Scope
DL/T 1498.1-2016 is the English-translated version of 变电设备在线监测装置技术规范 第1部分:通则.
DL/T 1498.1-2016 is the Chinese standard "Technical specification for on-line monitoring device of transformation equipment - Part 1: General technical specification".
Its scope clause reads: This section specifies the technical requirements, test, inspection rules, marking, packaging, transportation and storage of the on-line monitoring devices of transformation equipment.
This part applies to the on-line monitoring devices of transformers, reactors, circuit breakers, gas insulated metal enclosed switchgear (GIS), capacitive equipment, metal oxide arrester and other transformation equipment; AND other online monitoring devices may make reference to this part.
Found what you need?
Document preview — DL/T 1498.1-2016
National Standard of the People's Republic of China
- ICS
- 29.040.10
- Classification
- E 38
Issued by: National Energy Administration of the PRC
Contents
- Foreword4
- 1 Scope6
- 2 Normative references6
- 3 Terms and definitions7
- 4 Working conditions8
- 4.1 Normal working conditions8
- 4.2 Special working conditions9
- 5 Technical requirements9
- 5.1 Safety performance9
- 5.2 Reliability10
- 5.3 Structure and appearance requirements10
- 5.4 Basic functional requirements10
- 5.5 Measurement error12
- 5.6 Insulation performance12
- 5.7 Electromagnetic compatibility13
- 5.8 Environmental adaptability14
- 5.9 Mechanical properties15
- 5.10 Enclosure protection performance15
- 6 Test15
- 6.1 Test conditions15
- 6.2 Structure and appearance inspection16
- 6.3 Basic function test16
- 6.4 Measurement error test16
- 6.5 Insulation performance test16
- 6.6 Electromagnetic compatibility test17
- 6.7 Environmental adaptability test18
- 6.8 Mechanical performance test19
- 6.9 Enclosure protection performance test20
- 7 Inspection rules20
- 7.1 Inspection category20
- 7.2 Type test21
- 7.3 Exit-factory test21
- 7.4 Handover test22
- 7.5 Field test22
- 8 Marking, packaging, transportation and storage22
- 8.1 Marking22
- 8.2 Packaging23
- 8.3 Transportation23
- 8.4 Storage23
1 Scope
This section specifies the technical requirements, test, inspection rules, marking, packaging, transportation and storage of the on-line monitoring devices of transformation equipment.
This part applies to the on-line monitoring devices of transformers, reactors, circuit breakers, gas insulated metal enclosed switchgear (GIS), capacitive equipment, metal oxide arrester and other transformation equipment; AND other online monitoring devices may make reference to this part.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this Standard.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 2423.1 Environmental testing for electric and electronic products -
Part 2. Test methods - Test A. Cold
GB/T 2423.2 Environmental testing for electric and electronic products -
Part 2. Test methods - Test B. Dry heat
GB/T 2423.3 Environmental testing for electric and electronic products -
Part 2. Test method - Test Cab. Damp heat steady state
GB/T 2423.4 Environmental testing for electric and electronic products -
Part 2. Test method - Test Db. Damp heat, cyclic (12h + 12h cycle)
GB 4208 Degrees of protection provided by enclosure (IP code)
GB 4943.1 Information technology equipment - Safety - Part 1. General requirements
GB/T 9361 Safety requirements for computer field
GB/T 11287 Relays - Part 21. Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section one. Vibration tests (sinusoidal)
GB/T 14537 Shock and bump tests on measuring relays and protection equipment
GB/T 17626.2-2006 Electromagnetic compatibility (EMC) - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques - Radiated radio-frequency electromagnetic field immunity test
GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test
GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge...
GB/T 7600-2014 | DL/T 1498.4-2025 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 2423.1Environmental testing for electric and electronic products - Part 2: Test methods - Tests A: Cold
- GB/T 2423.2Environmental testing for electric and electronic products - Part 2: Test methods - Tests B: Dry heat
- GB/T 2423.3Environmental testing - Part 2: Testing method - Test Cab: Damp heat, steady state
- GB/T 2423.4Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
- GB 4208Degrees of Protection Provided By Enclosure (IP Code)
How to Download DL/T 1498.1-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation.
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4208-1993 — Degrees of protection provided by enclosure (IP code)
GB 4208-2008 — Degrees of Protection Provided By Enclosure (IP Code)
GB 4943.1-2011 — [Replaced by GB 4943.1-2022] Information technology equipment - Safety - Part 1: General requirements
DL/T 1498.1-2016
$115.00