of sample solution

Weigh containing pyridaben 0.1g sample (accurate to 0.0002g), a 50mL volumetric flask, dilute to the mark with methanol, ultrasonic Oscillation 5min make sample dissolution, cooled to room temperature and shake well. Using a pipette to take the above solution 5mL to 50mL volumetric flask with methanol Dilute to the mark.

4.4.1.5.3 Determination

Under these operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles PYRIDABEN Lingfeng area relative change After less than 1.2%, according to the solution, the sample solution, the sample solution and standard sequence of the standard solution was measured.

4.4.1.6 Calculation

The two needle sample solution and measured before and after the two doses of the standard sample solution PYRIDABEN Lingfeng area were averaged. Sample PYRIDABEN the mass fraction according to equation (1).

w1 = A2

· M1 · w

A1 · m2

Where.

w1 --- sample pyridaben mass fraction, expressed as a percentage;

A2 --- sample solution, pyridaben mean Lingfeng area;

m1 --- pyridaben standard mass in grams (g);

w --- pyridaben standard mass fraction, expressed as a percentage;

A1 --- standard solution, pyridaben mean Lingfeng area;

m2 --- sample mass, in grams (g).

4.4.1.7 Allowable difference

Difference pyridaben mass fraction of two parallel determination results shall not be greater than 0.5%, the arithmetic mean value as a measurement result.

4.4.2 Capillary Gas Chromatography
4.4.2.1 Method summary

Sample was dissolved in chloroform, dicyclohexyl phthalate esters as internal standard, using a DB-1701 capillary column coated walls, and hydrogen Flame ionization detector, sample the PYRIDABEN capillary gas chromatography and determination.

4.4.2.2 Reagents and solutions

Chloroform;

Pyridaben standard. a known mass fraction w>=99.0%;

Dicyclohexyl phthalate ester. not interfere with the analysis of impurities;

Internal standard solution. Weigh 5.0g dicyclohexyl phthalate esters into 500mL volumetric flask, dissolved with chloroform, constant volume, Shake well.

4.4.2.3 Instruments

Gas chromatograph. with flame ionization detector;

Column. 30m × 0.32mm (id) quartz capillary column, wall coated with DB-1701, a film thickness of 0.25µm;

Chromatographic data processor or chromatography workstation.

4.4.2.4 GC operating conditions

Temperature (°C). Room 240 column, the gasification chamber 270, detection chamber 280;

Gas flow rate (mL/min). carrier gas (N2) 1.8, hydrogen gas 30, air 300, the compensation gas 25;

Split ratio. 40.1;

Injection volume. 2.0µL;

Retention time. pyridaben about 8.2min, internal standard about 5.0min.

GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. A typical gas chromatogram pyridaben WP and the internal standard is shown in Figure 2.

1 --- internal standard;

2 --- pyridaben.

Figure 2 PYRIDABEN wettable powder with a gas chromatograph internal standard

4.4.2.5 Measurement procedure
4.4.2.5.1 Preparation of standard solution

Weigh pyridaben standard 0.05g (accurate to 0.0002g), placed in a glass bottle stuffed with a pipette 5mL internal standard solution, Shake well.

4.4.2.5.2 Preparation of the sample solution

Weigh containing pyridaben 0.05g sample (accurate to 0.0002g), placed in a glass bottle stopper, with the use and 4.4.2.5.1 with a pipette internal standard solution 5mL, shake.

4.4.2.5.3 Determination

Under the above chromatographic operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles pyridaben and the internal standard After the change of the relative peak area ratio of less than 1.5%, according to the solution, the sample solution, the sample solution and standard sequence analysis of the standard solution Determination.

4.4.2.6 Calculation

The two needle sample solution and measured before and after the two doses of the standard sample solution PYRIDABEN and the internal standard peak area ratios are averaged.

Sample PYRIDABEN content according to formula (1 ') Calculated.

w'1 = r2 × m1 × wr1 × m2 (1') where.

w'1 --- sample PYRIDABEN mass fraction, expressed as a percentage;

r2 --- the average of the sample solution PYRIDABEN and the internal standard peak area ratio;

m1 --- standard mass in grams (g);

w --- standard samples pyridaben mass fraction, expressed as a percentage;

Mites and the average internal standard peak area ratio r1 --- standard solution clatter;

m2 --- sample mass, in grams (g).

4.4.2.7 Allowable difference

The difference between two parallel determination results shall not be greater than 0.5%, the arithmetic mean value as a measurement result.

Determination of 4.5 pH value According to GB/T 1601 carried out.

4.6 Determination of the suspension rate

4.6.1 Liquid Chromatography

According to GB/T 14825-2006 of 4.2. Weigh containing pyridaben 0.2g sample (accurate to 0.0002g), the bottom of the cylinder 25mL suspension is fully transferred to 100mL volumetric flask with methanol solution to the mark, in the ultrasonic oscillating 3min, standing, too After filtration, measured by mass 4.4.1 pyridaben calculate the suspension rate.

4.6.2 Gas Chromatography

According to GB/T 14825-2006 of 4.2. Weigh containing pyridaben 0.2g sample (accurate to 0.0002g), the bottom of the cylinder 25mL suspension is fully transferred to 100mL beaker, and water and drying in an oven at 105 °C. And 4.4.2.5.1 with the same use Branch pipette accurately added internal standard solution 5mL, ultrasonic oscillation under 3min, to stand. 4.4.2 Determination of mass pyridaben calculate the Suspension rate.

4.7 Determination of wetting time

According to GB/T 5451 carried out.

4.8 Determination of fineness

According to GB/T 16150 in the "wet sieve method".

4.9 Thermal storage stability test

According to GB/T 19136 in "powder formulations" to. After PYRIDABEN thermal storage mass fraction should not be less than the reservoir before pyridaben mass fraction 97% suspension rate should meet the standard requirements.

4.10 Product inspection and acceptance

Shall comply with GB/T 1604's.

5 Marking, labeling, packaging, storage, security, guarantee

5.1 Marking, labeling, packaging

Pyridaben WP signs, labeling and packaging should comply with the provisions of GB 3796; pyridaben WP use aluminum foil bag package Loading. Carton net content not exceeding 10kg. Also available upon request or order agreement, the use of other forms of packaging, subject to the provisions of GB 3796.

5.2 Storage

Pyridaben WP package should be stored in ventilated, dry warehouse; storage and transportation to prevent moisture and sun, not with food, seed Child, feed-mixing, avoid contact with skin, eyes, mouth and nose to prevent inhalation.

5.3 Security

This product is moderately toxic mites, pesticides, are swallowed and inhaled toxic, can penetrate through the skin. Wear protective goggles and rubber the FDA Leather gloves to wear the necessary protective clothing. After application, immediately wash with soap and water. Such as skin, eyes accidentally stained the product immediately with large the amount of rinse. Coverage should be immediately sent to hospital symptomatic treatment.

5.4 Warranty Period

Under the provisions of storage and transportation conditions, the guarantee period pyridaben WP from the date of manufacture of two years.

Appendix A

(Informative)

Pyridaben other name, structural formula and basic physicochemical parameters this product is an active ingredient pyridaben other name, structural formula and basic physicochemical parameters are as follows.

ISO common name. Pyridaben CAS Registry Number. 96489-71-3 CIPAC Numeric Code. 583 Chemical name. 2-tert-butyl-5- (4-tert-butyl-benzyl) -4-chloro -3 (2H) - pyridazinone Structure.

Empirical formula. C19H25ClN2OS Molecular Weight. 364.9 Biological activity. acaricidal, insecticidal Melting point. about 111 °C ~ 112 °C Vapor Pressure.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download GB 28147-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 28147-2011

$165.00