DL/T 1538-2016Application guide for vacuum on-load tap-changers for power transformers (English PDF)

电力变压器用真空有载分接开关使用导则

Preview PDF

This is a limited preview

Buy now to download the full PDF (32 pages)

Need quotation for your management?

Get a formal quotation for DL/T 1538-2016 in 30 minutes.

Issued by

NEA

Level / Type

Industry · Recommended

Issue date

January 7, 2016

Implementation date

June 1, 2016

Scope

DL/T 1538-2016 is the English-translated version of 电力变压器用真空有载分接开关使用导则.

DL/T 1538-2016 is the Chinese power industry guide for the application of vacuum on-load tap-changers in power transformers - the switches that change the transformer ratio under load to hold the network voltage, with the arcing enclosed in vacuum interrupters instead of in the transformer oil. Vacuum switching keeps the tap-changer oil clean and extends the maintenance interval, but the device has its own failure modes, so utilities and transformer builders need common rules for selecting, protecting, testing and maintaining it. The guide specifies the performance of resistor-type vacuum on-load tap-changers, their protection configuration, the test items and test methods, the scope of use, and the requirements for operation and maintenance. It applies to resistor-type vacuum on-load tap-changers fitted to power transformers of 220 kV and below; tap-changers of other transformers may follow it or the manufacturer's instructions, and reactor-type vacuum tap-changers are excluded. Issued by the National Energy Administration on 7 January 2016, it has applied since 1 June 2016.

Found what you need?

Document preview — DL/T 1538-2016

National Standard of the People's Republic of China

ICS
29.180
Classification
K 41

Issued by: National Energy Administration of the People's Republic of China

Contents

  • ForewordII
  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and definitions1
  • 4 Classification and mounting2
  • 5 Technical performance3
  • 6 Motor-drive mechanism4
  • 7 Protection requirements4
  • 8 Selection principles6
  • 9 Tests6
  • 10 Installation and acceptance8
  • 11 Operation9
  • 12 Maintenance9
  • 13 Inspection and handling of abnormal conditions11
  • Annex A (informative) Typical schematic diagrams of the diverter switch of vacuum on-load tap-changers13
  • Annex B (informative) Test items and requirements of vacuum on-load tap-changers that differ from JB/T 831414
  • Annex C (informative) Filling pressure of SF6 vacuum on-load tap-changers and operating characteristics of the gas sudden-pressure relay22
  • Annex D (informative) Typical service conditions and insulation levels of on-load tap-changers on power transformers of 220 kV and below23
  • Annex E (informative) Test method for the combined waveform of vacuum on-load tap-changers26

Foreword

This document was issued on 7 January 2016 by the National Energy Administration of the People's Republic of China, and has applied since 1 June 2016. Filing number 53959-2016.

It is a DL/T standard: a recommended industry standard of China's electric power sector.

This standard is drafted in accordance with the rules given in GB/T 1.1-2009, Directives for standardization - Part 1: Structure and drafting of standards.

This standard was proposed by the China Electricity Council.

This standard is under the jurisdiction of the Technical Committee for Standardization of Power Transformers of the Electric Power Industry (DL/TC 02).

This standard is issued for the first time.

Comments and suggestions arising in the implementation of this standard may be sent to the Standardization Management Centre of the China Electricity Council (No. 1, Baiguang Road Ertiao, Beijing, 100761).

1 Scope

This standard specifies the performance, protection configuration, test items, test methods, range of application and operation and maintenance requirements of resistor-type vacuum on-load tap-changers.

This standard applies to resistor-type vacuum on-load tap-changers fitted to power transformers of 220 kV and below. Vacuum on-load tap-changers for transformers other than power transformers may follow this standard or the manufacturer's instructions.

This standard does not apply to reactor-type vacuum on-load tap-changers.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies.

GB/T 6451-2015, Specification and technical requirements for oil-immersed power transformers

GB 10230.1-2007, Tap-changers - Part 1: Performance requirements and test methods

GB/T 10230.2-2007, Tap-changers - Part 2: Application guide

GB 11032-2010, Metal-oxide surge arresters without gaps for a.c. systems

GB/T 16927.1, High-voltage test techniques - Part 1: General definitions and test requirements

GB/T 22065, Pressure-type SF6 gas density controllers

DL/T 537, Selection guide for high-voltage/low-voltage prefabricated substations

DL/T 574-2010, Guide for operation and maintenance of transformer tap-changers

DL/T 596-2005, Preventive test code for electric power equipment

JB/T 7065, Pressure relief valves for transformers

JB/T 8314-2008, Tap-changers - Test guide

JB/T 9647, Gas relays for transformers

JB/T 10372, Hydraulic pressure relays

JB/T 10892, Electronic SF6 density transmitters

3 Terms and definitions

For the purposes of this document, the terms and definitions given in GB 10230.1 and GB/T 10230.2 and the following apply.

3.1 vacuum on-load tap-changer: on-load tap-changer that uses vacuum interrupters to break and make the load current and the circulating current. The insulating medium of the tap-changer body is oil (mineral oil or other fire-resistant or environmentally friendly substitute oils, referred to as insulating oil) or gas (air or SF6).

3.2 transfer contact (connected with vacuum interrupter): electrical contact of a vacuum on-load tap-changer that is connected in series with a vacuum interrupter and, together with it, performs the tap-change operation.

3.3 main switching vacuum interrupter: vacuum interrupter that makes and breaks the load current and/or the circulating current and has no transition resistor between it and the transformer winding.

3.4 transition vacuum interrupter: vacuum interrupter connected in series with a transition resistor, able to make and break the load current and/or the circulating current.

3.5 combined on-load tap-changer: on-load tap-changer in which the tap change is performed by a diverter switch combined with a tap selector.

3.6 compound on-load tap-changer: on-load tap-changer in which the tap change is performed by a selector switch.

Remaining clauses in the full document

  • 4 Classification and mounting
  • 4.1 Classification of vacuum on-load tap-changers
  • 4.2 Mounting of vacuum on-load tap-changers
  • 5 Technical performance
  • 5.1 General
  • 5.4 Drying requirements
  • 5.7 Main technical parameters to be provided in the factory documentation
  • 5.8 Other technical performance
  • 6 Motor-drive mechanism
  • 7 Protection requirements
  • 7.1 Protection of the separate oil compartment (oil-immersed vacuum on-load tap-changers)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 32 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download DL/T 1538-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
32 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

DL/T 1538-2016

$575.00