GA 793.1-2008Conformity assessment of city area monitoring and alarming network system--Part 1: Testing and verifying specifications for the functions and performance of system (English PDF)
城市监控报警联网系统 合格评定 第1部分:系统功能性能检验规范
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for GA 793.1-2008 in 30 minutes.
Issued by
Ministry of Public Security
Level / Type
National · Mandatory
Issue date
August 4, 2008
Implementation date
August 4, 2008
Scope
GA 793.1-2008 is the English-translated version of 城市监控报警联网系统 合格评定 第1部分:系统功能性能检验规范.
GA 793.1-2008 — The provisions of section GA 793 urban network alarm monitoring system (hereinafter referred to as networked systems) conformity assessment system functionality, performance the basic specification of the test, including general provisions, test procedures, test items, test requirements and test methods.
This section applies to urban network alarm monitoring system construction in new construction, renovation, expansion of the system of inspection.
Found what you need?
Document preview — GA 793.1-2008
National Standard of the People's Republic of China
- ICS
- 13.310
- Classification
- A 91
Issued by: Ministry of Public Security
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 1 General Provisions
- 5 2 testing procedures
- 2 5.1 Test Registration
- 5.2 Test preparation
- 5.3 Test Example
- 5.4 Test Results and Treatment
- 6 Networking system functionality, performance test
- 6.1 Networking System Networking before examination
- 6.2 Networking System function test
- 6.3 Networking system performance test
- 7 7 networking systems security test
- 8 EMC networked system equipment, environmental adaptability test
- 9 9 Networking System Reliability Testing
- 10 Network system construction quality, inspection equipment installation
Foreword
Please note that the basic content of this section may involve patents, this part of the release mechanism should not bear the responsibility to identify these patents.
Provisions of this Part 6,7,10 chapter with "" for mandatory provisions, other provisions are recommendatory.
GA 793 "urban network alarm monitoring system conformity assessment" is divided into three parts.
--- Part 1. System function test performance specifications;
--- Part 2. Test Specification management software platform;
--- Part 3. System acceptance.
This section is part of the 1 GA 793.
This part is proposed by the Ministry of Public Security Technology Bureau.
This part of the National Security Alarm System Standardization Technical Committee (SAC/TC100) centralized.
This section drafted by. National Security Alarm System Product Quality Supervision and Inspection Center (Beijing), Ministry of Public Security First Research Institute, Beijing Univision Aegis security technology company, the Guangdong Provincial Public Security Department of Science and Technology.
1 Scope
The provisions of section GA 793 urban network alarm monitoring system (hereinafter referred to as networked systems) conformity assessment system functionality, performance the basic specification of the test, including general provisions, test procedures, test items, test requirements and test methods.
This section applies to urban network alarm monitoring system construction in new construction, renovation, expansion of the system of inspection.
2 Normative references
The following documents contain provisions which, through reference in this GA 793 constitute provisions of this part. For dated references, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section are all aspects of the research to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
Alarm equipment safety requirements and test methods GB 16796-1997 security GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2:2001, IDT) GB/T 17626.4-1998 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test (idt IEC 61000-4-4:1995) GB 20815-2006 video monitoring digital video equipment GB 50198-1994 civil closed circuit monitoring TV system engineering GB 50348-2004 security engineering and technical norms GA/T 669.1-2008 urban network alarm monitoring system technical requirements - Part 1. General technical requirements GA/T 669.2-2008 urban network alarm monitoring system technical requirements - Part 2. Safety requirements GA/T 669.6-2008 urban network alarm monitoring system technical requirements - Part 6. Depending on the audio display, storage and playback technology Claim GA/T 669.8-2008 urban network alarm monitoring system technical requirements - Part 8. transmission platform technology requirements GA/T 669.9-2008 urban network alarm monitoring system of technical standards Part 9. bayonet information recognition, matching, monitoring system EC technical requirements GA/T 669.10-2008 city Part 10 technical standards for network alarm monitoring system. wireless audio and video surveillance system technology Claim GA/T 670-2006 security systems, lightning surge protection Technical Requirements GA 793.2-2008 urban network alarm monitoring system of conformity assessment - Part 2. Test Specification Management Platform software
3 Terms and Definitions
GB 50348-2004, terms and definitions GA/T 669.1-2008 established in this section apply.
4 General Provisions
4.1 Networking System test shall be authorized by national or industry (approved) the inspection organizations.
4.2 networking system before testing, the system should try to run at least a month.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 16796-1997Security alarm equipment - Safety requirements and test methods
- GB/T 17626.2-2006Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.4-1998Electromagnetic compatibility -- Testing and measurement techniques -- Electrical fast transient/burst immunity test
- GB 20815-2006Digital video record equipment of video surveillance system in security & protection systems
- GB 50198-1994Technical code for project of civil closed circuit monitoring television system
- GB 50348-2004Technical standard for security engineering
IEC 61000
How to Download GA 793.1-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 20815-2006 — Digital video record equipment of video surveillance system in security & protection systems
GA 793.2-2008 — Conformity assessment of city area monitoring and alarming network system--Part 2: Testing specification of management platform softweare
GA 40-2025 — The filing documents of road traffic
Secure payment via Stripe
Payments accepted
GA 793.1-2008
$394.00