YY/T 1542-2017 is the English-translated version of 数字化医用X射线设备自动曝光控制评价方法.
YY/T 1542-2017 is the Chinese pharmaceutical industry standard that gives the method for evaluating the automatic exposure control of digital medical X-ray equipment, the circuit that ends the exposure when the detector has received enough radiation.
It sets out the phantoms and the beam qualities, the measurements of the resulting detector dose and image, and the criteria by which the consistency of the control across thicknesses, tube voltages and fields is judged.
Equipment with other kinds of automatic control may use it as a reference. Issued on 2 May 2017, it has applied since 1 April 2018.
Found what you need?
Document preview — YY/T 1542-2017
National Standard of the People's Republic of China
- ICS
- 11.040.50
- Classification
- C 43
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions GB/T 10149-1988 defined and the following
- 4 Evaluation Method Overview
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the digital medical X-ray device automatic exposure control evaluation method.
This standard applies to digital X-ray equipment automatic exposure control evaluation, the use of other methods of X-ray automatic control system X-ray equipment can refer to this evaluation method.
This standard does not apply to breast X-ray equipment, radiotherapy simulation equipment, computer tomography equipment and panoramic dental X-ray equipment.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB 9706.3-2000 Medical electrical equipment - Part 2 - High-voltage generators for diagnostic X-ray generator safety-specific requirements Medical X - ray equipment - Terms and symbols
3 Terms and definitions GB/T 10149-1988 defined and the following
terms and definitions apply to this document.
3.1 Automatic control system
In an X-ray apparatus, the power supplied to the X-ray tube assembly is measured by one or several doses of radiation or corresponding physical quantities Control or limit the system.
3.2 Automatic Exposure Control automaticexposurecontrol; AEC
In X-ray equipment, one or more loading factors are automatically controlled to obtain the desired mode of radiation at the preselected location formula. Automatic exposure control is also known as automatic exposure control.
3.3 Automatic exposure rate control
In X-ray devices, the radiation dose rate is automatically controlled by the control of one or more loading factors so that, at the preselected location and The mode of operation to obtain the desired amount of radiation for a predetermined loading time.
3.4 Automatic intensity control
In X-ray equipment, one or more loading factors are automatically controlled in order to obtain the desired radiation dose rate at a pre-selected location mode.
4 Evaluation Method Overview
4.1 The general conditions to be considered in the evaluation
The purpose of this evaluation method is to demonstrate that the specified characteristics of the equipment are within specified tolerances and that some of the requirements are compulsory by law and others
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Normative references
GB 9706.3-2000
Similar standards
How to Download YY/T 1542-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 1542-2017
$269.00