YY/T 1429-2016Implants for surgery—Acrylic resin cement—Flexural fatigue testing of acrylic resin cements used in orthopaedics (English PDF)
外科植入物丙烯酸类树脂骨水泥矫形外科用丙烯酸类树脂骨水泥弯曲疲劳性能试验方法
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1429-2016 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
January 26, 2016
Implementation date
January 1, 2017
Scope
YY/T 1429-2016 is the English-translated version of 外科植入物丙烯酸类树脂骨水泥矫形外科用丙烯酸类树脂骨水泥弯曲疲劳性能试验方法.
YY/T 1429-2016 is the Chinese pharmaceutical industry standard that describes how the flexural fatigue of acrylic resin bone cement is tested, the cement based on polymethacrylate that fixes an implant to bone.
It gives an overview of the test method, the equipment required, the selection and preparation of the specimens, the test procedure step by step and what the test report must contain, with the cement itself specified in YY 0459 and the test solutions and environmental conditions taken from the ISO work on implant materials.
It does not deal with the hazards to the patient or to the user arising from the use of bone cement. Issued on 26 January 2016, it has applied since 1 January 2017.
Found what you need?
Document preview — YY/T 1429-2016
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C 35
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Overview of test methods
- 5 sample selection and preparation
- 6 Test Step
- 7 Test Report
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the translation method equivalent to ISO 16402.:2008 "Surgical Implants Acrylic Resin Bone Cement Orthopedic Surgery C Standard Test Method for Bending Fatigue Performance of Acrylic Resin Bone Cement ". For ease of use, this standard has been modified as follows.
--- in accordance with the Chinese language used to modify some of the format;
--- to some of the statements applied to international standards to apply to the formulation of our standards;
--- will be Chapter 2 "normative reference document" has been converted into national standards instead of using national standards.
And the normative reference in this standard international documents are consistent with the relationship between China's documents are as follows.
1 Scope
This standard applies to polymethacrylate-based resinous bone cement, and detailed description of the polymerization of bone cement fatigue properties Of the test steps.
This standard does not cover the hazards of patients or bone cement users when using bone cement.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
YY 0459-2003 Surgical Implants Acrylic Resin Bone Cement (ISO 5833.:2002, IDT)
ISO 16428 Surgical implants - Determination of open-circuit potentials for the evaluation of corrosion characteristics of metal implants and medical equipment after extension Method (Implantsforsurgery-Testsolutionsandenvironmentalconditionsforstaticanddynamiccorro- siontestsonimplantablematerialsandmedicaldevices)
3 Overview of test methods
The test uses rectangular strip samples. See Chapter 5 for the preparation of the sample.
The bending strength of the specimen is obtained by a four-point bending test under quasi-static or periodic load conditions. Under the conditions of the cycle load introduced two Method. The first method follows the Wöhler theory (S/N curve method), which determines the bending properties in the case of full stress. Second Method (low stress method) Determines the bending characteristics only at lower stress conditions. In clinical applications it is possible to encounter these specific low stresses Happening.
4 Equipment
4.1 Equipment for mixing bone cement, recommended by bone cement manufacturer.
4.2 mold, with the appropriate material made of mold, the sample processing growth 75mm, 10mm wide and 3.3mm high rectangular test strip. and also The mold can be made into a 3.3 mm sheet with a thickness of 3.3 mm and cut into the size of the test strip. All molds in contact with bone cement With a surface application of 400 mesh sandpaper for grinding.
Note. There can be a certain degree of stiffness of the metal materials, such as aluminum or stainless steel.
4.3 Smooth plate, prepared from a suitable material (two for each mold), shall be sufficient to cover the upper and lower surfaces of the mold as described in Section 4.2.
4.4 release agent, easy to sample and mold separation.
Note. can be used PTFE spray, vacuum grease or beeswax and so on.
4.5 polyester film, covering the mold plate.
4.6 C-clamp or other device that can clamp the mold between the upper and lower plates.
4.7 bending test equipment, can be applied to reach.200N load, can be applied between the 0N to set the value of the linear or sinusoidal cycle of the load
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1429-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY 0459-2003 — Implants for surgery—Acrylic resin cements
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field