Valid

GB 23553-2009Prometryn wettable powders (English PDF)

扑草净可湿性粉剂

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GB 23553-2009 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Mandatory

Issue date

April 27, 2009

Implementation date

November 1, 2009

Scope

GB 23553-2009 is the English-translated version of 扑草净可湿性粉剂.

GB 23553-2009 — This standard specifies the Prometryne WP requirements, test methods and marking, labeling, packaging, storage and transportation. This standard applies to the Prometryne original drug, suitable additives and fillers processed Prometryne WP.

Found what you need?

Document preview — GB 23553-2009

National Standard of the People's Republic of China

ICS
65.100.20
Classification
G 25

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Requirements
  • 3.1 Composition and appearance
  • 3.2 Technical Specifications
  • 4.1 Sampling
  • 4.2 Identification Test
  • 4.3 Determination of the mass fraction of Prometryne
  • 4.4 Determination of Moisture
  • 4.6 Determination of the suspension rate
  • 4.7 Determination of wetting time
  • 4.8 Determination of fineness
  • 4.9 Thermal storage stability test
  • 4.10 Product inspection and acceptance
  • 5 Marking, labeling, packaging, storage and transportation

Foreword

The standard Chapter 3, Chapter 5 are mandatory, the rest are recommended.

Appendix A of this standard is the data appendix.

Since the implementation of this standard, the original industry standard HG2202-1991 "Prometryne WP" void.

The standard proposed by China Petroleum and Chemical Industry Association.

This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized.

1 Scope

This standard specifies the Prometryne WP requirements, test methods and marking, labeling, packaging, storage and transportation.

This standard applies to the Prometryne original drug, suitable additives and fillers processed Prometryne WP.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 1600 Determination of Water Pesticides Determination of GB/T 1601 Pesticides pH value GB/T 1604 Goods pesticide regulations for acceptance GB/T 1605-2001 Sampling Method commercial pesticides GB 3796 pesticide packaging General GB/T 5451 WP Pesticide wettability measurement method GB/T 14825-2006 Method for determination of pesticide suspension GB/T 16150 pesticide powder, wettable powder fineness measurement method GB/T 19136 Determination of Pesticide Thermal storage stability

3 Requirements

3.1 Composition and appearance

This product should be compliant Prometryne original drug with suitable additives and fillers processing is made uniform loose powder, there should be no lumps.

3.2 Technical Specifications

Prometryne WP should meet the requirements of Table 1.

Table 1 Prometryne WP Quality Control Project Index

project

index

50% 40% 25%

Prometryne mass fraction /% 50.0 + 40.0 + 2.0-2.0 2.5-2.5 1.5-1.5 25.0 + Moisture /% <= 3.0 pH range 6.0 to 10.0 Suspension rate /% >= 70 Wetting time/s <= 120 Fineness (through 45µm test sieve) /% >= 98 Thermal storage stability test a qualified when a normal production, heat storage stability test was measured at least once every three months.

Test Method 4

4.1 Sampling

According to GB/T 1605-2001 "on solid preparation sampling" approach. Determining sample package using a random number table method; the final sample size not less than 300g.

4.2 Identification Test

Gas Chromatography --- The identification test can be carried out simultaneously with the determination of the mass fraction of Prometryne. Under the same chromatographic operating conditions, the test A sample solution peak retention time with the standard solution flutter grass net retention time in peaks, the relative difference should be 1.5% Fewer.

4.3 Determination of the mass fraction of Prometryne

4.3.1 Method summary

Sample was dissolved in chloroform to triadimefon as internal standard, the use of the inner wall of the bonded Carbowax 20M capillary column and flame Ionization detector to sample Prometryne gas chromatographic separation and determination. You can also use packed column gas chromatography, chromatographic conditions Senate See Appendix A.

4.3.2 Reagents and solutions

Chloroform;

Triadimefon. should not interfere with the analysis of impurities, >=95%;

Prometryne Sample. Known Prometryne mass fraction >=99.0%;

Internal standard solution. Weigh 8.6g triadimefon, placed 1000mL volumetric flask with chloroform to dissolve and dilute to volume, shake.

4.3.3 Instruments

Gas chromatograph. with a hydrogen flame ionization detector;

Chromatographic data processor or chromatography workstation;

Column. 30m × 0.32mm (. I.d) capillary column, wall-bonded polyethylene glycol 20M, film thickness 0.25µm;

Micro injector. 10µL.

4.3.4 GC operating conditions

Temperature (°C) Temperature. 195 gasification chamber. 230, detection chamber. 230;

Gas flow rate (mL/min). carrier gas (N2) 2.0, hydrogen gas 30, air 300;

Injection volume (µL). 1.0;

Retention time (min). Prometryne about 4.2, internal standard (triadimefon) about 5.6.

GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. Typical Prometryne wettable powder with a gas chromatograph internal standard is shown in Figure 1.

1 --- Prometryne;

2 --- internal standard (triadimefon).

Figure 1 Prometryne WP and the internal standard gas chromatograph

4.3.5 Measuring step
4.3.5.1 Preparation of standard solution

Weigh Prometryne standard 0.1g (accurate to 0.0002g), placed in 15mL stoppered glass bottle with a pipette moved 10mL internal standard Solution, shake.

4.3.5.2 Preparation of the sample solution

It weighs about 0.1g sample containing Prometryne of (accurate to 0.0002g), placed in 15mL stoppered glass bottle, in use with 4.3.5.1 with a pipetted into internal standard solution 10mL, shake.

4.3.5.3 Determination

Under these operating conditions, the instrument until a stable baseline, the number of continuous injection doses of the standard solution, calculated for each needle Prometryne and the internal standard peak area Repeatability ratio, when two needles Prometryne relative change compared with the internal standard peak area of less than 1.2%, according to the standard solution, sample to be adjacent Solution, sample solution, the order of the standard solution was measured.

4.3.6 Calculation

The two needle sample solution and measured before and after the two doses of the standard sample solution Prometryne and the internal standard peak area ratio in the average respectively.

Prometryne sample mass fraction of 1 (%), according to equation (1).

Where.

--- Prometryne standard mass fraction, expressed as a percentage.

4.3.7 Allowable difference

The difference between two parallel determination results, 25% should be no more than 0.5%, 50% and 40% should not exceed 1.0%, respectively, and the arithmetic mean as a measurement result.

4.4 Determination of Moisture

According to GB/T 1600 in the "azeotropic distillation method".

According to GB/T 1601 carried out.

4.6 Determination of the suspension rate

Weigh 0.4g sample containing Prometryne of (accurate to 0.0002g), according to GB/T 14825-2006 4.1 performed. The cylinder bottom 25mL suspension and precipitate in a water bath to dryness, and then returned to room temperature measured by the mass fraction of 4.3 Prometryne calculate the suspension rate.

4.7 Determination of wetting time

According to GB/T 5451 carried out.

4.8 Determination of fineness

According to GB/T 16150 in the "wet sieve method".

4.9 Thermal storage stability test

According to GB/T 19136 in "powder formulations" to. After the heat storage Prometryne content should not be less than the reservoir Qianpu grass net mass fraction 97% suspension rate should meet the standard requirements.

4.10 Product inspection and acceptance

Product inspection and acceptance shall comply with GB/T 1604's. Treatment of extreme values using the rounding value comparison method.

5 Marking, labeling, packaging, storage and transportation

WP 5.1 Prometryne signs, labeling and packaging should comply with the provisions of GB 3796.

WP 5.2 Prometryne aluminum foil bag or plastic bag, net weight of 100g, 200g, 250g, 500g; packaging can Cartons, corrugated cardboard box or Plastic boxes each containing a net content not exceeding 20kg. Also available upon request or order agreement, the use of other forms of Type of packaging, subject to the provisions of GB 3796.

5.3 Prometryne WP package should be stored in well-ventilated, dry coffers.

5.4 storage, prevent moisture and sunlight, no food, seed, feed mix, avoid contact with skin, eyes, mouth and nose to prevent inhalation.

5.5 Security. Prometryne low toxicity herbicides. The FDA should wear protective gloves. Nose and mouth to prevent inhalation, or skin contact with exposed parts of the body the goods should be promptly washed with soap and water. In case of poisoning should promptly consult a doctor.

5.6 Warranty. under the specified storage conditions Prometryne guarantee wettable powder, from date of manufacture for 2 years.

Appendix A

(Informative)

Prometryne content packed column gas chromatographic method A. 1 Method summary Sample was dissolved in chloroform to triadimefon as internal standard, using polyethylene glycol 20M/GasChromQ packed column and flame Ionization detector to sample Prometryne gas chromatographic separation and determination.

A. 2 Reagents and solutions Chloroform;

Triadimefon. should not interfere with the analysis of impurities, >=95%;

Prometryne Sample. Known Prometryne mass fraction >=99.0%;

Internal standard solution. Weigh 10.0g of triadimefon, placed 1000mL volumetric flask with chloroform to dissolve and dilute to volume, shake.

A. 3 Instrument

Gas chromatograph. with a hydrogen flame ionization detector;

Chromatographic data processor or chromatography workstation;

Column. 3% polyethylene glycol 20M/GasChromQ (80 mesh to 100 mesh) stainless steel column (column or glass);

Micro injector. 10µL.

A. 4 GC operating conditions Temperature (°C).200 Column temperature gasification chamber 230, the detector chamber 230;

Gas flow rate (mL/min). carrier gas (N2) 80, hydrogen gas 40, air 400;

Injection volume (µL). 1.0;

Retention time (min). Prometryne about 5.2, about 7.0 internal standard.

GC operating conditions described above, the Department of typical operating parameters. According to the characteristics of different instruments, given operating parameters adjusted as appropriate, in order to obtain the best results. Typical Prometryne original drug and the internal standard packed column gas chromatography is shown in Figure A. 1.

1 --- Prometryne;

2 --- internal standard (triadimefon).

Figure A. 1 Prometryne WP and the internal standard packed column gas chromatogram

A. 5 measuring step

A. 5.1 preparation of standard solution Weigh Prometryne standard 0.1g (accurate to 0.0002g), placed in 15mL stoppered glass bottle with a pipette accurately transferred to 10mL Internal standard solution, and shake.

A. 5.2 Sample preparation solution it weighs about 0.1g sample containing Prometryne of (accurate to 0.0002g), placed in 15mL stoppered glass vial, with A. 5.1 used with a pipette accurately transferred to the internal standard solution 10mL, shake.

A. 5.3 Determination Under these operating conditions, the instrument until a stable baseline, the number of continuous injection doses of the standard solution, calculated for each needle Prometryne and the internal standard peak area Repeatability ratio, when two needles Prometryne relative change compared with the internal standard peak area of less than 1.2%, according to the standard solution, sample to be adjacent Solution, sample solution, the order of the standard solution was measured.

A. 6 Calculation

The two needle sample solution and measured before and after the two doses of the standard sample solution Prometryne and the internal standard peak area ratios are averaged.

Flutter grass net sample mass fraction of 1 (%) according to equation (A.1) Calculated.

Where.

--- Prometryne standard mass fraction, expressed as a percentage.

A. 7 allowable difference the difference between two parallel determination results, 25% should be no more than 0.5%, 50% and 40% should not exceed 1.0%, respectively, and the arithmetic mean as a measurement result.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download GB 23553-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 23553-2009

$155.00