Issued by

Ministry of Housing and Urban-Rural Development of PRC

Level / Type

National · Recommended

Issue date

September 22, 2008

Implementation date

February 1, 2009

Scope

CJ/T 112-2008 (Integrated circuit card diaphragm gas meter) is available as an English-translated PDF.

CJ/T 112-2008 — This standard specifies the technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of IC card diaphragm gas meters with a maximum flow of 160 m3/h.

This standard is applicable to the design, production, testing and acceptance of IC card diaphragm gas meter (hereinafter referred to as gas meter).

Found what you need?

Document preview — CJ/T 112-2008

National Standard of the People's Republic of China

ICS
91.140.99
Classification
P 47

Issued by: Ministry of Housing and Urban-Rural Development of PRC

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and definitions...6
  • 4 Model preparation...7
  • 5 General requirements...7
  • 6 Technical requirements...8
  • 7 Test methods...13
  • 8 Inspection rules...20
  • 9 Marking, packaging, transportation and storage...23

Foreword

This standard shall, from the date of implementation, replace CJ/T 112-2000

"Integrated circuit card diaphragm gas meter for household use".

In the development process, this standard makes reference to EN 1359 "Gas

meter - Diaphragm gas meters". This standard is the revision of CJ/T 112-2000

"Integrated circuit card diaphragm gas meter for household use". As compared

with CJ/T 112-2000, the main changes are as follows.

- ADD the application scope of integrated circuit card diaphragm gas meter;

INCREASE the maximum flow rate from 10 m3/h to 160 m3/h; CHANGE

the standard name into "Integrated circuit card diaphragm gas meter";

- CANCEL the memory card;

- CANCEL the IC card gas meter using AC power supply;

- ADD the service life requirements for built-in battery;

- ADD the appearance requirements for IC card gas meter;

- In the environmental requirements, ADD the requirements for IC card gas

meter storage temperature;

- CHANGE the enclosure protection level from IP31 to IP53;

- ADD the electrostatic protection requirements;

- ADD the quiescent current and maximum operating current requirements;

- ADD the conversion error requirements;

- ADD the security requirements.

This standard was proposed by the Ministry of Housing and Urban-Rural

Development Standard Quota Study Institute.

This standard shall be under the jurisdiction of the Ministry of Housing and

Urban-Rural Development Urban Gas Standard Technical Unit - North China

Municipal Engineering Design and Research Institute.

The main drafting organizations of this standard. Urban Construction Research

Institute, Dandong Sikai Electronic Development Co., Ltd., Zhengzhou Anran

I&C Equipment Co., Ltd., Hangzhou Pioneer Electronic Technology Co., Ltd.,

Shandong Jining Lanwei Intelligent Network Center, Dandong Thermal

Integrated circuit card diaphragm gas meter

1 Scope

This standard specifies the technical requirements, test methods, inspection

rules, marking, packaging, transportation and storage of IC card diaphragm gas

meters with a maximum flow of 160 m3/h.

This standard is applicable to the design, production, testing and acceptance of

IC card diaphragm gas meter (hereinafter referred to as gas meter).

2 Normative references

The provisions in following documents become the provisions of this Standard

through reference in this Standard. For the dated references, the subsequent

amendments (excluding corrections) or revisions do not apply to this Standard;

however, parties who reach an agreement based on this Standard are

encouraged to study if the latest versions of these documents are applicable.

For undated references, the latest edition of the referenced document applies.

GB/T 2423.17 Environmental testing for electric and electronic products -

Part 2. Test method - Test Ka. Salt mist (GB/T 2423.17-1993, eqv IEC

60068-2-11.1981)

GB/T 2828.1 Sampling procedures for inspection by attribute - Part 1.

Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot

inspection (GB/T 2828.1-2003, ISO 2859-1.1999, IDT)

GB/T 2829 Sampling procedures and tables for periodic inspection by

attributes (Apply to inspection of process stability)

GB/T 4208-1993 Enclosure protection class (IP code) (eqv IEC 529.1989)

GB/T 6968 Diaphragm gas meters

GB/T 17626.2-2006 Electromagnetic compatibility (EMC) - Testing and

measurement techniques - Electrostatic discharge immunity test (GB/T

17626.2-2006, IEC 61000-4-2.1995, IDT)

GB/T 17626.3-2006 Electromagnetic compatibility (EMC) - Testing and

measurement techniques - Radiated radio frequency electromagnetic field

immunity test (GB/T 17626.3-2006, IEC 61000-4-3.2002, IDT)

CJ/T 3074-1998 Electronic controller of household gas burning appliances

CJ/T 3075.2-1998 Laboratory of gas burning appliances - Test equipment

and device

JJG 577 Verification regulation of diaphragm gas meter

3 Terms and definitions

The following terms and definitions apply to this standard.

3.1

IC card diaphragm gas meter

It refers to the gas meter which uses the diaphragm gas meter as the basic

gas meter and the IC card as the media and is added with controller, having

the function of gas pre-purchase.

3.2

Basic gas meter

It refers to the diaphragm gas meter used in the IC card diaphragm gas meter.

3.3

Control unit

It refers to the device used to read the basic gas meter data, display and

control.

3.4

Minimum operating voltage

It refers to the minimum set voltage to ensure the normal operation of

controller.

3.5

Total pressure loss

It refers to, after the gas meter is installed with control valve, the pressure

loss between the gas inlet and gas outlet under the specified conditions.

3.6

6.2.1.1 Storage temperature. -25 °C ~ +55 °C, after the restoration of normal

temperature, its function shall comply with the requirements of 6.3 and 6.4.

6.2.1.2 Operating temperature. -10 °C ~ +40 °C, AND its function shall comply

with the requirements of 6.3, 6.4, and 6.6.

6.2.2 Constant heat and humidity

When the relative humidity is 93% and temperature +40 °C, its function shall

comply with the requirements of 6.3 and 6.4, AND the appearance shall be free

from rust.

6.2.3 Salt mist

Gas meter shall have salt mist resistant performance, AND its function shall

comply with the requirements of 6.3 and 6.4.

6.2.4 Vibration

Gas meter shall have anti-vibration performance, the whole machine shall be

free from loosening, AND its function shall comply with the requirements of 6.3

and 6.4.

6.3 Prompt function

Gas meter shall have one or more prompt functions of acoustic, light, and

graphic display.

6.3.1 Under-voltage of operating power

When the gas meter's operating voltage drops to the designed minimum

operating voltage of the product, there will be a clear prompt.

6.3.2 Residual gas volume insufficiency

When the gas meter's residual gas volume drops to the predetermined value,

there will be a clear prompt.

6.3.3 Misoperation

When using other cards than that of this meter OR when there is other

misoperations, there will be a clear prompt.

6.4 Control functions

6.4.1 Gas pre-purchase volume and gas use control.
6.5.3.2 Electrostatic protection

It shall comply with the level 2 requirements of GB/T 17626.2-2006; when the

contact discharge is 4 kV, the gas meter shall automatically close the valve or

operate normally, AND shall comply with the requirements of 6.3 and 6.4.

6.5.3.3 Insensitivity to radiated electromagnetic fields

It shall comply with the level 3 requirements of GB/T 17626.3. when the field

strength is 10 V/m and the frequency is 80 MHz ~ 1000 MHz, the gas meter

shall be automatically close the valve or operate normally, AND shall comply

with the requirements of 6.3 and 6.4.

6.6 Electrical performance

6.6.1 Quiescent current

As for the gas meter using the built-in battery, the quiescent current shall be not

less than 20 µA.

6.6.2 Maximum operating current

The maximum operating current of the gas meter shall be less than 500 mA.

6.7 Valves

6.7.1 Sealability

When the valve is closed and the inlet pressure is 5 kPa, the allowable internal

leakage of the valve shall not be more than 0.55 L/h.

6.7.2 Durability

After respectively opening and closing the valve for 5000 times, it shall operate

normally AND the sealability shall comply with the requirements of 6.7.1.

6.8 Seat durability

After continuously 10000 times of card plugging, its performance shall comply

with the requirements of 6.4.1.

6.9 Pulling resistance of external connection line

When the gas meter has external connection line, under the external force of

30 N, the connection line and the connection part shall not be separated or

deformed.

6.10 Overall sealability

Power supply. voltage 0 V ~ 12 V continuously adjustable AND the output

current is 1 A;

Voltmeter. the range is adapted to the voltage used by the tested gas

meter, AND the accuracy is level 1.

Micro-ammeter. range 50 µA AND accuracy level 1;

Ammeter. range 1 A and accuracy level 1.

7.6.1 Quiescent current

In accordance with the test schematics 3, CONNECT the tested gas meter;

MOVE the switch K to position 3; ADJUST the DC stabilized power supply to

the voltage equivalent to the normal operating voltage of the gas meter; MOVE

the switch K to position 2, to make the gas meter work normally; after the gas...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.

Referenced standards

How to Download CJ/T 112-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
23 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

CJ/T 112-2008

$125.00