GB 14249.1-1993Safety requirements for electronic weighing instruments (English PDF)
电子衡器安全要求
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB 14249.1-1993 in 30 minutes.
Issued by
AQSIQ
Level / Type
National · Mandatory
Issue date
March 16, 1993
Implementation date
November 1, 1993
Scope
GB 14249.1-1993 is the English-translated version of 电子衡器安全要求.
GB 14249.1-1993 specifies the safety technical requirements and test methods for electronic weighing instruments that rely on earthing for protection against electric shock; it may also be applied to Class II instruments and applies to explosion-proof instruments used in severe environments.
It sets the rated operating conditions for load cells, indicators and other parts, and requirements for temperature rise, explosion protection, protection against electric shock, protective earthing (connection resistance below 0.5 Omega, earthing resistance below 4 Omega), wiring and electrical connections, mechanical construction, insulation (indicator insulation resistance of at least 5 MOmega, 1 500 V withstand for 1 min, leakage current not above 3.5 mA), components, fuses, switches and external flexible cords.
The test methods refer largely to GB 8898, GB 7551, GB 6587 and GB 3836, and include a 10 A earth continuity test, a 1 500 V wire insulation test and a 48 h damp heat test at 40 °C, followed by marking requirements for safety and power supply.
It is the first edition, issued on 16 March 1993 and in force since 1 November 1993, and is replaced by GB 14249-2026. Classification: CCS N 13. The document runs to 6 pages, delivered complete in English translation.
Found what you need?
Document preview — GB 14249.1-1993
National Standard of the People's Republic of China
- Classification
- N 13
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Foreword1
- 1 Subject content and scope of application1
- 2 Normative references1
- 3 Terms, symbols and codes1
- 4 Technical requirements1
- 4.1 Rated operating conditions and fault conditions1
- 4.1.1 Rated operating conditions1
- 4.1.2 Fault conditions2
- 4.2 High temperature and other hazards2
- 4.2.1 Temperature rise under rated operating conditions and fault conditions2
- 4.2.1.1 Permitted temperature rise under rated operating conditions2
- 4.2.1.2 Temperature rise under fault conditions2
- 4.3 Explosion protection2
- 4.4 Protection against electric shock by contact2
- 4.4.1 Accessible parts2
- 4.4.2 Preset controls2
- 4.4.3 Mains plugs2
- 4.5 Construction requirements2
- 4.5.1 Protection against electric shock2
- 4.5.1.1 Protective earthing terminal2
- 4.5.1.2 Protective earthing2
- 4.5.1.3 Wiring2
- 4.5.1.4 Electrical connections3
- 4.5.2 Mechanical construction3
- 4.6 Insulation requirements3
- 4.6.1 Damp heat treatment and insulation requirements3
- 4.6.1.1 Damp heat effects and insulation requirements for load cells3
- 4.6.1.2 Damp heat effects and insulation requirements for indicators3
- 4.7 Components3
- 4.8 Fuses3
- 4.9 Power switches3
- 4.10 Terminals for external flexible cords3
- 4.11 External flexible cords3
- 4.12 Electrical connections and mechanical fixings3
- 5 Test methods3
- 5.3 Tests for protection against electric shock by contact3
- 5.4 Tests for protection against electric shock3
- 5.5 Damp heat treatment and insulation requirements4
- 5.6 Mechanical strength tests4
- 6 Marking4
- 6.1 Safety marking4
- 6.2 Power supply marking5
Foreword
National Standard of the People's Republic of China GB 14249.1-93, Safety requirements for electronic weighing instruments.
Approved by the State Bureau of Technical Supervision on 1993-03-16; implemented on 1993-11-01.
Additional information: this standard was proposed by the Ministry of Light Industry of the People's Republic of China.
This standard is under the jurisdiction of the National Technical Committee on Weighing Instruments of Standardization.
This standard was drafted by Shanghai Metallurgical Instrument and Metrology Factory.
Principal drafters of this standard: Wei Jinbao, Xiao Yong.
1 Subject content and scope of application
This standard specifies the safety technical requirements and test methods for electronic weighing instruments.
This standard applies to electronic weighing instruments whose construction relies on earthing to provide protection against electric shock (hereinafter referred to as electronic weighing instruments), and may also be applied to Class II electronic weighing instruments. This standard also applies to electronic weighing instruments used under severe environmental conditions (explosion-proof).
2 Normative references
GB 985 Basic forms and dimensions of weld grooves for gas welding, manual metal arc welding and gas-shielded arc welding
GB 986 Basic forms and dimensions of weld grooves for submerged arc welding
GB 2651 Method of tensile test for welded joints
GB 3100 to 3102 Quantities and units
GB 3836 Explosion-proof electrical apparatus for explosive atmospheres
GB 4793 Safety requirements for electronic measuring instruments
GB 5465.2 Graphical symbols for use on electrical equipment
GB 6587.4 Vibration test for electronic measuring instruments
GB 6587.5 Shock test for electronic measuring instruments
GB 6587.7 Basic safety tests for electronic measuring instruments
GB 7551 Resistance strain gauge load cells
GB 7724 Technical requirements for weighing indicators
GB 8898 Safety requirements for mains-operated electronic and related apparatus for household and similar general use
GBJ 65 Code for design of earthing of industrial and civil electric power installations
GB/T 14250 Terms of weighing instruments
3 Terms, symbols and codes
Terms, symbols and codes shall comply with GB 14250.
4 Technical requirements
4.1 Rated operating conditions and fault conditions
4.1.1 Rated operating conditions
4.1.1.1
Load cells (hereinafter referred to as sensors) shall be able to operate safely under the following conditions:
Temperature: -10 °C to +55 °C; relative humidity: 5% to 90%; atmospheric pressure: 86 kPa to 106 kPa.
4.1.1.2
Weighing indicators (hereinafter referred to as indicators) shall be able to operate safely under the following conditions:
Temperature: 10 °C to 20 °C for class I and class II weighing instruments; 0 °C to 40 °C for class III and class IIII weighing instruments and automatic weighing instruments.
Relative humidity: less than 75% for class I and class II weighing instruments; less than 90% for class III and class IIII weighing instruments and automatic weighing instruments.
Rated voltage: 220 V, variation range -15% to +10%;
Rated frequency: 50 Hz, variation range -2% to +2%.
4.1.1.3
The other parts of the electronic weighing instrument shall be able to operate safely in the range -10 °C to +40 °C.
Stricter ranges than the above conditions may be specified by agreement between the manufacturer and the user.
4.1.2 Fault conditions
a. environmental conditions exceeding the rated operating conditions;
b. parts actually used exceeding the requirements of the technical specification;
c. failure of parts or components.
4.2 High temperature and other hazards
4.2.1 Temperature rise under rated operating conditions and fault conditions
4.2.1.1 Permitted temperature rise under rated operating conditions
No accessible part of the electronic weighing instrument shall reach an unsafe temperature liable to injure persons, and no part or component shall reach a temperature liable to damage electrical insulation or reduce mechanical strength. The maximum safe temperature rises under rated operating conditions are the values specified in column 1 of Table II of GB 8898.
4.2.1.2 Temperature rise under fault conditions
The permitted temperature rises of electronic weighing instruments operating under fault conditions are the values specified in column 2 of Table II of GB 8898.
4.3 Explosion protection
Explosion-proof electronic weighing instruments operating in environments where flammable gases, vapours, dusts or other flammable or explosive substances are present shall be manufactured in accordance with GB 3836 and with the basic requirements of the Electrical Safety Regulations for Explosion Hazardous Locations of the People's Republic of China (Trial).
4.4 Protection against electric shock by contact
4.4.1 Accessible parts
Accessible parts shall not be live; even inaccessible earth terminals shall not be live.
4.4.2 Preset controls
Where the enclosure has holes through which controls can be adjusted with a tool, there shall be no danger of electric shock when the controls are adjusted.
4.4.3 Mains plugs
Electronic weighing instruments connected to the mains supply by a plug shall not give rise to a danger of electric shock when the plug is inserted or withdrawn.
4.5 Construction requirements
4.5.1 Protection against electric shock
4.5.1.1 Protective earthing terminal
Electronic weighing instruments shall have a protective earthing terminal or earthing point, and all accessible conductive parts shall be reliably connected to the protective earth.
The connection resistance between accessible parts and the protective earthing terminal shall be less than 0.5 Omega.
a. Parts of electronic weighing instruments located outdoors shall have a separate protective earthing terminal. The material of the earthing terminal shall be compatible in electrolytic behaviour with the earthing conductor, and the earthing terminal shall be such that it cannot be loosened by hand;
b. The requirements of a. also apply to electronic weighing instruments with non-detachable flexible cords or cables. In addition, every non-detachable flexible cord or cable connected to the mains shall have a green/yellow core connected to the protective earthing terminal of the indicator and, where there is a plug, to the protective earthing contact of the plug.
4.5.1.2 Protective earthing
The earthing arrangement shall be connected by specially laid conductors of suitably low impedance, so as to ensure that accessible parts are electrically safe under rated operating conditions and under fault conditions. The earthing resistance shall be less than 4 Omega.
4.5.1.3 Wiring
The insulation between live conductors in wires (or cables) and accessible components, or the insulation of wires (or cables) connecting live components to accessible metal parts, shall be able to withstand the dielectric strength test of 5.4.3, and its thickness shall provide equivalent mechanical strength.
4.5.1.4 Electrical connections
a. Short-circuiting of the insulation between live components and accessible components as a result of the loosening of connecting screws, etc. shall be prevented;
b. It shall be ensured that, if one end of any wire becomes loose, the natural movement of the loose end does not reduce the creepage distances and clearances in air below the values shown by curve A of Table II of GB 8898 (0.6 mm for 34 V, 3.0 mm for 354 V).
4.5.2 Mechanical construction
a. Sensors and indicators shall be able to withstand vibration and shock tests;
b. Sensors and load receptors shall be designed so as to minimise the possibility of mechanical injury to persons, for example injury caused by sharp edges, burrs or protruding corners;
c. The groove dimensions and deviations of welded parts shall comply with the relevant requirements of GB 985.
4.6 Insulation requirements
4.6.1 Damp heat treatment and insulation requirements
4.6.1.1 Damp heat effects and insulation requirements for load cells
The damp heat effects and the insulation resistance of sensors shall comply respectively with the relevant provisions of GB 7551.
4.6.1.2 Damp heat effects and insulation requirements for indicators
a. The damp heat effects on the indicator shall comply with the relevant provisions of GB 7724;
b. The insulation resistance of the indicator shall be not less than 5 MOmega;
c. In the dielectric strength test of the indicator, there shall be no breakdown at an a.c. voltage of 1 500 V applied for 1 min;
d. The power-frequency a.c. leakage current shall not exceed 3.5 mA.
4.7 Components
Under rated operating conditions the load on components shall not be permitted to exceed their rated values, and under fault conditions it shall as far as possible not exceed them.
4.8 Fuses
Suitable fuses shall be fitted to ensure safe and reliable operation.
4.9 Power switches
Power switches shall maintain good making and breaking capability.
4.10 Terminals for external flexible cords
Terminals for external flexible cords shall comply with the relevant provisions of Chapter 15 of GB 8898.
4.11 External flexible cords
External flexible cords shall comply with the relevant provisions of Chapter 16 of GB 8898.
4.12 Electrical connections and mechanical fixings
The electrical connections and mechanical fixings of the parts of electronic weighing instruments shall comply with the relevant provisions of Chapter 17 of GB 8898.
5 Test methods
5.1
The temperature rise test under the rated temperature limit conditions shall be carried out in accordance with 7.1 of GB 8898.
5.2
Explosion-proof electronic weighing instruments for explosion hazardous locations may be produced and used only after they have been inspected and found acceptable, in accordance with the relevant provisions of GB 3836 and of the Electrical Safety Regulations for Explosion Hazardous Locations of the People's Republic of China (Trial), by a national explosion protection safety supervision and inspection station (explosion protection station for short) established with the approval of the Ministry of Labour.
5.3 Tests for protection against electric shock by contact
5.3.1
The test of preset controls shall be carried out in accordance with 9.1.5 of GB 8898.
5.3.2
The test of mains plugs shall be carried out in accordance with 9.1.7 of GB 8898.
5.4 Tests for protection against electric shock
5.4.1
The connection resistance between accessible parts and the protective earthing terminal shall be less than 0.5 Omega. The connecting leads may be preselected by calculation; then, using an a.c. source with a no-load voltage not exceeding 6 V, a current of 10 A is passed for 1 min in turn through the connection between each protective earthing terminal and the accessible metal parts, the voltage drop between them is measured, and the resistance is finally calculated from the current and the voltage drop:
R = U / I < 0.5 Omega
where:
R - connection resistance, Omega;
U - measured voltage drop, V;
I - applied current, 10 A.
Note 1: the resistance of the flexible cord is not included in the measured resistance.
Note 2: the contact resistance between the tip of the measuring probe and the accessible metal part shall not affect the test result.
Note 3: if the rated supply voltage is relatively low, the resistance value shall be reduced.
5.4.2
The earthing resistance of electronic weighing instruments shall be determined in accordance with the relevant provisions of GBJ 65.
5.4.3
Test of the insulation of wires. A metal foil at least 10 cm long is first wrapped tightly around the insulation of the wire, and a test voltage of 1 500 V a.c. is then applied between the conductor of the wire and the metal foil. During the test the voltage is raised gradually to the specified value so as to avoid any appreciable transient, held at the specified voltage for 1 min, and then reduced smoothly to zero. No flashover or breakdown shall occur during the test, but corona effects and similar phenomena are permitted.
5.4.4
The construction tests of electronic weighing instruments cover electrical connections and mechanical performance.
a. In the construction of the electronic weighing instrument, if the measures taken to prevent short-circuiting of the insulation between live components and accessible components caused by accidentally loosened screws, etc. withstand the tests of 5.4.4c and 5.4.4d, the requirements are considered to be met;
b. The construction of the electronic weighing instrument shall ensure that, if one end of any wire becomes loose, the natural movement of the loose end does not reduce the creepage distances and clearances in air below the values shown by curve A of Table II of GB 8898; compliance is checked by inspection and measurement;
c. If the sensor passes the vibration and shock tests carried out in accordance with the relevant provisions of GB 7551, the requirements are considered to be met;
d. If the indicator passes the vibration and shock tests carried out in accordance with GB 6587.4 and GB 6587.5, the requirements are considered to be met.
5.5 Damp heat treatment and insulation requirements
5.5.1
If the damp heat effect test and the insulation resistance test of the sensor, carried out in accordance with the relevant provisions of GB 7551, are passed, the requirements are considered to be met.
5.5.2
In the damp heat test of the indicator, the indicator is placed in a damp heat chamber at a temperature of 40 °C ± 2 °C and a relative humidity of 90% to 95% and kept there for 48 h; immediately after the test, the tests of 3.1, 3.2 and 3.3 of GB 6587.7 are carried out.
5.6 Mechanical strength tests
5.6.1
The external appearance of all parts of the electronic weighing instrument shall be checked visually for compliance.
5.6.2
Welded parts are in general checked visually. Welds that require mechanical performance tests shall be indicated in the drawings or technical requirements. Mechanical performance tests of welds shall be carried out in accordance with GB 2651.
5.7
Components that have been shown to comply with the safety requirements by tests appropriate to the rated operating conditions need not be tested.
Components not falling within the above case shall be tested inside or outside the electronic weighing instrument (under conditions equivalent to the rated operating conditions of the component within the instrument).
5.8
The capacity of fuses shall be accepted in accordance with the factory product standard.
5.9
Switches shall be checked for compliance visually and by measurement.
5.10
The test of terminals for external flexible cords shall be carried out in accordance with 15.3 of GB 8898.
5.11
The test of external flexible cords shall be carried out in accordance with the relevant provisions of Chapter 16 of GB 8898.
5.12
The electrical connections and mechanical fixings of the parts of electronic weighing instruments shall be checked in accordance with Chapter 17 of GB 8898.
6 Marking
6.1 Safety marking
6.1.1
The number of the explosion protection certificate of explosion-proof products shall be marked on the product nameplate.
6.1.2
The symbols and letters of quantities and units shall comply with GB 3100 to 3102.
6.1.3
Graphical symbols shall comply with GB 5465.
6.2 Power supply marking
a. an a.c. supply shall be indicated by the symbol "~";
b. a d.c. supply shall be indicated by the symbol "-";
c. where safety depends on the correct mains frequency, the rated mains frequency shall be marked;
d. switches shall be clearly marked with their on and off positions;
e. fuses shall be clearly marked;
f. protective earthing shall bear an earthing symbol.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 3100SI units and recommendations for the use of their multiples and of certain other units
- GB 3101Quantities and units. General principles
- GB 4793Safety technical specification for electrical equipment for measurement,control and laboratory use
- GB/T 14250Terminology of weighing instruments
GB 985 · GB 986 · GB 2651 · GB 3102 · GB 3836 · GB 5465.2 · GB 6587.4 · GB 6587.5 · GB 6587.7 · GB 7551 · GB 7724 · GB 8898 · GBJ 65
Cited by
- GB/T 46398-2025Loss in weight feeder
- GB/T 15561-2024Digital indication rail-weighbridges
- NB/T 10718-2021Belt scale for the mine
- GB/T 11883-2017General technical specification for electronic crane and hanging scale
- GB/T 34850-2017Weighing instruments for mining car in motion
- GB/T 35593-2017Chute weighing instruments
Editions of GB 14249.1
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB 14249-2026 | Safety requirements for electronic weighing instruments | next edition | Replaces this edition |
| GB 14249.1-1993 | Safety requirements for electronic weighing instruments | current edition | Current |
This page sells the current edition, GB 14249.1-1993. Earlier editions are listed for reference only.
How to Download GB 14249.1-1993
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards