Valid

GB 20840.2-2014Instrument transformers -- Part 2: Additional requirements for current transformers (English PDF)

互感器 第2部分:电流互感器的补充技术要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (56 pages)

Need quotation for your management?

Get a formal quotation for GB 20840.2-2014 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Mandatory

Issue date

September 3, 2014

Implementation date

August 3, 2015

Scope

GB 20840.2-2014 is the English-translated version of 互感器 第2部分:电流互感器的补充技术要求.

GB 20840.2-2014 — GB 20840 for this section applies to electrical measuring instruments and/or electrical protection devices use a frequency of 15Hz ~ 100Hz new Manufacture of electromagnetic current transformer.

Found what you need?

Document preview — GB 20840.2-2014

National Standard of the People's Republic of China

ICS
290.18
Classification
K 41
Replacing
GB 1208-2006; GB 16847-1997

Issued by: Standardization Administration of China

Contents

  • Introduction
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 General definitions
  • About 3.3 Current Rating Definition
  • 3.4 Concerning the definition of the accuracy of
  • 3.7 Symbol and name
  • 5 11 ratings

Foreword

This section on recommended and mandatory provisions of the regulations and GB 20840.1-2010 "transformers - Part 1. General technical requirements" the same.

GB 20840 "transformer" intends divided into the following sections.

--- Part 1. Common technical requirements;

--- Part 2. additional technical requirements current transformer;

--- Part 3. Supplementary technical requirements of electromagnetic voltage transformer;

--- Part 4. Combined Transformer additional technical requirements;

--- Part 5. additional technical requirements for capacitor voltage transformer;

--- Part 6. electronic transformer and low power independent of the sensor complement common technical requirements;

--- Part 7. Electronic voltage transformers supplementary technical requirements;

--- Part 8. Electronic current transformers additional technical requirements;

--- Part 9. Transformer digital interface;

--- Part 10. Supplementary independent current sensor technology low power requirements;

--- Part 11. Low-power complementary technologies independent voltage sensor requirements;

--- Part 12. Combined electronic transformer and complementary combination of technical requirements independent of the sensor;

--- Part 13. Independent merge cells.

This is Part 2 GB 20840's.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This Part replaces GB 1208-2006 "CT" and GB 16847-1997 "to protect the current transformers for transient performance begging".

This section needs with GB 20840.1-2010 "transformers - Part 1. General technical requirements" supporting the use of. This section follows the GB 20840.1 of the preparation of the structure, is a supplement corresponding provisions of GB 20840.1, modification or replacement. When the terms of GB 20840.1 In this Part not to mention the points in time, as long as reasonable, those terms would apply to this section. When specified in this section, "Added" when "modification" or "replacement", it means that the relevant provisions of GB 20840.1 in this section is adapted accordingly.

For Zhang, bars, graphs, tables, notes and appendix in GB 20840.1-2010 based on additions, this section uses the following forms of ID.

--- Chapter, article, figures, tables and notes are numbered from 201 starts;

--- Appendix No. 2A, 2B and the like.

This section uses redrafted law revision using IEC 61869-2:2012 "Transformers Part 2. complementary technologies to current transformer begging".

This part of IEC 61869-2:2012, compared with more adjustment in the structure, are listed in the Appendix 2A of this section with IEC 61869-2.

Chapter, article, figure, table number 2012 of the control list.

Technical differences exist compared to 2012, the terms of these differences have been involved through gaps in its outer margin. This part of IEC 61869-2 A single vertical line at position (|) have been identified in Appendix 2B are given a list of corresponding technical differences and their causes.

This section also made the following editorial changes.

--- Increasing the "Introduction";

--- The full text of the unified formula is numbered;

--- 3.4.3 and in the note of the contents of the text would read 3.4.203;

--- To rationalize the provisions with later echoed the IEC standard 5.6.201.2 of general purpose and special purpose standard current transformer Quasi accuracy classes are predetermined;

--- 207 for table of contents made editorial adjustments;

--- Order the Appendix to re adjusted;

--- To IEC standard Figure 2B.13 and 2E.1 been adjusted.

Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.

This part is proposed by the China Electrical Equipment Industrial Association.

This part of the National Standardization Technical Committee transformers (SAC/TC222) centralized.

This section is drafted. Shenyang Transformer Research Institute Co., Ltd., State Grid Electric Power Research Institute, Dalian first transformer limited liability any company, TBEA Kangjia (Shenyang) Transformer Co., Ltd., Dalian Northern Transformer Group Co., Ltd., Zhongshan City, Thailand-Electric have Limited, Jiangxi Power Electric Co., Ltd., Jiang Su Kexing Electric Co., Ltd., Dalian Transformer Co., Ltd., New Northeast Electric (Shenyang) High Voltage Switchgear Co., Ltd. Jingjiang, Jiangsu Transformer Co., Ltd., Baoding Tianwei Transformer Co., Ltd., Shenyang Transformer limited liability company.

Introduction

IEC/TC38 standard system has been realigned, before the upcoming IEC 60044 series of standards is now readjusted IEC 61869 series of standards. In order to better use of international standards, the National Standardization Technical Committee transformers (SAC/TC222) The study Decided to our current system of national standards Transformer also press IEC/TC38 new standard system be realigned before the upcoming the individual transformers to national standards IEC 60044 series of standards by the corresponding relationship between IEC 61869 series of standards correspond to re Develop, constitute a "common technical requirements" general part and each "Supplementary technical requirements" section dedicated supporting new Transformers series Country standard.

New national standards for transformers intended to form the overall situation is as follows.

General part of the standard number and name Special section Standard Dedicated part of the standard name corresponding Original Standard GB 20840.1 General technical requirements GB 20840.6 Electronic transformer and low Independent power sensor Supplementary general technical requirements GB 20840.2 GB 20840.3 GB 20840.4 GB/T 20840.5 GB 20840.7 GB 20840.8 GB 20840.9 GB 20840.10 GB 20840.11 GB 20840.12 GB 20840.13 Additional technical requirements for current transformers Supplementary technical requirements Electromagnetic Voltage Transformer Additional technical requirements Combined Transformer Additional technical requirements for capacitor voltage transformers Additional technical requirements for electronic voltage transformer Additional technical requirements for electronic current transformer Transformer Digital Interface Independent supplementary low power current sensor technology requirements Independent supplementary low power voltage sensor technology requirements A combination of electronic transformer and combinations of independent sensors Additional technical requirements Independent merging unit GB 1208 GB 16847 GB 1207 GB 17201 GB/T 4703 GB/T 20840.7 GB/T 20840.8 GB/T 20840.7 Transformers Part 2. Supplementary requirements for current transformer technology

1 Scope

GB 20840 for this section applies to electrical measuring instruments and/or electrical protection devices use a frequency of 15Hz ~ 100Hz new Manufacture of electromagnetic current transformer.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

Chapter 2 GB 20840.1-2010 content with the following additions apply.

GB/T 156 standard voltage (GB/T 156-2007, IEC 60038:2002, MOD) GB 311.1 insulation coordination - Part 1. Definitions, principles and rules (GB 311.1-2012, IEC 60071-1:2006, MOD) GB/T 3954 Electrical Pole GB/T 5585.1 electrician with copper, aluminum and its alloy bus - Part 1. Copper and copper alloy bus GB/T 7252 transformer oil dissolved gas analysis and judgment guidelines (GB/T 7252-2001, IEC 60599:1999, NEQ) Transformer oil quality GB/T 7595 running GB 20840.1-2010 transformers - Part 1. General Requirements (IEC 61869-1:2007, MOD)

3 Terms and Definitions

Terms and definitions defined in GB 20840.1-2010 and the following additions apply to this document.

3.1 General definitions

3.1.201

Current Transformer Under normal conditions, the secondary current is proportional to the primary current reality, and in the right way when the coupling phase difference close to zero Transformers.

[GB/T 2900.15-1997, the definition 3.4.5] 3.1.202 Measuring current transformer Information transfer current transformer signal for measuring instruments and meters.

[GB/T 2900.15-1997, the definition 3.4.8, modified] 3.1.203 Protective current transformer to protect and control means for transmitting information signals current transformer.

[GB/T 2900.15-1997, the definition 3.4.7, modified] 3.1.204 P-level protection current transformer classPprotectivecurrenttransformer no residual magnetic flux limit of protective current transformer, under the symmetrical short-circuit current conditions its provisions saturation characteristics.

3.1.205

PR level protection current transformer classPRprotectivecurrenttransformer Having a residual magnetic flux limit protection current transformers, short-circuit current in symmetrical conditions set its saturation characteristics.

3.1.206

PX-level protection current transformer classPXprotectivecurrenttransformer no residual magnetic flux leakage reactance low limit protective current transformer, which is known as the secondary excitation characteristic, secondary winding resistance, secondary load electricity Resistance and turns ratio, then it is sufficient to determine the associated protection system performance.

3.1.207

PXR-level protection current transformer classPXRprotectivecurrenttransformer Having a residual magnetic flux limit protection current transformer, which is known as excitation characteristics, the secondary winding resistance, secondary load resistance and turns ratio when, that is sufficient to determine the relay contact associated with their performance.

201 Note. When the current transformer primary current contains a DC component, the situation will be more complicated. Therefore, in order to prevent the current transformer into saturation, using Current transformer with an air gap, but the same performance level and PX.

202 Note. reduce remanence air gap does not necessarily become a high leakage reactance current transformers (see Appendix 2C).

3.1.208

TPX-level transient characteristics of protective current transformer classTPXprotectivecurrenttransformerfortransientper-formance no residual magnetic flux limit of protective current transformer, the peak instantaneous error in transient short-circuit current conditions its provisions saturation characteristics.

3.1.209

TPY-level transient characteristics of protective current transformer classTPYprotectivecurrenttransformerfortransientper-formance Having a residual magnetic flux limit protection current transformer, the peak instantaneous error in transient short-circuit current conditions its provisions saturation characteristics.

3.1.210

TPZ-level transient characteristics of protective current transformer classTPZprotectivecurrenttransformerfortransientper-formance the protection of a secondary time constant predetermined value of current transformers to the peak AC component of the error specified in the transient short-circuit currents its saturation characteristics.

3.1.211

Optional current transformer ratio selectable-ratiocurrenttransformer Using a winding line for access or access to a variety tapped secondary winding turns ratio of the current transformer.

About 3.3 Current Rating Definition 3.3.201 Rated primary current Ipr as the performance of the current transformer primary current reference value.

[GB/T 2900.15-1997, the definition 2.3.28] 3.3.202 Rated secondary current Isr as the current transformer secondary current value of performance benchmarks.

[GB/T 2900.15-1997, the definition 2.3.30] 3.3.203 Rated short-time thermal current Ith in the case of short-circuit the secondary winding of the current transformer can withstand without damage a current maximum root mean square value in a short time stipulated.

[GB/T 2900.15-1997, definitions 2.3.18, modified] 3.3.204 Rated dynamic current Idyn in the case of short-circuit the secondary winding of the current transformer can withstand the electromagnetic force without electrical or mechanical damage to the maximum primary current Peak.

[GB/T 2900.15-1997, the definition 2.3.20] 3.3.205 Rated continuous thermal current Icth in the secondary winding is connected with the rated load, allowing continuous flow through the primary winding and the temperature does not exceed a predetermined value of the current value.

[GB/T 2900.15-1997, definitions 2.3.19, modified] 3.3.206 Rated primary short-circuit current Ipsc A transient short-circuit current side AC component rms value of the reference current transformer accuracy performance.

Note 201. Ith limits associated with fever, Ipsc related to the accuracy limits, usually Ipsc less than Ith.

3.3.207

Excitation current excitingcurrent Ie when the primary winding and other windings open circuit current transformer nominal frequency sine wave voltage is applied to the second terminal of the secondary winding the current drawn by the root-mean-square value.

[GB/T 2900.15-1997, the definition 2.3.9, modified]

3.4 Concerning the definition of accuracy

3.4.3

The ratio difference ratioerror GB 20840.1-2010 3.4.3 and the following are applicable.

Current transformer ratio difference (current error) according to equation (1) expressed as a percentage.

epsilon =

krIs-Ip

× 100% (1)

Where.

kr --- rated transformation ratio;

Ip --- the actual primary current;

Is --- under the measurement conditions, the actual flow through the secondary current when Ip.

201 Note. the amount of interpretation phase is shown in Figure 2D.1.

3.4.4

Retardation phasedisplacement deltaphi GB 20840.1-2010 3.4.4 and the following are applicable.

201 Note. the amount of interpretation phase is shown in Figure 2D.1.

3.4.201

Rated resistive load ratedresistiveburden Rb Resistive load rating of the secondary connected in ohms (ohm).

3.4.202

Secondary winding resistance Rct Actual secondary winding DC resistance in ohms (ohm), corrected to 75 °C or other temperature as may be prescribed.

Note 201. Rct actual values. Not to be confused Rct upper limit, which can otherwise specified.

3.4.203

Composite error epsilonc at steady state, when a predetermined primary current and the secondary current in the positive direction of the terminal signs agreement following the difference between the root mean square value.

a) the instantaneous value of the primary current;

b) the instantaneous value of the actual secondary current multiplied by the rated transformation ratio.

Composite error epsilonc usually according to formula (2) percentage root mean square value of the primary current representation.

epsilonc =

Tintegral

(Kr × is-ip) 2dt

× 100% (2)

Where.

kr --- rated transformation ratio;

Ip --- primary current rms value;

ip --- primary current instantaneous value;

is --- secondary current instantaneous value;

T --- a cycle of time.

201 Note. See further explanation 2D.4.

[GB/T 2900.15-1997, definitions 2.3.17, modified] 3.4.204 Rated instrument limit primary current IPL Measuring current transformer secondary load equal to the rated load, the composite error is equal to or greater than the minimum primary current value at 10%.

3.4.205

Safety factor instrumentsecurityfactor FS Primary current and rated primary current ratio of rated instrument limit.

201 Note. It should be noted that the actual instrument security factor is the impact of the load. When the load is significantly lower than the nominal value, the short-circuit current in the secondary side will produce more High Current.

202 Note. If the system fault current through the current transformer primary winding, the rated instrument security factor FS is lower, by a transformer power supply means more safety.

[GB/T 2900.15-1997, definitions 2.3.22, modified] 3.4.206 to measure the second limit potential secondarylimitinge.mfformearsuringcurrenttransformers current transformer EFS Instrument security factor FS, rated secondary current and the rated load impedance of the secondary winding and the three vector product.

Note 201. Measuring current transformer secondary limit potential EFS according to equation (3) Calculated.

EFS = FS × Isr × (Rct Rb) 2 X2b (3) where.

Rb --- resistance portion of the rated load;

The reactance Xb --- rated load.

The resulting value is higher than the actual value of this method. So the choice is to use the same protective current transformer test methods. See 7.2.6.202 and 7.2.6.203.

[GB/T 2900.15-1997, definitions 2.3.25, modified] 3.4.207 Rated accuracy limit primary current Maximum current transformer primary current to meet the requirements of the composite error value.

[GB/T 2900.15-1997, the definition 2.3.23] 3.4.208 Accuracy limit factor ALF Rated accuracy limit primary current and rated primary current ratio of.

[GB/T 2900.15-1997, the definition 2.3.27] 3.4.209 Protective current transformer secondary limit potential secondarylimitinge.mfforprotectivecurrenttransformers EALF Accuracy limit factor, rated secondary current and the rated load impedance of the secondary winding and the three vector product.

Note 201. P and PR potential EALF level protection according to formula (4) with a current transformer secondary limit calculated as follows.

EALF = ALF × Isr × (Rct Rb) 2 X2b (4) where.

Rb --- resistance portion of the rated load;

The reactance Xb --- rated load.

3.4.210

Saturation flux Psisat the maximum value of the current transformer secondary turns the flux linkage, corresponding to a magnetic saturation of the core material.

201 Note. saturation flux Psisat determine the most appropriate method is 2E.2.3 in the DC saturation method.

202 Note. In previous GB 16847 in, Psis defined as the inflection point value, it is characterized by a non-core saturation to saturation changes. This definition because the saturation value Too low to be recognized, and cause misunderstandings and conflicts. Thus, the replacement of Psisat, defined as complete saturation.

3.4.211

Residual magnetic flux remanentflux Psir After cutting the core excitation current 3min remaining turns of the secondary flux linkage value, the magnetizing current should be large enough to produce the saturation flux (Psisat).

3.4.212

Remanence factor KR the ratio of the residual magnetic flux and the saturation flux, expressed as a percentage.

3.4.213

Secondary circuit time constant secondarylooptimeconstant Ts Current transformer secondary circuit time constant value determined by the magnetizing inductance and leakage inductance sum (Ls) and the secondary loop resistance (Rs), According to equation (5) Calculated.

3.4.214

Excitation characteristics excitationcharacteristic when the current transformer primary winding and other windings open circuit, it is applied to the second terminal of the root mean square value of sinusoidal voltage and excitation current the relationship between the root mean square value, expressed as a curve or table column values. Coverage data should be sufficient to determine the value of the field from a low of 1.1 times until Abduction Point excitation characteristics of potential value.

3.4.215

Knee voltage kneepointvoltage Rated frequency sinusoidal voltage side of the current transformer when all other terminals are open, is applied to the second terminal of the root-mean-value increase the field current rms value increased by 50% plus 10%.

[GB/T 2900.15-1997, definitions 2.3.36, modified] 3.4.216 Inflection potential kneepointe.mf the field current rms value increased by 50% of current transformer rated frequency potential, the value increased 10%.

201 Note. the inflection point voltage can be applied to the current transformer secondary terminals, and the potential turning point can not be directly manipulated. Inflection point and the inflection point voltage potential can be considered the number Values are equal, because the impact of the secondary winding resistance voltage drop is small.

3.4.217

Rated inflection potential ratedkneepointe.mf Ek Inflection point lower limit electric potential.

201 Note. Rated knee-level potential inclusion PX and PXR-level protection technology specification for current transformer. According to equation (6) Calculated.

Ek = Kx × Rct R () b × Isr (6) 3.4.218 Rated turns ratio A turns ratio of the numerical value of the secondary turns provisions.

Example 1. 1/600 (1 turn represents a number of turns, the secondary turns is 600 turns).

Example 2. 2/600 (expressed as a number of turns 2 turns, the secondary turns is 600 turns).

201 Note. inclusion rated turns ratio PX and PXR grade-level protection with the technical specifications of the current transformer.

202 Note. Rated turns ratio and are rated transformation ratio is a secondary requirement. If comparing the two nominal ratio should be reciprocal.

3.4.219

Turns ratio error epsilont the actual turns ratio represents the difference between the nominal turns ratio, the...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 56 pages — is available in the English PDF.

Referenced standards

How to Download GB 20840.2-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
56 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 20840.2-2014

$785.00