GB 15631 covers the fire detectors that fall outside the ordinary smoke and heat categories: point-type infrared flame detectors, aspirating smoke detection systems, image-based detectors and carbon monoxide fire detectors. For each it sets the technical requirements and the sensitivity, then a common battery of environmental tests - temperature, humidity, corrosion, vibration, shock and electromagnetic immunity - followed by the inspection rules and marking, with normative annexes on the gas test apparatus and the sensors. It is replaced by GB 12791-2025 from 1 November 2026. Issued on 1 September 2008, in force since 1 May 2009, replacing GB 15631-1995. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the edition it replaces are taken from there. The clause text, the tables and the numeric limits are not reproduced on this page - they are in the document itself, which is delivered in full in English translation.

Document preview — GB 15631-2008

National Standard of the People's Republic of China

ICS
13.220.20
Classification
C 81
Replacing
GB 15631-1995

Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Length/d
  • 4 Normal monitoring state
  • 4.1 General requirements
  • 4.1.7 Climate Experiment
  • 4.1.8 Mechanical environmental testing
  • 4.3.2 Basic performance
  • 4.3.3 Response threshold
  • 5 Normal monitoring state
  • 6 Each discharge point 10 times Discharge Polarity Positive, Negative Interval/s >=
  • 8 Contact discharge (sample shell conductor and the coupling plate)
  • 9.8 Sweep rate/(oct/min)
  • 10 Acceleration/(m/s2)
  • 20 No power

Foreword

The fourth through seventh chapter of this standard is mandatory, the rest are recommended. This standard replaces GB 15631-1995 "point-type infrared flame detector performance requirements and test methods" and GB 15631-1995 phase Comparison of the main changes are as follows:

--- This standard adds aspirating smoke detectors, image-type fire detectors, fire point-type carbon monoxide in the technical requirements Probe request;

--- This standard uses the latest version of the EMC requirements, select the appropriate severity, ease of international standards. This standard Annex A, Annex B normative appendix. The standard proposed by the People's Republic of China Ministry of Public Security. This standard by the National Standardization Technical Committee of the Sixth Fire Technical Committee. This standard is drafted by: Ministry of Public Security Shenyang Fire Research Institute. Participated in the drafting of this standard. Anhui Fire Department, Xi'an Pok Hong Electronics Co., Ltd., Shenzhen given the security system Limited HKUST The legislation security technology limited liability company. The main drafters of this standard. Ding Hongjun, Qu Li, Dou Baodong, Guo Chunlei, Yuanhong Yong, Zhang Ying Cong, Zhang Xuejun, fees plunger. Wang Wenqing, Song Liwei, Mei Zhibin, Li Haitao, Li Ningning, Sun Shuang, Li Rui, Deng Lihong. This standard replaces the standards previously issued as follows:

--- GB 15631-1995. Special Fire Detectors

1 Scope

GB 15631 covers the fire detectors that fall outside the ordinary smoke and heat categories: point-type infrared flame detectors, aspirating smoke detection systems, image-based detectors and carbon monoxide fire detectors. For each it sets the technical requirements and the sensitivity, then a common battery of environmental tests - temperature, humidity, corrosion, vibration, shock and electromagnetic immunity - followed by the inspection rules and marking, with normative annexes on the gas test apparatus and the sensors. It is replaced by GB 12791-2025 from 1 November 2026. Issued on 1 September 2008, in force since 1 May 2009, replacing GB 15631-1995. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the edition it replaces are taken from there. The clause text, the tables and the numeric limits are not reproduced on this page - they are in the document itself, which is delivered in full in English translation.

This standard specifies the special fire detectors (hereinafter referred to as detectors) classification, technical requirements, test methods, inspection rules, signs and so Instruction manual. This standard applies to general industrial and civil buildings to install fire detectors special use. With a special installation for use in other environments Special fire detectors special requirements, except as otherwise provided by the special requirements of the relevant standards, should be the implementation of this standard.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB 4706.1-1998 household and similar electrical appliances - Part 1. General requirements (eqv IEC 335-1.1991)

GB 4715 point-type smoke detectors

GB 9969.1 Instructions General Industrial Products

GB 12978 fire electronic products inspection rules

GB 16838 fire electronic products environment test methods and severities Category 3

3.1 Special fire detector according to the detection principle can be divided into.

a) point infrared flame detector;

b) aspirating smoke detector;

c) image-type fire detectors;

d) Point-type fire detectors carbon monoxide.

3.2 Point-type fire detectors by use of carbon monoxide can be divided into.

3.3 aspirating smoke detector in response to its threshold range can be divided into.

c) sensitive type.

3 Length/d

21 No power Corrosion Test Temperature/°C 25 ±

4 Normal monitoring state

4.1.7.2 Durability Test Detectors should be able to withstand the test under Table 2 under the climate conditions, after the test shall meet the following requirements. When

a) after the tests returned to normal monitoring state, the detector should send out a fire alarm signal or fault signal;

b) After the test, the detector should be able to work properly; the response threshold point infrared flame detector and its response in conformance Test Compared to a threshold, ratio of the maximum response threshold value to the minimum response threshold value should not be greater than 1.3; aspirating smoke detectors and fire point type Carbon monoxide fire detector response threshold value of its response threshold value in the consistency test, compared with the maximum response threshold value Smaller than the response threshold value should not be greater than 1.6; the response threshold image type fire detector should meet the requirements of 4.4.1. Table 2 durability test climate conditions require Name of Test Test Parameters Test Conditions Operating status Constant heat (Durability Test Temperature/°C 40 ±

4.1 General requirements

4.1.1 Alarm acknowledgment lamp The detector should be confirmed with a red warning light. When a monitored area fire alarm parameters meet the conditions, the detector alarm confirmation light should point Bright and kept to be reset. Through light display detector alarm acknowledgment status of other work, the state should be displayed with the fire alarm state Ariake Significant difference. Removable detector alarm acknowledgment lamp can be mounted on the probe or the base. Confirmation light is lit in front of their office 6m, according to No more than 500lx environmental conditions, should be clearly visible.

4.1.2 Auxiliary equipment connection When the probe is connected to other auxiliary equipment (such as remote confirmation lights, control relays, etc.), and auxiliary equipment between open and shorted cable It should not affect the normal operation of the detector.

4.1.3 Factory setting Unless special measures (such as special tools or password) or seal damage, otherwise detector factory settings should not be changed.

4.1.4 responsiveness set the scene If the detector response performance can be provided on-site probe or control and indicating equipment connected thereto, should be satisfied with The following requirements.

a) When the manufacturer declares that all settings meet the requirements of this standard, the detector under conditions shall be set to meet this standard Requirements, and for the field should be set only by special tools, password, or separate probe and the base means to achieve;

b) When a manufacturer's declaration does not satisfy the requirements of this standard is set, this setting should only by special tools, means of achieving password, And relevant documents on the detector should be clearly marked or the settings do not meet the requirements of this standard.

4.1.5 prevent foreign objects invade performance The detector should be able to prevent the diameter of (1.3 ± 0.05) mm spherical objects intrusion detection chamber.

4.1.6 User's Guide Detectors should be the appropriate instructions in Chinese. Prospectus shall meet the requirements of

GB 9969.1, and consistent with the product performance.

4.1.7 Climate Experiment

4.1.7.1 Test run The detector should be able to withstand the test specified in Table 1 under the climate conditions. During the test and after the test shall meet the following requirements.

a) During the test, the detector should send out a fire alarm signal or fault signal;

b) After the test, the detector should be able to work properly; the response threshold point infrared flame detector and its response in conformance Test Compared to a threshold, ratio of the maximum response threshold value to the minimum response threshold value should not be greater than 1.3; aspirating smoke detectors and fire point type Carbon monoxide fire detector response threshold value of its response threshold value in the consistency test, compared with the maximum response threshold value Smaller than the response threshold value should not be greater than 1.6; the response threshold image type fire detector should meet the requirements of 4.4.1. Climate conditions in Table 1 running test requirements Name of Test Test Parameters Test Conditions Operating status High temperature (running) test Temperature/°C 55 ±

4.1.8 Mechanical environmental testing

4.1.8.1 Test run Detectors should be able to withstand the trials Table 3 under specified mechanical environmental conditions during the test and after the test probe shall meet the following Claim.

a) During the test, the detector should send out a fire alarm signal or fault signal;

b) After the test, the detector should not have mechanical damage and tighten loose parts;

c) After the test, the basic performance of the detector normal; the response threshold point infrared flame detector with its response threshold in conformance Test Compared to the value than the maximum response threshold value to the minimum response threshold value should not be greater than 1.3; aspirating smoke detector and a point type Carbon monoxide fire detector response threshold value of its response threshold value in the consistency test, compared to the maximum response threshold value to the minimum Than the response threshold value should not be greater than 1.6; the response threshold image type fire detector should meet the requirements of 4.4.1. Table

3 Operational Test mechanical environmental conditions Name of Test Test Parameters Test Conditions Operating status Vibration Test (Sine) (run) Frequency range/Hz 10 ~ 150 ~

4.3.2 Basic performance

4.3.2.1 failure alarm 150% of the suction pipe leaking detector and clogged, resulting in larger than normal inspiratory flow detector inspiratory flow to or less than the normal intake 50% of traffic should a fault signal in the 100s.

4.3.2.2 Fire alarm When a sampling probe in any hole to obtain fire smoke alarm parameters meet the conditions, issue a fire alarm signal in the 120s.

4.3.2.3 detection alarm detectors special performance 4.3.2.3.1 Fire alarm The detector should be able to issue a fire alarm sound and light signal indicating the fire area, fire alarm recording time (of day clock timing detector Error should not exceed 30s), and be maintained until reset; alarm signal should be manually removed. For a number of road fire alarm function Probe Detector, when a new fire occurs, should be able to issue a fire alarm sound and light signal again. Fire alarm signal fault alarm signal shall take precedence. 4.3.2.3.2 failure alarm Between the detector and its connected components when a fault occurs, it should be able to send out a fire alarm signal and a clear distinction between the sound of failure in 100s, Optical signal, the optical signal fault should be kept to troubleshooting. Acoustic signal detector should be able to eliminate the manual, when a new fault signal sound signal generator Students should start again. The detector should be able to display the following types of failure.

a) mains failure or undervoltage;

b) to alternate between the power supply and standby power charger charging cable break, short-circuit;

c) between the standby power supply and its load cable break, short circuit or powered by a separate standby power supply when the voltage is insufficient to protect the detector normal work. 4.3.2.3.3 Power Capability

a) AC power supply When AC-powered detector at 110% and 85% of rated voltage condition, should be able to work, and having a main and backup power Source conversion function. When the main power fails, you should be able to automatically switch to standby power; when the main power is restored, should automatically switch to The main power supply; there should be main and backup power working status indication, the main power supply should over-current protection measures. Main and backup power conversion should not be Detector sends a fire alarm signal.

b) standby power Backup power to the discharge end voltage conditions, charging 24h, its capacity should be able to ensure normal monitoring state detector getting off work After work 8h, working in an alarm state conditions 30min. 4.3.2.3.4 Self-Test Detectors should manually check all the panel LEDs display function. During the implementation of the self-test, subject to its control output contacts Should not action. When the detector self-test for more than 1min or not automatically stop the self-test function, the detector should not affect the self-test function Non-self-test site and the fire alarm detector itself. 4.3.2.3.5 Reset Detectors should only be reset by means of special tools, password or the like. 4.3.2.3.6 turning on and off Opening and closing of the power detector should only be by means of special tools, password or the like.

4.3.3 Response threshold

4.3.3.1 Response threshold detector should meet the requirements specified in Table 7. Table

7 Response threshold requirement When the response threshold value of the detector in the table 1 and two adjustable intervals two or more, there should be the response threshold value indicates where the range and meet with Upon request. Response threshold detector measurement method

4.3.3.2 shall be carried out as follows: Normal monitoring state 4.3.3.2.1 Test If the probe in the test method requires working in a normal state of surveillance, control and indicating equipment should be provided by the manufacturer of the sample and Connection; no special requirements in the relevant provisions, should ensure that the detector's operating voltage is rated voltage, and during the test to keep workers For voltage stability.

Note. the detector test report shall specify the period of the test model of the detector is connected with the control and indicating equipment, manufacturers and so on. 4.3.3.2.2 Detector Installation Line sampling detectors shall be specified by the manufacturer of the normal installation maximum line length of installation, if the instructions given more security Installed by the way, it should be used to test the detector work most unfavorable installation in the most unfavorable sampling openings measure the response threshold. Point type-sampling probe Detector shall be specified by the manufacturer for normal mounting method. If the specification is given a...

5 Normal monitoring state

4.2 point infrared flame detector

4.2.1 Response consistency threshold distribution Under normal environmental conditions, measuring the response of each detector threshold than the maximum response threshold value to the minimum response threshold value should be less than 2.0.

4.2.2 Repeatability Under normal ambient conditions, for six consecutive measurements on any one position only the same detector response threshold value, the maximum value to the minimum response threshold Response threshold ratio should not exceed 1.3.

4.2.3 orientation The detector axis and the optical axis angle are 0 °, 15 °, 30 °, 45 °, each measuring response time threshold, cone angle detector should not Less than 45 °, than the maximum response threshold value to the minimum response threshold value should not be greater than 2.0.

4.2.4 energized The detector should be able to run continuously in the normal monitoring state 7d. During the test, the sample should not send out a fire alarm signal or fault signal. After the test, the response threshold of the detector response threshold value in the consistency test, compared to more than the maximum response threshold value to the minimum response threshold It should be less than 1.3.

4.2.5 Power parameter fluctuations Detector supply voltage of -15% and + 10% of rated voltage measured detector response threshold value, and conformance testing of Response compared to a threshold, than the maximum response threshold value to the minimum response threshold value should not be greater than 1.6.

4.2.6 ambient light interference Ambient light detector during the following action should send out a fire alarm signal or fault signal. After ambient light interference, in white Incandescent lamps and fluorescent detectors simultaneously measure the response threshold value under the lighting conditions, the response threshold value in response to the detector in the consistency Test Compared to a threshold, ratio of the maximum response threshold value to the minimum response threshold value should not exceed 1.6. After the test, the sample should be the response threshold ratio Smax.Smin Not more than 1.3.

a) with two 25W incandescent lamp (color temperature of 2850K ± 100K), put out the light 1s 1s, a total of 20 times.

b) with a diameter of 308mm, 30W circular fluorescent lamp, put out the light 1s 1s, a total of 20 times.

c) using the above incandescent and fluorescent lamps, light 2h.

4.2.7 Fire sensitivity In Table 6, the specified test conditions of fire, detectors should send out a fire alarm signal within 30s. Send out a fire alarm signal when the sample With a distance of 25m center fire test when the sensitivity level I, grade II sensitivity at 17m, grade III sensitivity at 12m. Table

6 Fire sensitivity test fire conditions require Name test fire test fire conditions N-heptane fire Fuel heptane (analytical grade), plus 3% (by volume) toluene Quality 650g Arrangement will be placed in the fuel made of 2mm thick steel plate, a bottom size of 33cm × 33cm, height 5cm container Flame or spark ignition Ethanol fire Industrial fuel ethanol (90% ethanol content, containing a small amount of methanol) 2000g Quality Arrangement will be placed in the fuel made of 2mm thick steel plate, a bottom size of 33cm × 33cm, height 5cm container Flame or spark ignition

4.3 aspirating smoke detector

4.3.1 pipeline sampling type aspirated smoke detector main component performance

6 Each discharge point 10 times Discharge Polarity Positive, Negative Interval/s >=

1 Normal monitoring state Table 5 (Continued) Name of Test Test Parameters Test Conditions Operating status Electrical Fast Transient Immunity Test Peak voltage/kV 1 × (1 ± 0.1) Repetition frequency/kHz 5 × (1 ± 0.2) Polarity Positive, Negative Each time 1min Normal monitoring state Surge (impact) Immunity Test Surge voltage/kV line - to 1 × (1 ± 0.1) Polarity Positive, Negative Test times

20 No power

4.1.9 Electromagnetic compatibility tests The detector should be able to withstand the electromagnetic compatibility tests in Table 5 prescribed during the test and after the test shall meet the following requirements.

a) During the test, the detector should send out a fire alarm signal or fault signal;

b) After the test, the detector should be able to work properly; the response threshold point infrared flame detector and its response in conformance Test Compared to a threshold, ratio of the maximum response threshold value to the minimum response threshold value should not be greater than 1.3; aspirating smoke detectors and fire point type Carbon monoxide fire detector response threshold value of its response threshold value in the consistency test, compared with the maximum response threshold value Smaller than the response threshold value should not be greater than 1.6; the response threshold image type fire detector should meet the requirements of 4.4.1. Table

5 Electromagnetic compatibility test conditions require Name of Test Test Parameters Test Conditions Operating status Radio frequency electromagnetic radiation Immunity Test Field/(V/m)

10 Frequency range/MHz 80 ~ 1000 Modulation amplitude 80% (1Hz, sine) Sweep rate/(10oct/s) <=1.5 × 10-

3 Normal monitoring state RF conducted disturbances, induced field Immunity Test Voltage/dBµV 140 Frequency range/MHz 0.15 ~ 100 Modulation amplitude 80% (1Hz, sine) Sweep rate/(10oct/s) <=1.5 × 10-

3 Normal monitoring state Electrostatic discharge Immunity Test Discharge voltage/kV Air discharge (insulator shell sample)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 39 pages — is available in the English PDF.

Referenced standards

Editions of GB 15631

EditionTitleRevisionStatus
GB 12791-2025Special type fire detectorsnext editionReplaces this edition
GB 15631-2008Special type fire detectorscurrent editionCurrent
GB 15631-1995Special type fire detectorsprevious editionSuperseded

This page sells the current edition, GB 15631-2008. Earlier editions are listed for reference only.

How to Buy GB 15631-2008

  1. 1Add to cart. Click the "Buy GB 15631-2008" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
39 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 15631-2008

$390.00

$330.00for partners