YY/T 1281-2015Dentistry—Implants—Clinical performance of hand torque instruments (English PDF)
牙科学 种植体 手动扭矩器械的临床性能
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1281-2015 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
March 2, 2015
Implementation date
January 1, 2016
Scope
YY/T 1281-2015 is the English-translated version of 牙科学 种植体 手动扭矩器械的临床性能.
YY/T 1281-2015 is the Chinese pharmaceutical industry standard for the hand torque instrument used with dental implants, the manual torque wrench with which an implant component is tightened to a set value.
It describes the clinical classification of these instruments and sets the performance requirements for them, among them the accuracy of the torque delivered, the repeatability, the stability of the value over repeated use and after cleaning and sterilization, together with the test methods and the information supplied. Issued on 2 March 2015, it has applied since 1 January 2016.
Found what you need?
Document preview — YY/T 1281-2015
National Standard of the People's Republic of China
- ICS
- 11.060.10
- Classification
- C 33
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with ISO 11953:2010 "Clinical Evaluation of Implant Dentistry hand torque instruments." Correspondence between the consistency of the standards of international documents and normative references of the following documents.
--- GB/T 9937 (all parts) oral vocabulary [ISO 1942 (all parts)]
Introduction
Screw connection dental implant system widely used dental implant system relies screw connection produced and maintained appropriate Fastening force as a whole. Screw connection failure is a clinical problem has been disclosed, it would have a significant impact on treatment outcome.
In the implant treatment process, to tighten the screws, widely used in the appropriate range of hand torque wrench or appliance, such a device should always be able to provide treatment Think of torque. However, there is evidence that is not the case. Therefore, in order to promote compliance with the requirements of clinical instrument applications, help ensure Paul clinical success, formulated standards. Implant dentistry hand torque instruments Clinical Performance
1 Scope
This standard clinical classification manual torque wrench has been described. It provides for its accuracy, repeatability and stable reuse Qualitative and other performance requirements.
The standard test methods are described, it specifies the requirements for marking and labeling. This standard does not include an electronic control device.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO 1942 (all parts) oral vocabulary (Dentistry-Vocabulary)
Reusable sterile medical devices Disposal Information ISO 17664 medical device sterilization manufacturer (Sterilizationofmedical devices-Informationtobeprovidedbythemanufacturerfortheprocessingofresterilizablemedical devices)
3 Terms and Definitions
As defined in ISO 1942 and the following terms and definitions apply to this document.
3.1 Hand Torque instrument
Manually operated mechanical device, or by displaying the torque limiting device for tightening a dental implant or dental implant system Part.
3.2 Use usage
In accordance with the manufacturer's instructions, by reassembling (including dismantling, cleaning, disinfection and/or sterilization) after the order be tightened and re-tighten the operation. Category 4
4.1 General
Screw connection is produced by the tension caused by the screw fastening force is obtained, the fastening force of each screw has an optimum value.
With manual torque wrench with screw devices, is in torque control method for a dental implant treatment is widely used. The mechanism through
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 1942
Similar standards
How to Download YY/T 1281-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0463-2026 — Dentistry - Refractory investment and die materials
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 1281-2015
$145.00