Valid

YY/T 1025-2014Intra-uterine suction curettes (English PDF)

流产吸引管

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1025-2014 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

June 17, 2014

Implementation date

July 1, 2015

Scope

YY/T 1025-2014 is the English-translated version of 流产吸引管.

YY/T 1025-2014 is the Chinese pharmaceutical industry standard for the metallic intra-uterine suction curette, the cannula fitted to an aspirator to evacuate the uterus in early pregnancy.

It specifies the structural type and the material, the requirements, the test methods, the inspection rules, the marking and the rules for packaging, transport and storage, covering the dimensions and the aperture, the smoothness of the tip and the edges, the strength of the tube and of its connection, the corrosion resistance and the ability of the instrument to be cleaned and sterilized. Issued on 17 June 2014, it has applied since 1 July 2015.

Found what you need?

Document preview — YY/T 1025-2014

National Standard of the People's Republic of China

ICS
11.200
Classification
C 36
Replacing
YY/T 1025-2004

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Structure type and material

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

Instead of the standard YY/T 1025-2004 "abortion suction tube." This standard YY/T 1025-2004 main technical differences are as follows.

--- Modify the scope, defining this standard applies to metallic material abortion suction tube (see Chapter 1);

--- Modify the reference standards and standard reference year (see Chapter 2);

--- Modify the size requirements, only the main parts of a predetermined size (see Table 1);

--- Increasing the dual-chamber type suction tube head and the body of the tube offset distance (see Figure 2);

--- Increase the range of materials suitable for stainless steel (see Table 2);

--- Increasing the suction pipe welding firm requirements and corresponding test methods (see 4.3 and 5.3);

--- Increased corrosion resistance requirements and corresponding test methods (see 4.5 and 5.5).

--- Modify the coating requirements (see 4.6);

1 Scope

This standard specifies the abortion suction tube structure type and material requirements, test methods, inspection rules, marking, packaging, transportation and storage.

This standard applies to metallic material abortion suction tube (hereinafter referred to as the suction pipe). The product is mounted on abortion sucker for early pregnancy Pregnant pregnant woman an abortion surgery.

Note: Some aspects of this standard may be suitable for one-time use abortion suction tube.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 1220 stainless steel rods

GB/T 1527 copper and copper alloy tube drawing

GB/T 2828.1 Sampling procedures for inspection - Part 1.

GB/T 2829 Periodic inspection Sampling procedures and tables (suitable for process stability test)

GB/T 4423 copper and copper alloy rod drawing Reviews on the cover layer thickness measurement GB/T 6463 Metallic and other inorganic

GB/T 10610 Geometrical product specifications (GPS) Surface texture Profile method - Rules and procedures for evaluation of the surface structure

YY 0076-1992 metal parts coating technology classification conditions

YY/T 0149-2006 stainless steel medical equipment corrosion test methods

YY/T 1052 surgical instruments logo

3 Structure type and material

3.1 The Structure Types and basic dimensions

3.1.2 than double lumen suction tube fine narrow chamber with a large area of the chamber should be 1.7 or ~ 8.

3.1.3 suction tube structure types and basic dimensions shall comply with the requirements 1 and 2 of Table 1 and Fig.

3.1.1 suction tube into a single cavity and dual-chamber type

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY/T 1025

EditionTitleRevisionStatus
YY/T 1025-2014Intra-uterine suction curettescurrent editionCurrent
YY/T 1025-2004Intra-uterine suction curettesprevious editionSuperseded

This page sells the current edition, YY/T 1025-2014. Earlier editions are listed for reference only.

How to Download YY/T 1025-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1025-2014

$125.00