Valid

JJG 577-2012Verification Regulation of Diaphragm Gas Meters (English PDF)

Preview PDF

Also coversJJG577-2012

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for JJG 577-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine Verification regulation of diaphragm

Level / Type

National · Mandatory

Issue date

September 3, 2012

Implementation date

March 3, 2013

Scope

JJG 577-2012 (Verification Regulation of Diaphragm Gas Meters) is available as an English-translated PDF.

JJG 577-2012 is the Chinese standard "Verification Regulation of Diaphragm Gas Meters". Its scope clause reads: This regulation is applicable to the first verification, subsequent verification and in-use inspection of diaphragm gas meters (hereinafter referred to as gas meters).

Its clauses include terms and metering units; overview; metrological performance requirements; general technical requirements; metering instrument control. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine Verification regulation of diaphragm on 2012-09-03 and took effect on 2013-03-03.

Found what you need?

Document preview — JJG 577-2012

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine Verification regulation of diaphragm

Contents

  • Introduction...4
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and metering units...5
  • 3.1 Terminology...5
  • 3.2 Unit of measurement...7
  • 4 Overview...7
  • 4.1 Principle and structure...7
  • 4.2 Use...8
  • 5 Metrological performance requirements...8
  • 6 General technical requirements...8
  • 6.1 Nameplates and markings...8
  • 6.2 Appearance...9
  • 6.3 Flow-rate range...9
  • 6.4 Indicating device...10
  • 6.5 Sealing...10
  • 6.6 Pressure loss...10
  • 6.7 Ancillary devices...11
  • 6.8 Safety performance...11
  • 7 Metering instrument control...11
  • 7.1 Verification conditions...11
  • 7.2 Verification item...12
  • 7.3 Verification method...13
  • 7.4 Processing of verification results...18
  • 7.5 Verification cycle...18
  • Appendix A Functional testing of gas meter ancillary device...19

1 Scope

This regulation is applicable to the first verification, subsequent verification and in-use inspection of diaphragm gas meters (hereinafter referred to as gas meters).

2 Normative references

This regulation refers to the following documents.

JJF 1001-2011 General terms in metrology and their definitions

GB/T 6968-2011 Diaphragm gas meters

OIML R137-1&2.2012 Gas meters

OIML D11.2004 General requirements for electronic measuring instruments

EN 1359.1998 + A1.2006 Diaphragm gas meters

For dated references, only the dated version applies to this regulation; for undated references, the latest version (including all amendments) applies to this regulation.

3 Terms and metering units

3.1 Terminology

3.2 Unit of measurement

Volume unit. cubic meter, symbol m3; liter, symbol L; cubic decimeter, symbol dm3.

4 Overview

4.1 Principle and structure

The gas meter is a volumetric gas flow meter that uses a flexible diaphragm metering chamber to measure gas volume flow. Under the action of the pressure difference, the gas is alternately entered into the metering chamber through the distribution valve, and is filled to the gas outlet after being filled fully.

At the same time, the flexible diaphragm in the metering chamber is pushed to reciprocate, and the circulation process of the inflation and exhaust is converted into the corresponding gas volume flow by the conversion mechanism.

4.1.1 Anti-reverse device

The gas meter shall be equipped with means to prevent reversal. When the gas inflow direction is opposite to the specified flow direction, the gas meter shall be able to stop the metering or reverse counting is prohibited.

4.2 Use

The gas meter is mainly used to measure the cumulative volume flow of gas, it is widely used in gas metering applications for civil and industrial and commercial applications.

5 Metrological performance requirements

The accuracy grade of the gas meter is 1.5, the indication error shall meet the requirements of Table 1.

6 General technical requirements

6.1 Nameplates and markings

The nameplate or body of the gas meter shall be marked of the following.

6.2 Appearance

The newly manufactured gas meter outer casing shall be evenly coated, there shall be no blisters, falling off, scratches, etc. Counters and markings shall be legible and mechanical seals shall be sound and reliable. Gas meter operation shall be stable, and it is not allowed to affect the metering performance and obvious intermittent pause.

6.3 Flow-rate range

The flow-rate range value of the gas meter shall comply with the requirements of Table 2.

6.4 Indicating device

The counter shall meet the requirement that the cumulative flow of the gas meter shall work for 6000 hours at the maximum flow-rate without returning to zero.

6.5 Sealing

The gas meter must be tested for tightness and input 1.5 times the maximum operating pressure for a duration of not less than 3 minutes. The gas meter must not leak.

6.6 Pressure loss

The maximum allowable value of gas meter pressure loss shall not exceed the requirements of Table 4.

6.7 Ancillary devices

If the gas meter is equipped with an ancillary device, its metering performance shall meet the requirements of clause 5.The function of the gas meter with ancillary device shall meet the corresponding functional testing requirements in

Appendix A.

7 Metering instrument control

The metering instrument control includes the first verification, subsequent verification and in-use inspection of the gas meter.

7.1 Verification conditions

7.1.5 During the verification process, the difference between the temperature

at the standard device and the temperature at the gas meter (including room temperature, standard device liquid temperature, and verification medium temperature) shall not exceed 1 °C.

7.1.6 The verification medium is generally air.

7.1.7 The verification pressure shall not exceed the maximum operating pressure of the gas meter, and the verification system shall not leak air.

7.2 Verification item

The items for the first verification, subsequent verification and in-use inspection are as shown in Table 6.

7.3 Verification method

7.3.1 Appearance

The appearance of routine inspection of gas meters shall comply with the requirements of 6.1, 6.2, 6.3 and 6.4 of clause 6 "General technical requirements" of this regulation.

7.3.4.5 The arbitration dynamics method is preferred for arbitration verification.

7.3.5 Refer to Appendix A for functional testing of gas meters equipped with

ancillary devices.

7.4 Processing of verification results

The qualified gas meter shall be issued with the verification certificate or attached with the verification qualified mark (or seal mark); the unqualified gas meter shall be issued with the verification result notice, and the unqualified item shall be indicated.

7.5 Verification cycle

7.5.1 For the maximum flow-rate qmax <= 10 m3/h and the gas meter used for trade settlement, only the first mandatory verification is performed, it is used within the specified time period, and replaced when it is expired.

7.5.2 For the gas meter with a maximum flow-rate qmax >= 16 m3/h, the calibration cycle is generally not more than 3 years.

Appendix A

Functional testing of gas meter ancillary device

For gas meters equipped with ancillary devices, it is necessary to perform tests in accordance with the product specifications and the functions that the product can achieve (without destroying the seal).

A.1 Functional testing can be performed under non-calibrated conditions. The gas meters with ancillary devices shall generally have the following prompt functions.

A.1.1 Operating power supply undervoltage

When the gas meter operating power supply is under voltage, it shall have clear text symbol, sound and light alarm, close control valve and so on.

A.1.2 Mis-operation

When the gas meter encounters an incorrect operation, it shall be prompted by one or more ways, such as text symbol, sound and light alarm, to close the control valve or maintain the original operating state.

A.2 Gas meters with pre-payment functions must have the following control functions.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

How to Download JJG 577-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJG 577-2012

$60.00