YY/T 0968.1-2014Medical optical radiation protective eyewear - Evaluation method - Part 1: Degree of optical radiation hazard reduction (English PDF)

医用光辐射防护镜 评价方法 第1部分:光辐射危害降低程度

Open the YY/T 0968.1-2014 preview as PDF

Preview — first pages of YY/T 0968.1-2014 (full document: 15 pages)

This is a limited preview

Buy now to download the full PDF (15 pages)

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

June 17, 2014

Implementation date

July 1, 2015

Scope

YY/T 0968.1-2014 is the English-translated version of 医用光辐射防护镜 评价方法 第1部分:光辐射危害降低程度.

YY/T 0968.1 is the method for measuring how much protection medical optical radiation eyewear actually gives. It is Part 1 of the Chinese series on evaluating such eyewear and covers the degree to which the optical radiation hazard is reduced: the attenuation the filter provides at the wavelengths that matter, and how that attenuation holds up under the exposure conditions the eyewear is meant for. Protective eyewear in surgical lasers, phototherapy and dental curing is the last barrier between a source and a retina, and a filter that is nominally right for a wavelength but wrong for the power density is a hazard disguised as a control. Part 2 covers what the wearer can still see. For a manufacturer of medical protective eyewear for China, this is the standard behind the protection rating.

Document preview — YY/T 0968.1-2014

National Standard of the People's Republic of China

ICS
11.040.70
Classification
C40

Issued by: National Medical Products Administration

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

YY/T 0968 "Evaluation of medical optical radiation goggles" is divided into two parts.

--- Part 1. reduce the degree of optical radiation hazard;

--- Part 2. Vision that vision and color vision. This section YY/T Section 10968 of. This section drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by the China Food and Drug Administration. This part of the National Medical Optics Instrument Standardization Technical Committee (SAC/TC103/SC1) centralized. This section drafted by: State Food and Drug Administration Hangzhou Medical Device Quality Supervision and Inspection Center, Zhejiang Medical Devices Unit The inspection. The main drafters of this section. JIA Xiao Hang, Wang Jingtao Huang precisely, Wen Yan. Medical optical radiation goggles Evaluation Method Part 1. reduce the degree of optical radiation hazard

1 Scope

YY/T 0968.1 is the method for measuring how much protection medical optical radiation eyewear actually gives. It is Part 1 of the Chinese series on evaluating such eyewear and covers the degree to which the optical radiation hazard is reduced: the attenuation the filter provides at the wavelengths that matter, and how that attenuation holds up under the exposure conditions the eyewear is meant for. Protective eyewear in surgical lasers, phototherapy and dental curing is the last barrier between a source and a retina, and a filter that is nominally right for a wavelength but wrong for the power density is a hazard disguised as a control. Part 2 covers what the wearer can still see. For a manufacturer of medical protective eyewear for China, this is the standard behind the protection rating.

YY/T 0968 provisions of this part of the optical radiation hazards of medical optical radiation goggles minimize evaluation methods. This section applies to regular wear protective glasses medical optical radiation. This section does not apply to medical lasers and beam diameter smaller than the eye pupil class under a light source of optical radiation goggles.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 20145-2006 lamps and lamp systems light biosafety (CIE009S/E.2002, IDT)

ISO 15004-2.2007 ophthalmic instruments basic requirements and test methods - Part 2. Light hazard protection (Ophthalmicinstru- ments-Fundamentalrequirementsandtestmethods-Part 2. Lighthazardprotection)

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Treatment tool processingdevice By the use of specific processing technology to achieve the desired spectral transmission of the spectral distribution of the optical instrument.

3.2 Original appliance primarydevice Over the substrate processing apparatus, with the processor having the same shape. The appliance is a matte absorption and a refractive index in the evaluation of the spectrum The ideal instrument constant.

3.3 Spectral transmittance spectraltransmittance tau (lambda) Natural light conditions at normal incidence, the spectral radiant flux transmitted through phietlambda () of the incident spectral radiant flux phieilambda () ratio. See Calculation Formula (1). tau (lambda) = phiet lambda () phieilambda () × 100% = Deltaphielambdat Deltaphielambdai × 100% (1) Where. Deltaphielambda

--- wavelength spacing (bandwidth) Deltalambda corresponding radiant flux (subscript t represents radiant flux permeable, it represents the incident radiation through Volume), Deltaphielambda = phielambda () · Deltalambda.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

YY/T 0932|YY/T 0940|YY/T 0943|YY/T 0764|YY/T 0984|YY/T 0955

How to Buy YY/T 0968.1-2014

  1. 1Add to cart. Click the "Buy YY/T 0968.1-2014" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0968.1-2014

$130.00

$110.00for partners